KBolt Interlock
User Manual - Original Language Version
While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission.
Castell Safety International Limited reserves the right to alter speci cations and introduce improvements without prior notice.
3 of 5
www.castell.com
U-K-001-E Issue 1
Technical Data
Temperature rating Minimum: -40°C [-40°F] ice free for Q & FS Type
Maximum: 107°C [224,6°F] for Q Type/140°C [284°F] for FS Type
Type of mounting M8 (brass), Ø8,35mm (stainless steel), Ø10,3mm (US standard brass/stainless steel)
Weight Brass: 0,7 kg
Stainless steel: 0,7 kg
Material Brass/Stainless steel
MTTF Certifi cation Available on request
We, the manufacturers, declare that the components, detailed herein and placed on the market, comply with all the essential
health and safety requirements applying to them.
Empowered signatory:
Mr T.C. Whelan
Managing Director
EC-Declaration
Application
The power supply to the system is switched on and the
access doors to the hazardous area are locked closed.
Key A is trapped in the disconnector K Lock while the
process is on.
To enter the area, the disconnector is turned to the off
position and key A is released, locking the disconnector
in the disengaged position.
Key A is then taken to the grounding switch. Key A
enters the K lock which retracts the bolt enabling the
cammed switch lever to be rotated to engage the
ground. Once rotated, the recess in the cam aligns with
the second K lock. Key B from the second K lock can
now be removed which now locks the lever in place en-
suring that the ground connection cannot be broken.
Now that the system is disconnected and grounded, key
B can be released to operate the access interlock and
gain access to the dangerous area.
Disconnector ON
Disconnector OFF
Ground ON
Ground OFF
A
A
BB
C