Chuphotic LI800 User manual

The Trouble Shooting chart covers most of the difficulties that you may encounter
under normal working conditions. If the UPS fails to operate properly
Please review the following steps before calling the service center.
1. Is the UPS plugged into a correct working outlet?
2. Is the line voltage within the rating specified?
3. Is the Fuse or Breaker / Circuit Protector on back panal open?
4. UPS has used long time > 2 Year that is short backup time or fault.
Please submit the following information when you call for service.
1. Model No. & Serial No.
2. Date of problem.
3. Full desciption of problem UPS.
OPERATION AND TEST UPS
TROUBLE SHOOTING
Model : SN : Date :
Rear Panel
LI800 / LI1000 / LI1200
1. Power Switch
2. USB Charger 5V 2A
3. Battery Level (Backup Mode)
4. LED 3Digits : Volt Out, %Load, Load Level, Volt In
Specification
Model
LI800
LI1000 LI1200
Power Rate(VA/W)
800/320
1000/400
1200/480
UPS System
MCU Line Interactive UPS with Stabilizer
Input Voltage
220
Vac -34% +32% (145-290
Vac)
Input Frequecy 50/60Hz
+
10% (Auto Sensing)
Output Voltage
(AVR) 220
Vac
+
10% (198-242
Vac) : Buck
-
Boost Stabilizer
Output Voltage
(Backup)
220
Vac
+2% (215.6-224.4
Vac)
Output Frequency 50/60Hz +
0.5% (Back mode)
Output Waveform AVR Mode
: Sine Wave / Backup Mode : Modiflied Sine Wave
Battery Capacity
LiFePO4
12.8V 72wh
25.6V 144wh
Backup Time PC 50W > 60min PC 60W > 60min 2xPC 60W > 60min
Charging Time
Batt.
Cap.90% in 3-6 Hours
Protection System Over
/
Under Voltage, Over Load, Short Circuit Protection
Battery Protection, Low Battery Alarm
/
Shutdown and UPS Fauit
Transfer Time 2-6
msec
LED Display
LED 3Digit for Volt Out, %Load, Load Level, Vot In,
Battery Level
Audible Alam
Backup mode, Low battery, Overload, UPS Fault
AC Line Surge Protector
SPD-300Vac 125 Joules in 2 ms 1,000,000W in 100
µ
s
Output Plug (Universal)
Plug Backup 3 / Printer 1
Standard Certification
ISO9001/14001, TIS.1291 1-2553, 2-2553, 3-2555, CE : IEC62040
Environment 0-45°C
/
RH
0-90% Non Condensing
Dimensions
(WxHxD)mm.
90x145x285
90x145x310
Weight kg.
4.3 4.5 7.0
1. AC Input 2. Auto Reset CB 3. Outlet UPS
4. Surge Laser Printer
Line Interactive UPS with Stabilizer
V2.0
LED Display and Switch
220 IN
OUT
%
U
4
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
Test UPS on battery back-up, switch off utility supply and observe ‘backup indicator’
lights. Also your PC should continue to function normally.
1. MCU Line Interactive UPS with Stabilizer
This UPS design for Computer with AVR for Under/Over Voltage (Line Interactive)
Backup Mode has Uninterrupable Supply to Critecle load for Backout or Poor
Power Quality by Battery. Then UPS autorun Normal Mode when AC Recovery.
2. Self-testing while Turn ON
Before turning on the UPS, the red / yellow / green led will be bright by
Turn On. then the UPS will be ready for operation.
3. Overload Protection
When UPS is overload while operating, which is not solved by the user in time,
it will cut off the output automatically after short time.
4. Autorun DC Start & AC Start
UPS Normal use AC Start when Backout Power.
UPS Urgent use DC Start need Run Backup mode.
UPS discharges still battery run out and cut off, UPS autorun when AC Recover.
5. Low Battery Shutdown
When the battery is about to be exhausted, UPS will shut down automatically to
protect battery’s life.
6. Turn Off UPS
1. AC Normal UPS will cut off the output and goes to AC standby mode by
pressing the switch.
2. Backup Press the switch, the UPS will be turned off after a long beep.
4
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
TROUBLE SHOOTING CHART
Battery Level / Normal
bright with a beep every
8 seconds
UPS can not be turned
ON
UPS is not connecting
to AC and overloaded
Please connect to AC
and reduce the load
Please check the AC
Input Voltage
Please send to the
agency to Repair
Replace the Fuse or Reset
Breaker, Remove some
load and check if the load
is short-circuit or fault
The input Fuse is burn
or Breaker is off
UPS suddenly turns to
Battery mode in spite of
utility line present
Save the data promptly
and Shut down the
operating system
Backup time less than
1 minute (Low Battery)
Close load and recharge
immediately
Battery problem
Replace the new battery
Recharge the battery for
at least 12 hours and
retest the backup time
Use UPS > 2 year
Replace the new battery
Charging unit fault
Please send to the
agency to Repair
Use more load over
Battery is not fully
charged
AC Input voltage is
too low
The UPS is Failure
Battery Level / Low
bright with a beep every
1 seconds
Back-up time less than
specified

CHU-EN.UPS-68.MNL.Lithium V2.0.Rev1.00/2022
WARNING : Please Charge Battery of UPS 12 Hours
Battery Need Recharging if has not used for Long Period of Time, Battery
will Start Self - Discharging which may Result in a short Service Life or the
Battery may even Cause Damage Battery Incase Out of Warranty Period
Period Battery & UPS. Be careful Location around UPS in Environment in
High Temperature, Heat, Fire and Dust, That Result in Reduced Service
Life of Battery
-
UPS.
Please followed this Caution Warning Instructions to
Achieve Maximum Service Life.
Line Interactive UPS with Stabilizer
CONNECT EQUIPMENT TO UPS
PLACE LOCATION THE UPS
Inspect items inside box:
User’s Manual & Warranty Card
UPS & Packaging Material
Mains Power Cord
Program & Communication(Option)
Examine the packing carton for damage. Notify your dealer immediately if damage
is observed. Store the packing in a safe place for possible future trans-shipment of
the UPS.
Place location the UPS on a sturdy, dry surface in a wellventilated area away from
direct sources of heat. Leave at least 100mm clearance all around the UPS to provide
adequate ventilation.
CONNECT UPS TO POWER LINE
Connect the Power Cord, to a verified Grounded 3-wire Receptacle. Do not power the
UPS using a Surge Suppressor or Power Strip. The utility power Turn ON.
UPS INDICATORS AND CONTROLS
Product contains Voltages and Battery, which are Potentially
Hazardous.
Qualified Service Personnel should perform all Repairs.
Do not try to Open the cover and to service the
system yourself,
No user serviceable parts inside.
Refer servicing to qualified Service Personnel only and warranty Condition
Product has its own internal energy source
(Battery).
Outlet receptacles may be Risk Electrical even
when the product is
not connected to an AC supply.
In case of Fire Risk, Please change the Fuse & Reset Breaker with
the same Kind and same Rate.
Product is intended for indoor use IP20 only.
Kindly note to avoid excessive Heat, Dust, Humidity
CAUTION AND WARNING
i
Enable the UPS by turning on the Power ON/OFF switch, which is situated on the
front panel.
The UPS is now ready to use. Switch on your equipment and you are ready to function.
BATTERY MAINTENANCE / BATTERY CHARGING
ON / OFF SWITCH
Turn ON this button to supply power
to the
UPS outlets. To switch off power
to the UPS
outlets
Turn OFF the switch. This switch is
situated
on the front panel of the UPS.
BACKUP INDICATOR
(Battery Level Bright & Beep )
The buzzer beeps every 8 seconds.
The battery is powering the UPS outlets.
The expected runtime for a typical personal
computer (PC) is about 10 to 40 minutes.
LOW BATTERY INDICATION
(Battery Level Low Bright & Quick Beep)
The buzzer beeps fast whenever the
battery is near the end of its runtime.
Promptly save your data and exit all
applications and shutdown the operating
system.
AC NORMAL INDICATOR
(3Digit of Volt Out, No Beep)
The UPS is supplying conditioned
utility power to its outlets.
UPS
BATTERY
OVERLOAD
PROTECTION
AUTOMATIC
VOLTAGE
REGULATION
AC SURGE
PROTECTION
Buck / Boost
FEATUREFEATURE
Connect the Power Cord, to a verified grounded 3-wire receptacle. Do not power
the UPS using a surge suppressor or power strip. The utility power Turn ON.
(UPS Plug 3 Outlet, No Backup for Printer 1 Outlet)
i
Pb
CAUTION :
BEFORE INSTALLATION & OPERATION
Do not connect a surge suppressor,
power strip, or extension cord to the
UPS outlet.
100 ÁÁ.
100 ÁÁ. 100 ÁÁ.
IP20
• Avoid direct sunlight.
•
Avoid excessive humidity or liquids.
•Avoid excessive heat.
• Avoid excessive dust.
• IP20 Indoor Use
The UPS is intended for indoor use only. Although your UPS is very rugged, its
internal components are not sealed from the environment. Kindly note the following.
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
Laser Printer
V2.0
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
OVERLOAD INDICATION
The Yellow LED flashes, with continuous
beeping. UPS protects itself at this time.
Please move some load.
Connect a Laser Printer or any
non-computer peripherals to UPS
outlets.