EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cleveland
  6. •
  7. Heat Pump
  8. •
  9. Cleveland WS05H2 User manual

Cleveland WS05H2 User manual

This manual suits for next models

8

Other Cleveland Heat Pump manuals

Cleveland BLV-1500C6 User manual

Cleveland

Cleveland BLV-1500C6 User manual

Cleveland BLH10H2 User manual

Cleveland

Cleveland BLH10H2 User manual

Cleveland WS-0500C6 User manual

Cleveland

Cleveland WS-0500C6 User manual

Cleveland BLH10H2 User manual

Cleveland

Cleveland BLH10H2 User manual

Popular Heat Pump manuals by other brands

MICROWELL HP 1000 GREEN Installation and user manual

MICROWELL

MICROWELL HP 1000 GREEN Installation and user manual

Sanyo SAP120FCH Service manual

Sanyo

Sanyo SAP120FCH Service manual

Daikin EHYHBH05AA Operation manual

Daikin

Daikin EHYHBH05AA Operation manual

Panasonic WH-SDF03E3E5 Design handbook

Panasonic

Panasonic WH-SDF03E3E5 Design handbook

Bryant 544B Specifications

Bryant

Bryant 544B Specifications

Airxcel 45000 Series Installation, operation and maintenance instructions

Airxcel

Airxcel 45000 Series Installation, operation and maintenance instructions

Mitsubishi Electric PUZ-SWM60VAA Service manual

Mitsubishi Electric

Mitsubishi Electric PUZ-SWM60VAA Service manual

Dimplex LI 16I-TUR Installation and operating instruction

Dimplex

Dimplex LI 16I-TUR Installation and operating instruction

Carrier WSHP Open v3 Integration guide

Carrier

Carrier WSHP Open v3 Integration guide

TGM CTV14CN018A Technical manual

TGM

TGM CTV14CN018A Technical manual

Carrier 38MGQ Series installation instructions

Carrier

Carrier 38MGQ Series installation instructions

Kokido K2O K880BX/EU Owner's manual & installation guide

Kokido

Kokido K2O K880BX/EU Owner's manual & installation guide

Viessmann VITOCAL 300-G PRO Type BW 2150 Installation and service instructions

Viessmann

Viessmann VITOCAL 300-G PRO Type BW 2150 Installation and service instructions

Carrier 48EZN installation instructions

Carrier

Carrier 48EZN installation instructions

Viessmann KWT Vitocal 350-G Pro Series Installation and service instructions for contractors

Viessmann

Viessmann KWT Vitocal 350-G Pro Series Installation and service instructions for contractors

Ariston NIMBUS user manual

Ariston

Ariston NIMBUS user manual

Weishaupt WWP L 7 Installation and operating instruction

Weishaupt

Weishaupt WWP L 7 Installation and operating instruction

GE Zoneline AZ85H09EAC datasheet

GE

GE Zoneline AZ85H09EAC datasheet

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Cleveland
™
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COOK CHILL SYSTEMS Cook/Chill Systems
SECT.XIV PAGE 51
0707
WATER COOLED
CONDENSING UNITS
MODELS:
c
WS05H2
c
WS15H2
c
WS30H2
c
WS07H2
c
WS20H2
c
WS35H2*
c
WS10H2
c
WS25H2
c
WS40H2*
*These units are not supplied with
fused disconnects
Cleveland Standard Features
nWater cooled condensing unit for indoor installation
nFor operation with R-22, 404A or 507 refrigerant (please
specify)
nLiquid line filter with replaceable core and sight glass
nHigh efficiency Copeland discus compressor
nSpring isolation of compressor
nShell and tube, cleanable, water cooled condenser with pres-
sure relief valve
nWater regulating valve
nPre-wired control panel with compressor contactor and con-
trol circuit fuse
nLiquid receivers with inlet and outlet valves and pressure
relief
nSuction and discharge vibration eliminators
nCrankcase heater for cold temperature operation
nSuction filter with replaceable core
nSuction accumulator
nOil separator
nLow ambient kit
nAnti short cycle timer
nLiquid solenoid valve (shipped loose)
nDry contacts for compressor alarm
nAccepted for use in U.S.D.A. Inspected Facilities
Options & Accessories
pAir Cooled Condensing Units
pLarger models available upon request
pExtended four (4) year compressor warranty
(domestic only)
pIce Water Control Panel for location in production area
pIce Builders
Shall be CLEVELAND Model WS ____ H2, Indoor, ____ HP, WATER
COOLED CONDENSING UNIT for Ice Builder. Compressor;
Receiver with Discharge and Suction Line Vibration Eliminators;
Pressure Control; Drier/Sight Glass Kit; Liquid Line Solenoid Valve;
replaceable Core Suction Line Filter, Suction Line Accumulator; Oil
Separator and Oil Failure Safety Control; Head Pressure Control
Valve; Control Panel with hinged door
housing Low Ambient Kit, Compressor Contactor and Control
Circuit Fusing; Water Cooled Condenser is cleanable.
Short Form Specifications
SECT. XIV PAGE 52
0707
Litho in USA
Cleveland Range reserves right of design improvement or modification, as warranted.
MINIMUM CLEARANCE
FRONT 24"
SIDES 24"
REAR 24"
DIMENSIONS
SHIPPING WEIGHTS
MODEL A B C D LBS / KG
WS-05-H2 IBC-25 36" 60 7/8" - - 780 \ 355
WS-07-H2 IBC-50 52" 61 3/8" - - 780 \ 355
WS-10-H2 IBC-75 60" 58 3/8" - - 870 \ 386
WS-15-H2 IBC-100 60" 60 3/8" - - 1088 \ 495
WS-20-H2 IBC-125 - - 75" 69 5/8" 1163 \ 529
WS-25-H2 IBC-150 - - 72" 71 1/8" 1178 \ 536
WS-30-H2 IBC-175 - - 72" 70 5/8" 1200 \ 546
WS-35-H2 IBC-200 - - 72" 73 7/8" 1600 \ 728
WS-40-H2 IBC-250 - - 72" 76 7/8" 1380 \ 628
UTILITY CONNECTIONS ELECTRICAL 208 / 3PH
RECEIVER COLD COMPRESSOR UNIT
MODEL CAPACITY LIQUID SUCTION WATER RLA MOPD
WS-05-H2 72 lbs 5/8" 1 3/8" 1 1/4" 31.6 60
WS-07-H2 137 lbs 5/8" 1 3/8" 1 1/4" 31.6 60
WS-10-H2 187 lbs 7/8" 1 3/8" 1 1/4" 43.6 80
WS-15-H2 239 lbs 7/8" 1 5/8" 1 1/2" 59.6 110
WS-20-H2 336 lbs 7/8" 1 5/8" 2" 66 125
WS-25-H2 385 lbs 1 1/8" 2 1/8" 2 1/2" 82.2 150
WS-30-H2 425 lbs 1 1/8" 2 1/8" 2 1/2" 94 175
WS-35-H2 557 lbs 1 1/8" 2 1/8" 2 1/2" 107 200
WS-40-H2 602 lbs 1 1/8" 2 1/8" 3" 142 250
REFRIGERANT NOT SUPPLIED BY CLEVELAND RANGE.
AIR COOLED CONDENSING UNITS ARE FOR OUTDOOR INSTALLATION.
WATER COOLED CONDENSING UNITS ARE FOR INDOOR INSTALLATION.
RLA –RATED LOAD AMPS
MOPD – MAX OVERCIRCUIT
PROTECTION DEVICE
D
1D
2
B
ELECTRICAL
ENCLOSURE
COMPRESSOR ASS'Y.
REFRIGERANT
RECEIVER
SUCTION FILTER
LIQUID LINE
FILTER-DRIER SUCTION ACCUMULATOR OIL SEPARATOR
WATER COOLED
CONDENSER
SUCTION CONNECTION
LIQUID CONNECTION
WATER OUTLET
WATER INLET
C
D
40 9/16"
OIL SEPARATOR
LIQUID LINE
FILTER-DRIER
ELECTRICAL
ENCLOSURE
REFRIGERANT
RECEIVER
SUCTION
FILTER
WATER COOLED
CONDENSER
SUCTION
ACCUMULATOR
LIQUID CONNECTION
SUCTION CONNECTION
WATER INLET
WATER OUTLET
36 1/16"
COMPRESSOR
ASSEMBLY
B
A
FOR MODELS
:
WS-05-H2
WS-07-H2
WS-10-H2
WS-15-H2
FOR MODELS
:
WS-20-H2
WS-25-H2
WS-35-H2
WS-40-H2
(NOT TO SCALE)