Chargery BS12 V2.3 User manual

Operating Instructions
CHARGERY BS12 V2.3
Microprocessor controlled high performance Monitor / Reader/ Saver / Watcher for
2S~12S LiPo & LiFe battery packs.
Chargery Power Co., Ltd.
Head Office
Add: Room 6-303, Lang Qin Yu Garden, Houhai Avenue, NanShan, ShenZhen, China
Zip code: 518054
Tel: +86 755 2643 6165
Fax: +86 755 2641 2865
Email: admin@chargery.com.cn
Web: www.chargery.com

2S-12S LiPo & LiFe battery Monitor and Saver BS12 V2.3
www.chargery.com page 2 total 6
Chargery Battery Saver BS12 is the first up to 12S LiPo & LiFe battery saver with TFT color LCD applied
to helicopter; High light red LED and two loud beepers (100Db min.) make sure your flight safety.
The warning voltage, delay time and warning time can be setup by pressing easily the button.
Large TFT colorful LCD can display each cell voltage and total voltage. During battery discharge, it
can sound and LED flash alternately while any cell voltage under setup value, prevent any cell from
over discharged. Even you can check the lowest cell voltage after your helicopter land off, so you can
find the worst cell---the lowest voltage cell.
V2.1 Update note
Add a telemeter port to connect to the receiver, when any warning events happen, the transmitter can
sense the warning events.
When start warning the telemeter port will output 5V, if no warning, it will be 0V.
V2.2 update note
Add a jump port to connect the socket 1 and socket 2, it is for two packs without any connection. If
two packs connected in series or parallel by discharge cable, the jump port must be open.
V2.3 update note
Loudly Beeper, 100dB min. at 12V
TELEMETER port renamed as BPG (Battery Pack Good)
New features
From BS12 V2.0, two packs can be connected in series or in parallel, the device can identify the
connection automatically and monitor each cell voltage accurately.
Over charge voltage can be programmed from 3.00~4.30V
Over discharge voltage can be programmed from 2.00~4.00V
Wait time can be programmed from 0.0~20S
Alarm time can be programmed from 1.0~60s
LCD Back-light time can be programmed from 1min, 5min, 10min, 20min and always on.
BS12 can record the lowest voltage of each cell including total pack voltage during flight, after
your helicopter land off, you can press UP/DOWN to display these voltage (cell number
background color change, and cell voltage displayed in RED text), press the button again
display real voltage.
Beeper sound and LED flash alarm while any cell over charged or over discharged.
At any time, you can press SET button shortly turn off the display and press again resume.
While alarming, press SET button shortly turn off alarm at any time.
Telemeter
Socket 1
Socket 2
UP/DOWN
C
ell
1
A
-
Cell 1A+
Cell 2A+
Cell 3A+
Cell 4A+
Cell 5A+
C
ell
6
A
+
C
ell
1B
-
Cell 1B+
Cell 2B+
Cell 3B+
Cell 4B+
Cell 5B+
C
ell 6B+
LED
SET
Beeper

2S-12S LiPo & LiFe battery Monitor and Saver BS12 V2.3
www.chargery.com page 3 total 6
Operating guideline
1. Connect the battery to BS12, keep the polarity correct. The detailed connection diagram is as the
following figure 1, figure 2 and figure 3.
2. The Device will initialize the beeper and LED, beeper sounds once time, warning LED flash once
time.
3. 2 seconds later, the BS12 will display the cell count, total voltage on the top line, and warning
voltage, delay time, warning time on the bottom line from left to right. The middle area, each cell
voltage is displayed. When any cell voltage reaches the dynamic lowest value, it is displayed in
RED color, the lowest voltage will be updated with the value changes.
4. At any time, you can press SET button shortly turn off the display and press again resume. If the
back-light time is always on, it is invalid.
5. While alarming, press SET button shortly turn off alarm at any time.
In flight, BS12 can alarm loudly and a large WARNING RED LED flash when any cell voltage under
setup value till the cell voltage over warning voltage.
If the cell voltage is still under warning voltage, the unit will beep and flash repeat for the warning
time.
The unit includes reverse polarity detection, and 2.54mm pin distance balance connector for all kinds
of battery.
Connection Diagram
1. One 2S-6S battery can plug into the socket1 directly, 3S connections as following.
Figure 1
SET
UP/DOWN
Socket 2
cell 1
cell 2
cell 3
Socket 1
LED
BEEPER
BEEPER
6+
1
-
12
+
7
-
BPG
+
-
+
-
+
-
-
+
jump
Socket 1
Socket 2
Cell count
Pack voltage
Cell count
Pack voltage
Socket 1
Socket 2

2S-12S LiPo & LiFe battery Monitor and Saver BS12 V2.3
www.chargery.com page 4 total 6
2. For two battery packs connected in series as following, plug battery 1# into socket 1, and battery
2# into socket 2 separately. Take two 3s battery sample as following:
Figure 2
3. For two battery packs connected in parallel as following, plug battery 1# into socket 1, and
battery 2# into socket 2 separately. Take two 3s battery sample as following:
Figure 3
4. For two separate battery packs without any connection, plug battery 1# into socket 1, battery 2#
into socket 2 separately, and short circuit the jump port by the jumper. Take two 3s battery
sample as following:
Figure 4
jump
Battery 1#
Socket 2
SET
UP/DOWN
LED
BEEPER
BEEPER
cell 1
cell 2
cell 3
Socket 1
6+
1
-
cell 1
cell 2
cell 3
Battery 2#
12
+
7
-
+
-
+
-
+
-
BPG
-
+
jumper
6+
1-
12+
7-
Socket 2
SET
UP/DOWN
cell 1
cell 2
cell 3
Socket 1
LED
BEEPER
BEEPER
cell 1
cell 2
cell 3
Battery 1#
Battery 2#
+
-
+
-
+
-
BPG
-
+
jump
Socket 2
SET
UP/DOWN
cell 1
cell 2
cell 3
Socket 1
LED
BEEPER
BEEPER
cell 1
cell 2
cell 3
Battery 1#
Battery 2#
6+
1
-
12
+
7
-
+
-
+
-
+
-
BPG
-
+

2S-12S LiPo & LiFe battery Monitor and Saver BS12 V2.3
www.chargery.com page 5 total 6
When two packs is connected in series or parallel or short circuit the jump port, you can connect any
combo battery pack to socket 1 and socket 2 on condition that the total cell count less than 12, such
as 6S+6S, 2S+6S, 5S+6S, 6S+3S, 6S+5S and so on.
Specifications:
Battery range: 2S-12S LiPo & LiFe battery pack
Over charge warning cell voltage: 3.00~4.30V step 0.05V, default 4.25V
Over discharge warning cell voltage: 2.00~4.00V step 0.05V, default 3.30V
Wait time when start to warn: 0.0S~20S, step 0.5 second, default 0.5S
Alarm time range:1S~60S, step 1 second, default 2S
LCD Back-light time range:1min, 5min, 10min, 20min and always on, default 5min
Accurate scope of the warning voltage: -20mV/+20mV
Cell voltage display range:0.50V~4.99V, NO display when under 0.50V
Pins distance: 2.54mm
Size:62*44.5*6 ( L*W*T, mm)
Weight: 30g
Warning LED: 11000mCd, @ 2.0V, 20mA
Two Warning beepers: 100db @ 12V and 10cm
Package: transparent heat shrink tube
Program setup
Before flight, you can enter into Program setup menu, and set up the parameter according to your
need such as over charge voltage, LCD back-light time etc.
1. Connect 2S (LiPo 7.4V, LiFe 6.4V) or under 6S
battery to the socket 1.
2. Press SET button for 3 seconds enter into
Program Setup menu.
3. Press UP/DOWN button select the item, press
SET shortly make the value flash, and press UP
/ DOWN change the value. Press SET button
shortly confirm the change. After finish all
setup, press SET for 3 seconds save change
and quit the setup menu.
4. Over charge warning voltage range is 3.00~4.30V per cell, step 0.05V, default 4.25V. During
charge, when any cell voltage over the value, the unit will alarm.
5. Over discharge warning voltage range is 2.00~4.00V step 0.05V, default 3.00V. During flight,
when any cell voltage under the value, the unit will alarm.
6. Delay time when start to warn range is 0.0S~20S, step 0.5 second, default 2.0S. Delay time
means the waiting time from cell voltage reach set up value to start alarming.
7. Warning time range is 1S~60S, step 1 second, default 2S.
8. LCD back-light time range is 1, 5, 10, 20min and always ON, default 5min. when LCD
back-light “ON” time reach setup value, it will turn off, and press any button to resume. If the
back-light time is always on, it is invalid.
9. When quit setup mode, the device will remember all parameters till next change.

2S-12S LiPo & LiFe battery Monitor and Saver BS12 V2.3
www.chargery.com page 6 total 6
Warranty and Service
Chargery Power Co., Ltd. as manufacture of R/C model power warrants its charger and saver, monitor
etc. to be free of defects in material and workmanship. This warranty is effective for 12 months from
date of purchase. If within the warranty period the customer is not satisfied with the products
performance resulting from a manufacturing defect, the accessory will be replaced or repaired.
Your selling dealer is your first point of contact for warranty issues. Return postage costs are the
responsibility of the user in all cases. Please submit copy of original receipt with the return.
Damage due to physical shock (dropping on the floor, etc.), inappropriate power supply (unstable
output voltage and insufficient power, etc.), water, moisture, and humidity are specifically NOT
covered by warranty.
Chargery Power Co., LTD.
Chuangye Road, Nanshan Shenzhen, 518054, China.
Tel: 86 (0)755 26436165, fax: 86 (0) 755 26412865
Email: jasonw[email protected]
Homepage: www.chargery.com
Table of contents
Other Chargery Computer Hardware manuals
Popular Computer Hardware manuals by other brands

Utax
Utax DP 700 Service manual

NXP Semiconductors
NXP Semiconductors SABRE i.MX 6 Series Installation and setup guide

Actel
Actel IGLOO PLUS Starter Kit user guide

Audiovox
Audiovox Verizon Wireless PC CARD PC 5220 user guide

MF DIGITAL
MF DIGITAL Cougar 6600 Client Operator's guide

Acronova Technology
Acronova Technology Xymba XB-42 Operation manual