Cklite LED PAR 64 User manual

HIGH POWER LED PAR 64
Item No: CK-809
USER MANUAL
www.cklight.com.cn
©Copyri
g
ht

CAUTION!
Keep this device away from rain and moisture!
Unplug the mains cable before opening the casing.!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOUR INITIAL START-UP!
SAFETY INSTRUCTIONS
Every person involved with the installation, operation and maintenance of this
equipment must:
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the internet
CAUTION! TAKE CARE USING THIS PRODUCT
With high voltage you can suffer a dangerous
Electric shock when touching wires!
This equipment has left our premises in absolutely perfect condition. In order to maintain this
condition and to ensure a safe operation, it is absolutely necessary for the user to follow the
safety instructions and warning notes written in this user manual.
Important: Damages caused by the disregard of this user manual are not subject to warranty.
The dealer will not accept liability for any resulting defects or problems.
If the device has been exposed to drastic temperature fluctuation (eg: after transportation), do not switch
It on immediately. The arising condensation may damage your equipment. Leave the equipment switched
Off until it has reached room temperature.
Please make sure that there are no obvious transport damages. Should you notice any damage to the
Power connection cable or on the casing, do not connect the equipment and immediately consult your
local dealer.

This equipment falls under protection-class 1. The power plug must only be plugged into a protection
class 1 outlet. The voltage and frequency must be exactly the same as stated on the equipment.
Incorrect voltages or power outlets can lead serious damage and electrical shock.
Always plug in the power plug last. The power plug must always be inserted without force. Make sure
that the plug is tightly connected with the outlet.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections
with the mains with particular caution! Never touch them with wet hands, as this could lead to
electric shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate
next to sources of heat or cold. Disregard of this information can lead to power cord damage, fire or
electric shock.
The cable insert or the female part in the equipment must never be strained. There must always be
sufficient cable to the equipment, otherwise, the cable may be damaged which may lead to electric shock.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the equipment and
the power-cord periodically.
If extension cables are used, make sure that the core diameter is sufficient for the required power
consumption of the equipment. All warnings concerning the power cables are also valid for possible
extension cables.
Always disconnect from the mains, when the equipment is not in use or before cleaning it. Only handle
the power-cable by the plug. Never pull out the plug by tugging the power-cable, otherwise, the cable or
plug can be damaged leading to an electric shock. If the power plug or the power switch is not accessible,
the equipment must be disconnected via the mains.
If the power plug or the equipment is dusty, the device must be taken out of operation, disconnected and
then be cleaned with a dry cloth. Dust can reduce the insulation which may lead to an electric shock.
More
severe dirt in and on the equipment should only be removed by a specialist.
There must never be any liquid allowed to enter the power outlets, extension cables or any holes in the
housing of the equipment. In the event of any liquid entering the equipment, it must be disconnected
immediately. This is also valid if the equipment was exposed to high humidity. Also if the equipment is
still working, the equipment must be checked by a specialist.
There must never be any objects allowed to enter the equipment. This is especially valid for metal parts.
If any metal parts like staples or coarse metal chips are allowed to enter the equipment, the equipment
must be taken out of operation and disconnected immediately. Malfunction or short circuits caused by
metal parts may cause injuries.
Keep away from children and amateurs!
Never leave the device running unattended.

Introduction
Features
• 6-channel DMX-512
• Blackout/Dimmer/Strobe
• Individual control of Red, Green and Blue leds
• Digital Display
• Ultra bright LED’s,low power consumption
• RGB colour mixing
• Built-in colour change programs
• Up to 100,000-hour LED life span
• Beam angle 25 º
• Signal connector XLR 3-pole Male/ Female
• Indoor use only
• Sound Control
• 18x 3in1 3W LEDs (18 Red, 18 Green, 18 Blue)
• 1, 2, 3 or 6 DMX channel Mode
Overview
Installation
Remove all packing materials from the LED Par 64. Check that all foam and plastic
padding is removed.
Connect all cables.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the
product specification voltage.
Damages caused by non-observance are not subject to warranty.

Function Mode
Mode Descriptions
1 DMX Control Mode
2 RGB Manual Dimmer Mode
3 Sound Control Mode
4 Built-in Program Mode
5 Master/Slave Mode
Warning!
Verify that the power requirement printed on your unit matches the line voltage applied.
All fixtures must be connected to circuits with a suitable Earth Ground.
FUNCTIONS:
There are 2 options for using the LED Par 64: Stand-alone
DMX Mode
Stand-alone
In Stand-alone mode, you can use the menu button on the back of the device to scroll through
the options.

DMX Mode
DMX Mode Choose
When the display show “ ” Push ENTER button into sub-
menu . Push Enter button again enter into Mode Choose Menu.
Choose from 1 to 4 mode. As following:
,Mode 1 Mode 3
Mode 2 Mode 4
DMX Address Adjust:
DMX Address choose
Choose any DMX Address from to
The LED Par 64 will automatically detect the presence of a DMX signal.If a DMX signal
is present, the DMX LED will blink.
In order to receive a DMX signal, the controller must be attached to a DMX controller by
a 3-pin DMX cable and the DMX controller must be turned on.
The LED Par 64 system can operate as a 1, 2, 3 or 6-channel DMX fixture.
Connect Method:
DMX Mode 1: Channel 1 Macro colors
DMX Mode 2: Channel 1 Macro colors
Channel 2 Dimmer
DMX Mode 3: Channel 1 Red
Channel 2 Green
Channel 3 Blue
DMX Mode 4: Channel 1 Dimmer
Channel 2 Red
Channel 3 Green
Channel 4 Blue
Channel 5 Macro colors
Channel 6 Strobe

RGBS MODE
0-255 Red from 0 – 100%
0-255 Green from 0 – 100%
0-255 Blue from 0 – 100%
0-255 Strobe, from slow to fast
Red
Green
Blue
Strobe
Sound Control Mode:
Sound Control Mode
Under this mode, the Light will change color according to external sound rhyme.
Built-in Program Mode:
1,P0~P8 8 built-in program
2,Speed Speed from 1~100
Bult-in Program Mode
Bult-in program choose
Speed Adjust
Master/Slave Mode:
The Master/Slave mode will allow you to link up to as many units you want in a daisy chain
fashion. In this mode, the first unit in the daisy chain will automatically command all other units.
Master/slave Mode
It can be set Master in this three Mode: RGBS, SOUND, Build in program, only one
Master.
Maintenance
1. All screws used for installing the device or parts of the device have to be tightly
connected and must not be corroded.
2. There may not be any deformations on housings, fixations and installation spots.
3. Mechanically moving parts like axles, eyes and others may not show any traces of
wearing.
4. The electric power supply cables must not show any damages or material fatigue.
The LED Par 64 requires almost no maintenance. However, you should keep the unit
clean. Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the
mains power supply, and then wipe the cover with a damp cloth. Do not immerse in
liquid. Wipe lens clean with glass cleaner and a soft cloth.

Do not use alcohol or solvents.
Keep connections clean.
Disconnect electric power, and then wipe the DMX and audio connections with a
Damp cloth. Make sure connections are thoroughly dry before linking equipment or
supplying electric power.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found.
Once the unit operates properly, do not carry out following steps.
1. If the device does not operate properly, unplug the device.
2. Check the power from the wall, all cables etc.
3. If all of the above appears to be O.K., plug the unit in again.
4. If you are unable to determine the cause of the problem, do not open the LED Par 64,
as this may damage the unit and the warranty will become void.
No Light
This troubleshooting guide is meant to help solve simple problems. If a problem occurs,
carry out the steps
Below in sequence until a solution is found. Once the unit operates properly, do not
carry out following steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect two potential problem areas: the power supply or the LEDs.
1. Power supply. Check that the unit is plugged into an appropriate power supply.
The LED-64 is a DMX-512 controllable, full RGB colour mixing Par Can made up of high
efficiency and super bright LED’s. There are three colour groups (red, blue and green) whose
intensity can be controlled individually allowing the creation of an unlimited range of colours.
The LED-64 will operate in stand-alone, Master/Slave and via DMX-512 control
Utilizing 6 channels.
Technical Specifications
Size: L300*W300*H295mm
Unit Weight: 4 K.G
Gross Weight: 5 K.G
Body Temperature: <45 degree
AC input: 240V/50~60Hz
Data Input: Locking 3-pin XLR male socket
Data output: Locking 3-pin XLR female socket
DMX Channels: 6
Table of contents
Popular Floodlight manuals by other brands

Chauvet Professional
Chauvet Professional Ovation Min-E-10CW Quick reference guide

Chauvet
Chauvet Colordash Par-Tri Quick reference guide

Francis Searchlights
Francis Searchlights FH560 User instruction & installation manual

Sealey
Sealey LED112.V2 instructions

Ritos
Ritos A1D08B1 manual

Probrite
Probrite FSXD30-PC-4K-BZ INSTALLATION, USAGE, & CARE GUIDE

Eterna
Eterna VECOF10PIR installation instructions

g-lites
g-lites Shooting Star Operation manual

Cooper Crouse-Hinds
Cooper Crouse-Hinds Paulihn hazFlood DFL Series Installation & maintenance information

Larson Electronics
Larson Electronics EPL-LED-150W-RT-JB2-X24V-75C-24W07 instruction manual

Chauvet
Chauvet COLORado Batten 72 Tour Quick reference guide

ADJ
ADJ 5P HEX User instructions