manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Chamberlain
  6. •
  7. Rack & Stand
  8. •
  9. Chamberlain LiftMaster CSW200UL Series User manual

Chamberlain LiftMaster CSW200UL Series User manual

Other manuals for LiftMaster CSW200UL Series

3

This manual suits for next models

2

Other Chamberlain Rack & Stand manuals

Chamberlain FOHMODDC User manual

Chamberlain

Chamberlain FOHMODDC User manual

Chamberlain 195LM User manual

Chamberlain

Chamberlain 195LM User manual

Chamberlain Liftmaster Elite Series User manual

Chamberlain

Chamberlain Liftmaster Elite Series User manual

Chamberlain MRIN User manual

Chamberlain

Chamberlain MRIN User manual

Chamberlain CAPXSGNB User manual

Chamberlain

Chamberlain CAPXSGNB User manual

Chamberlain 480LMC User manual

Chamberlain

Chamberlain 480LMC User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Top View of Type 3
Side View of Type 3
Front
Front
22”
2”
19 1/
4”
Weld Completely
around posts
W4
OFF
ON
© 2004 The Chamberlain Group, Inc.
All Rights Reserved
®
™
4“ Square Posts welded on Inside
Type 3
4“ O.D. Heavy Walled
Square Posts
Not Provided
Model # MPEL
For Technical Support
and Ordering Parts:
1-800-528-2806
Top View of Typical
Standard Installation
35.5"
46"
29.5"
11"
Hinge
Center
Note: Refer to the instruction
manual for different installation
setups. Dimensions will vary.
Front
W4
OFF
ON
Front
Front
Front Front
Top View of Type 1 Top View of Type 2
Mounting Holes Mounting HolesMounting Holes
Mounting HolesMounting Holes
Conduit Holes Conduit Holes
Mounting Holes
22”
19 1/
4”
15 3/
4”
22 1/
4”
16 1/
2”
16 1/
2”
W4
OFF
ON
CSW200UL™ Series Mounting Plate
3“ Posts mounted on Outside 3“ Posts mounted on Inside
Type 1 Type 2
Cement posts in place. Depth
of posts determined by soil
conditions and local codes.
Power and control
wiring should be run
in separate conduits.
Power and control
wiring should be run
in separate conduits.
Cement posts in place. Depth
of posts determined by soil
conditions and local codes.
3“ O.D. Heavy Walled Posts and U-Bolts
Not Provided
Distance between
posts are
critical!
Plate
MUST
be
Level!
Plate
MUST
be
Level!
Top View o
f
T
y
pe 3
F
ront
M
ounting Holes
M
ountin
g
Holes
Center
posts
between
mounting holes.
keep the posts
close to the
plate edge.
Front
Front
Front
3“ Posts mounted on Outside
SL3000UL™ Series Mounting Plate
3“ Posts mounted on Inside
Cement posts in place. Depth
of posts determined by soil
conditions and local codes.
Cement posts in place. Depth
of posts determined by soil
conditions and local codes.
Power and control
wiring should be run
in separate conduits.
Power and control
wiring should be run
in separate conduits.
3“ O.D. Heavy Walled Posts and U-Bolts
Not Provided
Top View of Type 1
Top View of Type 2
01-51150
Mounting Holes
Mounting Holes
Conduit Holes Conduit Holes
Mounting Holes
Mounting Holes
22”
19 1/
4”
13 3/
4”
13 3/
4”
18 1/
2”
Distance between
posts are
critical!
Front
25”
Type 1 Type 2
Plate
MUST
be
Level!
Plate
MUST
be
Level!
4“ Square Posts welded on Inside
4“ O.D. Heavy Walled Square Posts
Not Provided
22”
2” 19 1/
4”
Side View of Type 3
Weld
Completely
around posts.
Center
posts
between
mounting holes.
© 2004 The Chamberlain Group, Inc.
All Rights Reserved
®
™
Front
Conduit Holes
Front
4“
Minimum
Gate
Front
Type 3
Top View of Type 3
UL Rollers
Top View of Typical
Installation
For Technical Support
and Ordering Parts:
1-800-528-2806
Model # MPEL
Mounting Holes
Mounting Holes
keep the posts
close to the
plate edge.