Chromlech Elidy The Led Scream User manual

User Manual
V3.1 / Software V3.0.1

Elidy
2
Issue Change First issue: 12.11.20
V2.0 Base 12.11.22
V2.1 Lightened base 12.11.23
V2.2 Base for translation 12.11.25
V3.01 Firmware V2.0_EN 13.07.12
V3.1 Emidy Strips Firmware V3 140101
Chromlech
19, avenue Gabriel Fauré
35235 THORIGNE-FOUILLARD
FRANCE
Tel: +33 2.23.20.77.67
Fax: +33 2.23.20.75.71
E-mail: [email protected]
Website: www.chromlech.com

Elidy
3
Hello,
7KDQN\RXIRUXVLQJRXUHTXLSPHQWDQGIRU\RXUFRQ¿GHQFHLQXV
We endeavour to provide you with high quality equipment which is reliable and
easy to use and strive to meet your expectations.
,IKRZHYHU\RX¿QGGHIHFWVRUPDOIXQFWLRQVZHZLOOEHYHU\KDSS\WRUHVROYH
any problems for you as quickly as possible.
This user manual relates to all products in the Elidy range.
For your safety, please read this manual carefully before using the equipment
IRUWKH¿UVWWLPH
If you have any questions or require additional information:

Elidy
4

Elidy
6
ELIDY-S V2 & ELIDY-T

Elidy
12
Safety guidelines and
precautions for use
%HIRUHXVLQJWKHHTXLSPHQWIRUWKH¿UVWWLPHHQVXUHLWKDVQRWVXIIHUHGDQ\
damage during transit. If so, DO NOT USE the equipment and contact your
CHROMLECH dealer.
In all cases, always inspect the mechanical and electrical parts of ELIDY
HTXLSPHQWEHIRUH¿WWLQJWRFKHFNWKH\DUHQRWGDPDJHG
In particular, check the lifting points, locking pins and connectors.
If there is any doubt that one of these parts may be damaged or faulty, DO NOT
USE THE PARTS CONCERNED and contact your dealer.
The manufacturer can not be held liable for damages caused by non-compliance
ZLWKVDIHW\LQVWDOODWLRQDQG¿WWLQJLQVWUXFWLRQVFRQWDLQHGLQWKLVPDQXDORUE\
DQ\PRGL¿FDWLRQVPDGHWRSURGXFWVLQWKH(/,'<UDQJH
1RQFRPSOLDQFHZLWKVDIHW\LQVWDOODWLRQDQG¿WWLQJLQVWUXFWLRQVRUDQ\
PRGL¿FDWLRQVPDGHWRSURGXFWVLQWKH(/,'<UDQJHZLOOQXOOLI\WKHZDUUDQW\
Products in CHROMLECH's ELIDY range comply with the EC standard.
For your safety and that of others, it is essential you read this manual
carefully and follow the instructions closely.
!
This equipment is reserved for professional use.
It is not intended for domestic use. This product can cause serious or
HYHQIDWDOLQMXULHVE\¿UHHOHFWURFXWLRQDQGIDOOLQJIURPKHLJKW
2QO\H[SHULHQFHGDQGTXDOL¿HGXVHUVDUHDOORZHGWRLQVWDOODQGXVHWKH
products in CHROMLECHs ELIDY range.
Do not allow inexperienced persons to handle the products.
!

Elidy
13
Electrical safety
Check that your electrical installation complies with current standards.
Always connect the product to electrical ground.
The PSX9 power unit must be connected directly to the mains
(100-240 VAC~ / 50-60 Hz).
DO NOT CONNECT TO AN ELECTRONIC OUTPUT
(dimmer, solid-state relay, etc.)
Do not connect any device other than the PSX9 power unit to the power supply
repeater socket.
Ensure the repeater power supply is not overloaded (MAX 16 A).
To ensure the PSX9 power unit operates satisfactorily, be careful not to obstruct
the ventilation grills.
The ELIDY-S, WALL and BIG products need a hybrid power cable designed by
CHROMLECH to operate. This cable is not supplied with the product and is
available as an optional extra in a wide variety of lengths. Chromlech declines
any liability if other cables are used to operate products in the ELIDY range.
RISK OF ELECTRIC SHOCKS. ALWAYS DISCONNECT EQUIPMENT
BEFORE HANDLING OR CARRYING OUT MAINTENANCE
!

Elidy
14
Installation
3URGXFWVPXVWEHLQVWDOOHGDFFRUGLQJWREHVWSUDFWLFHE\TXDOL¿HGDQGFHUWL¿HG
personnel.
Installation personnel should wear statutory safety equipment while putting up
and taking down the system.
Ensure that the public and personnel are prevented from passing underneath
the system while it is being rigged. The rigging area must be cordoned off and
inaccessible to the public.
Never leave the system unattended
during installation.
Do not allow anybody, whether stage hands, artists or members of the public, to
climb, jump or hang from products in the ELIDY range.
Do not place any object, however small, on the equipment during
rigging. It may fall while the equipment is being suspended and cause personal
injury.
NEVER attach any equipment other than CHROMLECH accessories to ELIDY
products.
CHROMLECH is not liable for rigging accessories that are not manufactured by
CHROMLECH.
The safety cable (not supplied) must have a suitable SWL for the weight
of the device you wish to secure. The safety cable, which must be attached
correctly to the device and the support frame, must be installed so that if the
main support system fails, the fall of the device will be limited as much as
possible. If a safety cable comes into play
following a fall, IT IS ESSENTIAL to replace it.
Take the same care when taking the system down as
when installing it. Pack it away carefully after use.

Elidy
15
Further information
The protection rating for products in the ELIDY range is IP 32.
PRODUCTS IN THE ELIDY RANGE MUST NOT BE USED OUTSIDE WITHOUT
PROTECTION FROM THE WEATHER.
Risk to the eyes. Products in the ELIDY range use high-power LED
(Light Emitting Diode) light sources. As such
you are strongly advised not to look directly at the light source.
Prolonged exposure can cause ocular lesions.
'HYLFHVPXVWQRWFRPHLQWRFRQWDFWZLWKDÀDPPDEOHVXUIDFH
In all cases, comply with a distance of at least 200 mm between the devices and
QHDUE\ÀDPPDEOHVXUIDFHV
All information provided in this manual is liable to change without notice. It is
your responsibility to check for updates to this manual.
Chromlech reserves the right to modify and improve any aspect
of the products in its range over time without being obliged to incorporate these
PRGL¿FDWLRQVLQWRSURGXFWVVROGSUHYLRXVO\
It is strictly prohibited to put products in the ELIDY range in a washing machine
and even less in a microwave oven.

Elidy
16
Elidy-S
Rigging system
7KH(OLG\6LVDQDUUD\¿WWHGZLWKDVZLYHOOLQJGRXEOH\RNH
The Elidy-S-yoke has 4 main functions:
1- Attach the Elidy-S by means of a standard proprietary hook
2- Attach to another Elidy-S in order to create a ladder of up to
three Elidy-S suspended one underneath the other.
Assembly is by means of two M10 bolts inserted into the
external drilled holes of the yoke. (see drawing)
A safety sling must be used between arrays
and the rigging component.
3- Install the Elidy-S on the ground
Through its double yoke, the Elidy-S may be placed on the ground
and very simply swivelled into any position.
4- Install the Elidy-S on a standard proprietary mount
Diameter of through hole for hook:
13 mm (see drawing)
The hook must be able to support the
weight of the Elidy-S, namely 3.1 Kg
A safety sling must be used between the
array and the rigging component.
3 MAX
!

Elidy
17
Elidy-S V1
Connections
The Elidy-S must only be powered from a PSX9 power unit.
We recommend the use of Chromlech cables (M-cable, S-cable).
Input connector:
7KH(OLG\6LV¿WWHGZLWKRQH;/5LQSXWFRQQHFWRU
Pinouts:
Cable characteristics:
Power supply: 2 x 2mm²
Data: Screened twisted pair 2 x 0.35mm²
,WLVSRVVLEOHWRFRQQHFW(OLG\6RQWRHDFKRIWKH36;SRZHURXWSXWVLH
(OLG\6PD[LPXPSHU36;
To this end, use the Spider Box tapoff boxes provided for this purpose.
1 Power Gnd
2 DMX -
3 DMX +
4 Power 48V
G Ground (optional)
Functional diagram
G
1 4
32
The distance
between the PSX9
and the Elidy-S
tiles is 50m
maximum
TheThe
i
- Never connect more than 3 Elidy-S per PSX9 output.
- Do not chain more than 2 Spider Boxes.
!
Popular Dj Equipment manuals by other brands

SSP
SSP PROFESSIONAL LIGHTING SMART 280 W user manual

Chauvet DJ
Chauvet DJ SHOCKER PANEL 180 Quick reference guide

Martin
Martin MAC 2000 Wash XB installation guide

LTH PRO
LTH PRO PROfessional Diffusion 200 manual

Velleman
Velleman HQ Power HQSM10011 user manual

Lightmaxx
Lightmaxx LIG0009432-000 user manual