casmar WS-5446-I User manual

■
for reference purpose.
Please read this instruction carefully for correct use of the product and preserve it
for reference purpose. There may be several technically incorrect places or printing
errors in this manual. The updates will be added into the new version of the manual.
The contents of this manual are subject to change without notice.
Please read this instruction carefully for correct use of the product and preserve it
■
HD Network Dome Camera
Quick Start Guide

1
8
910
RESET
TF
LINKDC IN
CVBS
1
2
3
4
5
6
7
(Fig 2-1)
1 Package
After you receive your device, please check the following accessories.
The pictures here are for reference only.
Camera Screwdriver Water-proof
Cap
CVBS
IN Cables
& DC
Quick Start
Guide CD Drill
Template
Screws &
Spiles
2 Overview
Microphone Cable
Headphone Cable TF Card Slot
Reset Hole
CVBS/DC IN port for testing
Alarm Input/Output
RS485 Cable
Video Output
Network Cable
Power Cable
1
2
3
5
7
9
4
6
8
10

2
◆ Alarm Connection
Alarm Input: There is one independent alarm input port (ALM-IN) and one
grounding port (ALM-GND).There are no type requirements for sensors.
NO and NC are both available.
Join the grounding ends of the sensor and the camera and then connect the
signal cable of the sensor to the alarm input port of the camera.
Alarm Output: There is 1 CH alarm output including COM and NO connections.
Loosen the screws in the alarm output port. Then insert the signal wires of
the alarm output devices into the port of NO and COM separately. Finally
tighten the screws. Some of the external alarm output devices need the
power supply.
◆ RS 485 Connection
You can control the speed dome by RS485 interfaces.
3 Connections
Router
Computer
Network Cable
Network Cable
Network Cable
Network Cable
Network Cable
Modem
Internet
MIC IN
Headphone
DC12V
ALM-COM
ALM-NO
ALM-IN
ALM-GND
RS485T+
RS485T-
(Fig 3-1)

3
123
① Loosen the screws to open the lower dome and then loosen the lock screw
to remove the mounting base.
◆ Ceilling Mounting
Lock Screw
◆ Network Cable Connection
(Fig 3-2)
(Fig 4-1)
4 Installation
withstand 3 times the weight of the camera. Please install and use the camera
in the dry environment. You'd better install back the lower dome less than 4
hours after removing it. The mounting steps are as follows:
Before start, please make sure that the wall or ceiling is strong enough to

4
(Fig 4-2)
(Fig 4-3)
(Fig 4-4)
② Attach the drill template to the place where you want to fix the camera
and then drill 4 screw holes and 1 cable hole (if you want to route the cables
through the mounting base) according to the drill template.
③Route the cables and connect these cables.
base to the ceiling or wall with screws.
And then secure the mounting
④ Fix the camera to the mounting base with the lock screw.

Zoom
Focus
Rotation 0°~360°
Pan 0°~360°
Tilt 0°~77°
5
◆ Pendent Mounting
Pendent mounting
bracket (I)
⑤ Three-axis adjustment. Before adjustment, preview the image of the camera
on a monitor and then adjust the camera according to the figure below to get an
optimum angle.
⑥ Adjust the Focus and Zoom screw to get a clear image (if the model don’t support
this function, please skip this step).
(Fig 4-5)
(Fig 4-6)
⑦ Install the lower dome back to the camera with the screws and remove the
protection film softly to complete the installation.
Pendent mounting
bracket (II)
① Loosen the screws to open the lower dome and then loosen the lock screw
to remove the mounting base as shown in Fig 4-1.
② Secure the pendent mounting bracket to the ceiling and then fix the
mounting base to the pendent mounting bracket with the screws.

6
③Route the cables and connect these cables. fix the camera to the
mounting base with the lock screw.
Then
(Fig 4-7)
(Fig 4-8)
④ Adjust the view angle and the Focus and Zoom screw of the camera
according to the Fig 4-5 to get an optimum angle and clear image.
⑤ Install the lower dome back to the camera with the screws and remove the
protection film softly to complete the installation.

◆ Wall Mounting
7
(Fig 4-9)
(Fig 4-10)
④ Adjust the view angle and the Focus and Zoom screw of the camera
according to the Fig 4-5 to get an optimum angle and clear image.
⑤ Install the lower dome back to the camera with the screws and remove the
protection film softly to complete the installation.
① Loosen the screws to open the lower dome and then loosen the lock screw
to remove the mounting base as shown in Fig 4-1.
② Secure the pendent mounting bracket to the ceiling and then fix the
mounting base to the pendent mounting bracket with the screws.
③ Route the cables and connect these cables. Then fix the camera to the
mounting base with the lock screw.
Here we only take the following wall mounting bracket for example.

8
① Make sure that the camera and the PC are well connected to the LAN.
② Find the IP-Tool from the CD and then install it in the computer. After
that, run the IP-Tool as shown below.
►Access the camera through IP-Tool
5 IE Network Connections
Here we take accessing IP camera via LAN for example. In LAN, there
are two ways to access. 1. Access through IP-Tool; 2. Directly Access
through IE Browser
③ Modify the IP address. The default IP address of this camera is
192.168.226.201. Click the information of the camera listed in the above
table to show the network information on the right hand. Modify the IP
address and gateway of the camera and make sure its network address is
in the same local network segment as the computer’s. Please modify the
IP address of your device according to the practical situation.
Device Network Search
Immediate Refresh
name
name
name
IPC
IPC
IPC
unknown
unknown
unknown
192.168.226.201
192.168.1.2
192.168.1.3
80
80
80
9008
9008
9008
255.255.
255.255.
255.255.
Modify Network Parameter
Mac Address
IP Address
Modify
CE :98 :23 :75 :35 :22
192 . 168 . 226 . 201
255 . 255 . 255 . 0
192 . 168 . 226 . 1
i
Tip: Enter the administrator password, and
then modify the network parameters.
Total Device: 3
Local IP Address:192.168.1.4Subnet Mask:255.255.255.0 Gateway: 192.168.1.1 DNS:210.21.196.6
Device Name Device Type IP Address Http Port Data Port Subnet
Product Model
About
Subnet Mask
Gateway
Restore IPC Default Configuration

9
Mac Address
IP Address
Modify Network Parameter
Modify
CE :98 :23 :75 :35 :22
192 .168 . 1 . 201
255 . 255 . 255 . 0
192 .168 . 1 . 1
Subnet Mask
Gateway
For example, the IP address of your computer is 192.168.1.4. So the IP
address of the camera shall be changed to 192.168.1.X.
After modification, please input the password of the administrator and click
“Modify” button to modify the setting.
The default password of the administrator is 123456.
④ Double-click the IP address and then the system will pop up the IE
browser to connect IP-CAM . IE browser will automatically download the
Active X control. After downloading, a login window will pop up. Input the
user name and password to login.
The default user name is admin; the default password is 123456.
► Directly Access Through IE
The default network settings are as shown below:
IP address: 192.168.226.201 HTTP:80
Subnet Mask: 255.255.255.0 Data Port:9008
Gateway: 192.168.226.1
You may use the above default settings when you log in the camera for
the first time.

10
① Set the IP address of the PC and make sure the network segment should be
as the same as the default settings of the IP-CAM. Open the network and share
center. Click “Local Area Connection” to pop up the following window.
Select “Properties” and then select Internet protocol according to the actual
situation (for example: IPv4). Next, click “Properties” button to set the
network of the PC.
② Open the IE Browser and input the default address of IP-CAM and
confirm. The IE browser will download Active X control automatically.
③ After downloading Active X control, the login dialog box will pop up.
④ Input the default username and password and then enter to view.

450043000235 A0
Table of contents