GigaTera MAHA-PLUS Series User manual

MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Safety Precautions (1/2)
01. Electrical work must be performed by a qualified and licensed electrician.
02. Be sure to perform the construction and grounding work in accordance with the
technical standards and instruction manual.
03. Make sure to ground the product and mounting platform properly. Incomplete grounding
may cause product damage, electric shock or fire.
04. In order to prevent the danger of electric shock, cut off the main power and confirm that there is
no leakage current before installing.
05. Make sure to turn off the power so there is no leakage current when binding the LED fixture.
There is a possibility of LED chip damage due to no-load voltage.
06. Do not install damaged product! This luminaire has been properly packed so that no parts should have been
damaged during transit . Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
~
Copyright © 2022 GigaTera Lighting Inc. All rights reserved. / www.gigateraled.com
Document Revision_220524_EU

MAHA-PLUS Series
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
/
()
/
/
Document Revision_220524_EU

< MAH1K0 >
�Size : 620 x 543 x 275 (mm) / 24.4 x 21.4 x 10.8 (inch)
�Weight : 15.2 kg / 33.5 lb
< BKT : KMDLMBK010320 >
MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Document Revision_220524_EU
Product Dimension
620mm(24.4")
543mm(21.4")
275mm(10.8")
Ø12mm(0.5") 3-Ø22mm(0.9")
150mm(5.9")
80mm(3.1")
Cable Guide
CONNECTOR SECTION MAX
M16
M25
Ø min
(mm)
Ø max
(mm) TORQUE MAX VOLTAGE SUPPORTED
DALI Cable
AC 3 Core
M20
DC 3 Core
Ø4.5
Ø9
Ø7
Ø10
Ø17
Ø13
10 Nm
12 Nm
12 Nm
1000 V
1000 V
1000 V
2.5 mm2
2.5 mm2
2.5 mm2
MAHA-PLUS 1K0

MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Document Revision_220524_EU
Product Dimension BLU1K2 & BLU 1K0
DC Power Cable
Size : 20.3” x 6.4” x 7.1” / 516mm x 161.5mm x 179.95mm
Weight : 22.1 lb / 10 kg
IP Rate : IP66
6.4"(161.5mm)
1.3"(32.1mm)
15.6"(396.0mm)
"(161.5mm)
"(25.0mm)
20.3"(516.0mm)
n0.4"(10.0mm)
3.3"(85.0mm)
0.6"(15.0mm)
16.7"(423.0mm)

STEP 01 : Attach the MAHA-PLUS to the pole. STEP 02 : Bolts not included with product
M20, 3ea or 1ea
180°
MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Installation Instruction (1/4)
Document Revision_220524_EU
STEP 03 : Fix the bracket bolt. (4 EA)
Angle
Meter 17mm 30Nm x 4
Reverse Type

STEP 04 :
MAHA-PLUS must be installed
that the glass surface of the
product is horizontal
‘0’ degree to the ground.
[ X ]
[ O ]
DC Cable
MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Installation Instruction (2/4)
Document Revision_220524_EU
0°
Ground
over
0°
0°
Ground
X
O
STEP 05 : Please match the cable colors as
shown.
Conductor termination
Open the clamping unit using the lever and insert
conductor. Then, lower the lever to close the clamp.
Important : Make sure they are clamped tightly.
DC+
DC-

STEP 06 : Close the junction box and make
sure sealing of cover and DC cable gland to
protect from water & dust
STEP 07 : When wiring, make sure that the
DC cable is sucient.
MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Installation Instruction (3/4)
Document Revision_220524_EU
X
O
STEP 08 : Fix the driver with bolts STEP 09 : Open the case cover and Insert the
Dali cable
n0.4"(10.0mm)
3.3"(85.0mm)
0.6"(15.0mm)
16.7"(423.0mm)
Dali cable

BLU Series Installation Guide
External Remote Driver
Model : BLU1K0 / BLU1K2
Installation Instruction
Document Revision_220524_EU
DALI Control (Optional)
- All cables are not supplied by GigaTera
- In case wireless control is not required, unplug the connector
from the control board
+-
+-
* CAGE CLAMP Connection
Inserting a conductor via
Screwdriver.
AC Cable
DC Cable
The maximum cable distance between
the product and BLU driver is
2.5SQ or 12AWG, which is 80 meters.
DALI Board
AC-N (White)
F.G (Green)
AC-L (Black)
+-
+-

MAHA-PLUS Series Installation Guide
LED Flood Lighting
Model : BLU1K0 / BLU1K2
Installation Instruction (4/4)
Document Revision_220524_EU
STEP 13 : Close the case covers and
make sure sealing of cable glands and
covers to protect from water & dust.
Dali cable
AC cable
DC cable

BLU Series
External Remote Driver
Model : BLU1K0 / BLU1K2
Document Revision_220524_EU
Each driver box in the
cabinet has to be in
vertical position
Enclosure
Installation Instruction Installation of drivers inside cabinet
The distances between driver boxes or wall have
to be higher than
< ORIENTATION > < DISTANCES >
Item
1*
2**
3**
4**
5*
Distance
Min 50mm
Min 80mm
Min 50mm
Min 80mm
Min 200mm
* not mandatory if there is an active cooling inside the cabinet.
The cooling study must be done
** Recommended distances, but the temperatures inside the cabinet
and Tc driver must be checked
Enclosure
4
3
5
2
1
[AC Port at the top]
[AC Port at the bottom]

BLU Series
External Remote Driver
Model : BLU1K0 / BLU1K2
Document Revision_220524_EU
MAXIMUM Relative Humidity:
95% -> Storage & Transport
90% -> Operating (no condensation allowed)
A thermal study must be done in order to respect
A temperature sensor must be installed inside the
cabinet between two driver boxes.
The temperature measured by the sensor has
to be lower than 45°C.
A cabinet shall not be directly exposed to
the sunlight.
An active cooling can be added in the cabinet to
guarantee a maximum temperature of
45°C all along the year
< TEMPERATURES >
Installation Instruction Installation of drivers inside the mast
Enclosure

BLU Series
External Remote Driver
Model : BLU1K0 / BLU1K2
Document Revision_220524_EU
* minimum width of the door: 180mm
* minimum height of the door: 550mm
* Depending of the driver xation in the mast,
please select the most suitable hook.
Installation Instruction Installation of drivers inside the mast

BLU Series
External Remote Driver
Model : BLU1K0 / BLU1K2
Document Revision_220524_EU
Installation Instruction
Maximum number of luminaires to be connected to standard circuit breakers (fuse)
Mains voltage Max Nr luminaires connected
MCB 16A Atype
MCB 16A Btype
MCB 32A Atype
MCB 32A Btype
220V-240V 1
1
3
3
220V-240V
220V-240V
220V-240V

MAHA-PLUS Series
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Document Revision_220524_EU
This manual suits for next models
1
Table of contents
Other GigaTera Floodlight manuals

GigaTera
GigaTera TM Series User manual

GigaTera
GigaTera SUFA-H User manual

GigaTera
GigaTera TM Series User manual

GigaTera
GigaTera SUFA-M Series User manual

GigaTera
GigaTera MAHA User manual

GigaTera
GigaTera WAPA Series User manual

GigaTera
GigaTera MAHA User manual

GigaTera
GigaTera SUMA User manual

GigaTera
GigaTera SUFA User manual

GigaTera
GigaTera SUFA-M User manual