Installation
1)
2)
Important Information
*
*
Brazed connections should not be made directly onto
the mixer, as excessive heat will coause permanant damage.
Attach inwall body mounting box (11) to timber noggins
as shown (Fig.3) using the 6 off supplied screws (1). Use
the integrated level indicator (2) to ensure that the box
is mounted horizontally.
Remove cover (3) by unscrewing the 4 off plastic
socket screws (4) using the supplied spanner.
3) Remove sealing grommet (5). Insert DN15
copper mains supply pipe through grommet,
and then insert pipe into box. Assemble compression
fitting and make connection with the G1/2 integrated
isolation valve (6). After connection has been made,
slide sealing grommet back onto mounting box. Ensure
that the isolation valve (7) is in the CLOSED POSITION
as shown (Fig.1). Open mains supply & check for leaks.
Connect power supply (8) to a 240VAC, 10A GPO.
Ensure that supply of power has been isolated.
The power outlet should be located no more
than 2.2m from the inwall body box when using the
supplied extension cable (9).
Connection points (10) are provided for terminating standard
20mm electrical conduit to the mounting box.
Run cable through connection points and into the mounting box .
Once inwall body installation has been completed,
replace & secure mounting box cover (3) using
screws (4). Complete lining & tiling process. After
tiling is complete, trim excess mounting box tiling
flange so that it flush with the finshed surface (Fig.2).
Re-attach mouting box cover (3) using the screws (4).
4)
5)
All pipework must be throroughly flushed prior to installation.
Refer to side 2 of this instruction for trim kit installation.
*
PLUMBERS INSTALLATION INSTRUCTIONS - INWALL BODY (99098)
ELECTRONIC WALL MOUNTED TAP
WATER EFFICIENT - CONNECTED TAPWARE ENABLED BY AWARETM
5
8
3
41
11
Fig. 3
9
92
194
12 6
10 7
5
Fig. 1
B
30
55-75
20
92 +5
0
Trim excess mounting
box tiling flange after
tiling to be flush with surface.
Fig. 2
Detail B
Isolation Valve in
closed position
Maximum hot water temperature : 80 C.
IMPORTANT
Pressure & Temperature Requirements.
New Regulation :-500 kPa maximum static pressure
at any outlet within a building. (Ref. AS/NZS 3500.1)
Static inlet pressure range : 50 -700 kPa
Installation Requirements.
The installing plumber is responsible for waterproofing
all penetrations for Taps in Shower areas at installation
by a proprietary flange system or a sealant.(Ref AS3740)
PLUMBERS INSTALLATION INSTRUCTIONS - TRIM KIT (98451C6A)
WATER EFFICIENT - CONNECTED TAPWARE ENABLED BY AWARE
ELECTRONIC WALL MOUNTED TAP
IS1682C(08/18)
Sheet 2 of 2
1)
6)
2)
3)
4)
5)
7)
8)
9)
Remove mounting box cover: Using a 6mm allen key, remove cover retaining screws (6)
and cover (5). Ensure that isolation valve is still in the closed position.
Remove solenoid blanking plug and attach solenoid (1). Note: Lightly tighten
only (1 Nm). Open the isolation valve and check for leaks.
Align & attach outlet spout assembly (2) to outlet spigot (3) with retaining
nut (4), ensuring cables do not become jammed or damaged.
Connect Cables:
(Green + Yellow) to solenoid
(Brown + White) to blue module
Power supply cable to blue module.
Secure cables using the integrated retaining features.
Slide backing plate (5) over spout assembly and attach to mounting box by
re-using the 4 off plastic cover retaining screws (6).
DO NOT OVERTIGHTEN.
Note: Backing plate has integrated gasket to seal against the tile surface.
Slide fascia plate (7) over spout and attach to backing plate. The fascia plate
is attached by lifting slightly (approx 2mm) to allow the mounting tags to
engage. Drop the plate and press down lightly to engage with backing plate.
Slide the rubber seal (8) over the spout and press into facsia plate firmly.
Slide cover ring (9) and push firmly against the fascia plate.
Secure grub screw with 2mm allen key underneath.
Installation
10)Commisioning Procedure:
a) Power on the device at the GPO and allow the unit to
complete the calibration sequence as follows:
1) The indicator LED will flash, then allow a small amount of
water to flow to wet surfaces under sensor.
2) The unit will then perform another calibration on the wet surface
and flush again.
3) The indicator LED will then flash for 30 seconds and then stop.
4) The unit is now ready to operate.
b) Test operation by placing hands under the sensor (within 100mm from Spout).
Water should flow within 0.5 seconds.
Remove hand and the water supply should stop within 2 seconds.
IMPORTANT: Please refer to AWARE operation manual (IS 1683) to configure
wireless communication and change the device default settings.
13
4
5
6
7
8
9
TM
Fig. 4
2
IMPORTANT
It is the installers responsibility to ensure the
installation complies with AS/NZS3500.1,
AS/NZS3500.2, AS/NZS3500.4.1, AS/NZS3500.4.2
and local water authority regulations.
Refer to side 1 of this instruction for in-wall body installation.
Important Information
Not suitable for gravity feed systems.
*
*
All pipework must be thoroughly flushed prior to installation, as foreign materials
may block the flow regulating device and reduce the flow of water. Note: Aerator
insert must be retightened to prevent removal by hand.
*
Wall outlet is fitted with a flow regulated aerator insert. This low flow rate may not be
suitable for connection to some Instantaneous Gas Water Heaters, some Tempering
Valves, some Solar Water Heaters & some Thermostatic Mixing Valves.
Check with the manufacturers of these products.

Other Caroma Kitchen & Bath Fixture manuals

Caroma Nordic 90950c User manual

Caroma

Caroma Nordic 90950c User manual

Caroma SKANDIC User manual

Caroma

Caroma SKANDIC User manual

Caroma E Touch G Series User manual

Caroma

Caroma E Touch G Series User manual

Caroma G Series User manual

Caroma

Caroma G Series User manual

Popular Kitchen & Bath Fixture manuals by other brands

VALVEX VEGANE 2422810 Instructions for assembly and use

VALVEX

VALVEX VEGANE 2422810 Instructions for assembly and use

Oras Safira 1340U Installation and maintenance guide

Oras

Oras Safira 1340U Installation and maintenance guide

Hans Grohe Metris 31042009 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Metris 31042009 Instructions for use/assembly instructions

VADO Edit EDI-100M/SB-CP Instruction booklet

VADO

VADO Edit EDI-100M/SB-CP Instruction booklet

KWC EXOS EXOS605X Installation and operating instructions

KWC

KWC EXOS EXOS605X Installation and operating instructions

KWC ZOE TLP 10.201.242.000 Installation and service instructions

KWC

KWC ZOE TLP 10.201.242.000 Installation and service instructions

Hans Grohe 13622180 Assembly instructions

Hans Grohe

Hans Grohe 13622180 Assembly instructions

Kohler Components K-77987-CP Installation and care guide

Kohler

Kohler Components K-77987-CP Installation and care guide

MAINLINE 211E-PUCP Installation

MAINLINE

MAINLINE 211E-PUCP Installation

Pfister Hanover F529-7TM installation guide

Pfister

Pfister Hanover F529-7TM installation guide

Billi Quadra user guide

Billi

Billi Quadra user guide

Helvex E-309 installation guide

Helvex

Helvex E-309 installation guide

Moen TS6520 quick start guide

Moen

Moen TS6520 quick start guide

Kohler LOURE 97909T-4 installation instructions

Kohler

Kohler LOURE 97909T-4 installation instructions

Pegasus 67113-8024H installation instructions

Pegasus

Pegasus 67113-8024H installation instructions

Moen Show House TS3490 manual

Moen

Moen Show House TS3490 manual

Brizo Litze 64043LF Series manual

Brizo

Brizo Litze 64043LF Series manual

Grohe Minta 32 917 manual

Grohe

Grohe Minta 32 917 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.