Cloud CX-A200 Operation manual

CX-A200 Amplifier
Installation & User Guide
Cloud Electronics Limited
140 Staniforth Road, Sheffield, S9 3HF England
Tel +44 (0)114 244 7051
Fax +44 (0)114 242 5462
e-mail inf[email protected].uk
web site http://www.cloud.co.uk

CX-A200 INSTALLATION AND OPERATION MANUAL 1
CX-A200 Amplifier
Installation and operation manual
Contents
Section Page
1 Safety Notes...............................................................................2
2 General Description....................................................................2
3 Installation..................................................................................2
4 Input Facilities ............................................................................3
5 Output Details.............................................................................5
6 100V Line operation ...................................................................5
7 Bridged Mode Operation ............................................................5
8 Status Indicators.........................................................................5
9 VCA Modules .............................................................................5
10 Fitting VCA Module ....................................................................6
11 Remote Level Connections ........................................................6
12 Field Servicing............................................................................7
13 General Specifications................................................................7
14 Technical Specifications.............................................................7

CX-A200 INSTALLATION AND OPERATION MANUAL 2
1 Safety Notes
The CX-A200 contains several PCB mounted jumpers which can be set to provide the
desired configuration for a specific venue or installation. These adjustments should be
performed by a technically qualified person who understands the hazards associated with
mains operated equipment. Do not remove the top panel unless you are qualified to do
so.
Remove the power cable from the unit before removing the top panel and do not make
any adjustments with the unit switched on.
The CX-A200 is supplied with a power cable fitted with a moulded plug. If the plug is cut
off the lead for any reason, remember that the discarded plug is a potential hazard and
should be disposed of in a responsible manner.
2 General
The CX-A200 is a four channel power amplifier with a maximum output of 50 watts per
channel into 4 ohm loads. The unit features extremely low distortion and low noise
together with a high slew rate. Full circuit protection is provided and the load is
disconnected if the heatsink overheats or any DC is detected at the output. A five second
switch-on delay operates to avoid any switching thumps or other extraneous signals
reaching the speaker system.
All four input amplifiers are balanced and connect via 3 pin XLR type connectors with
adjacent level controls, all mounted on the rear panel. Input signal routing jumpers are
provided and allow the unit to operate in many configurations whilst retaining simple input
connections.
The CX-A200 amplifier can be used with up to two optional plug-in two channel VCA
modules to provide remote level control. Each plug-in module can operate as two
individual attenuators with two remote level controls, or can be linked to operate as a
stereo pair with one remote level control.
3Installation
The CX-A200 is suitable for mounting in a standard 19" equipment rack and occupies two
units of rack space. Sufficient ventilation must be provided for the unit. The amplifier
draws cool air through the front panel and exhausts through the back panel and care
must be taken not to obstruct the air flow otherwise the unit may intermittently turn off due
to the built-in thermal protection. The unit is 300mm deep but a depth of 375mm should
be allowed to clear the connectors.

CX-A200 INSTALLATION AND OPERATION MANUAL 3
4 Input Facilities
All four inputs are balanced and use 3 pin XLR type connectors. All inputs are wired to
the standard convention of pin 1 ground, pin 2 in-phase, pin 3 reverse phase, with the
shell of the connector connected to the chassis. If the unit is operating in a location which
has a high level of electrical or magnetic disturbance or is close to a TV or radio
transmitter, we suggest that the input cable screen be connected to the shell of a metal
XLR type connector. If the signal is from an unbalanced source, connect pin 3 to pin 1
(ground) inside the XLR type connector and use pin 2 as hot.
Each input has a level control adjacent to the respective XLR type connector. PCB
mounted jumpers provide input routing on channels 2, 3 & 4 allowing a wide variety of
input routing configurations. See the schematic diagrams showing details of various
routing possibilities.
In its default configuration, the unit operates as four independent amplifiers.
Two stereo pairs, driven from one stereo source and four channels driven from one mono
source are also possible together with a combination of the two by suitably configuring
the input routing jumpers.
1 2 3 4
1
2
1
3
2
4
INPUT 1
1234
POWER
AMPLIFIER
LEVEL
CONTROL
SOURCE
JUMPERS
INPUT
AMPLFIER
FROM MONO SOURCE
FOUR CHANNELS DRIVEN FROM ONE MONO SOURCE

CX-A200 INSTALLATION AND OPERATION MANUAL 4
1 2 3 4
1
2
1
3
2
4
1 2 34
POWER
AMPLIFIER
LEVEL
CONTROL
SOURCE
JUMPERS
INPUT
AMPLFIER
INPUT 1
FROM STEREO SOURCE
TWO STEREO PAIRS FROM ONE STEREO SOURCE
INPUT 2
1 2 3 4
1
2
1
3
2
4
1 2 34
POWER
AMPLIFIER
LEVEL
CONTROL
SOURCE
JUMPERS
INPUT
AMPLFIER
INPUT 1 INPUT 2 INPUT 3 INPUT 4
FOUR CHANNELS OPERATING AS INDEPENDENT AMPLIFIERS

CX-A200 INSTALLATION AND OPERATION MANUAL 5
5 Output Details
Binding posts are provided on the rear panel for the four speaker outputs and these can
accommodate flexible leads up to 2.50mm². The output connector is not compatible with
4mm 'Banana' plugs. Do not make any connections to the unit with the power cable
attached. It is good practice to distance the output wiring from the input wiring.
6 100V Line operation
The Cloud CXL-400 four channel 100V line module is available as an accessory to the
CX-A200. It is rated at 40 watts per channel and optimally matches the CX-A200 power
amplifier. The module is designed to fit inside the CX-A200 chassis. The CXL-400 can
be operated at full power at frequencies as low as 40Hz without the risk of saturation.
Operation at lower frequencies with high input levels may result in the transformer
saturating and the amplifiers VI limiter operating. The unit can be configured for 70V
operation by means of wire links on the PCB.
7 Bridged Mono Operation
The unit can operate in Bridged Mode using any two channels. The inputs must be wired
together by linking the input signal at the XLR connectors of the two relevant channels,
wiring the "second" input out of phase (i.e. pin 1 ground, pin 3 in-phase, pin 2 reverse
phase). The input level controls of the two channels should both to be set to the fully
clockwise position.
The output load should then be connected between the two red binding posts of the
relevant channels (no connection to the black binding posts of the relevant channels),
ensuring that the positive wire is connected to the "first" red binding post and the negative
wire is connected to the "second" binding post.
For example, it is possible to configure four channels as two bridged outputs allowing a
stereo input to be delivered to two 100 watt 8 ohm outputs.
8 Status Indicators
The front panel of the CX-A200 has an array of LED's which indicate the status of all four
channels. The lower green LED illuminates when a signal exceeding 500mW is detected,
the yellow 'peak' LED will illuminate when the amplifier output is close to clipping and the
top red LED indicates that the protection relay has disconnected the load. Please note
that it is normal for all four red LED's to illuminate for approximately five seconds when
the unit is switched on, indicating operation of the switch-on delay circuitry. The lower
green LED indicates that the power is switched on.
9 VCA Modules
A two channel VCA module is available as a plug-in option and the CX-A200 can be fitted
with two VCA modules. Each VCA module can be supplied with either one or two control
plates. The unit can operate two channels independently or wired to provide stereo
attenuation via one control plate. The remote rotary control plate is compatible with UK
domestic electrical accessories and can be mounted onto a standard British flush or
surface mounted 25mm deep back box. Two core cable with overall screen should be
used to connect the remote level control to the module mounted inside the CX-A200. The

CX-A200 INSTALLATION AND OPERATION MANUAL 6
circuitry uses the industry standard 'Thats 2150A' VCA providing very low distortion and
up to 90dB attenuation. The VCA module can be wired to provide muting by using an
auxiliary relay connected to a fire alarm control panel. See section 11 'Remote Level
Plate Connections' for wiring details.
10 Fitting a VCA Module
Remove the power cable before commencing. Remove the top panel from the CX-A200
then remove the relevant connector cover from the rear panel of the unit. Locate the 10
pin male header (CON1 for inputs 1 & 2 and CON2 for inputs 3 & 4) then remove the two
jumpers from the 10 way header (male connector). Remove the PCB fixing screw(s)
adjacent to the 10 way connector and fit the two 40mm M3 mounting spacers into the two
positions next to CON1 or CON2. Carefully position the VCA module so that the 4 pin
connector is located just through the hole in the rear panel and locate the 10 pin female
ribbon connector on the module accurately on to the header. Make sure that the module
is accurately positioned and check that the connector is mating with all 10 pins. Secure
the module with the two M3 screws provided and replace the top panel.
11 Remote Level Plate Connections
The VCA module is a two channel device providing voltage controlled level adjustment for
two independent channels or one stereo pair. The 4 pole connector can be wired to allow
two RL-1 level plates to control individual channels or one RL-1 controlling two channels
simultaneously for stereo applications. Use two core screened cable to interconnect the
remote level plates.

CX-A200 INSTALLATION AND OPERATION MANUAL 7
12 Field Servicing
The CX-A200 is ruggedly built and uses proven reliable circuitry. It requires no more than
the occasional removal of any dust that may have built up inside the unit as a result of the
forced cooling. In the unlikely event of failure, the power amplifier module (4 channels)
complete with power supply components and input circuitry can be replaced without
special tools and is available as a tested replacement assembly complete with heatsink.
Proceed as follows to replace the power module:
Disconnect all the leads and connectors from the rear of the unit.
Ensure that the mains supply lead has been disconnected.
Remove the CX-A200 from the equipment rack.
Remove the top panel.
Remove the 10 way ribbon cable and the four spade terminal which connect the
transformer. Disconnect the red and black fan supply wires.
Remove the VCA modules (if fitted) complete with the mounting spacers.
Remove the eight fixing screws from the input connectors and the two fixing screws from
the output connectors. Now remove the PCB fixing screws and carefully remove the PCB
Now fit the replacement unit by proceeding in reverse order.
No setting up is required and the unit should operate normally.
13 General Specifications
Inputs Balanced via 3 pin XLR type connectors
Outputs Binding Posts for flexible cables up to 2.5mm²
Protection VI limiting, DC offset, Thermal and Switch-on Delay
Status Indicators LED indicators on each channel for Signal, Peak &Protect
Cooling Force cooled using three speed DC fan
Dimensions 482.6mm x 88.0mm (2U) x 300.0mm deep (+ connectors)
Weight 6kg net
14 Technical Specifications
Rated output 50 watts/4 ohm load 35 watts/8 ohm load
Bridged Output 100 watts/8 ohm load
Frequency Response ±1dB 10Hz to 50kHz
THD <0.05% 20Hz/20kHz 8 1dB below rated output
VCA Module THD <0.03% 20Hz/20kHz
Input Sensitivity 0dBu (775mV)
Input Impedance 10k balanced / 5k unbalanced
Noise >90dB below rated output
Slew Rate 10V/µS (power amplifier)
Power Input 230V ±5% (115V ±5% available)
Fuse rating 230V - T3.15A 115V - T6.3A
Fuse type 20mm x 5mm class 3T 250V

CX-A200 INSTALLATION AND OPERATION MANUAL 8
This product conforms to the following European Standards
EN 50081-1: 1992
EN 50082-1: 1992
EN 60065 : 1994
SAFETY CONSIDERATIONS
CAUTION - MAINS FUSE
TO REDUCE THE RISK OF FIRE REPLACE THE MAINS FUSE ONLY WITH
THE SAME TYPE, WHICH MUST BE A CLASS 3, 240 VOLT, TIME DELAY
TYPE, RATED AT 3.15A WHERE THE MAINS INPUT VOLTAGE IS SET TO
230 Volts ± 5% AC. FOR A MAINS VOLTAGE OF 115 Volts ± 5% AC. THE
FUSE SHOULD BE RATED AT 6.3A
THE FUSE BODY SIZE IS 20mm x 5mm.
CAUTION - SERVICING
THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. REFER ALL
SERVICING TO QUALIFIED SERVICE PERSONNEL. DO NOT PERFORM ANY
SERVICING UNLESS YOU ARE QUALIFIED TO DO SO.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE
THIS EQUIPMENT TO RAIN OR MOISTURE.
10/09/99
Table of contents
Other Cloud Amplifier manuals

Cloud
Cloud CX-A850 Operation manual

Cloud
Cloud CX-A4 Operation manual

Cloud
Cloud mpa120 User manual

Cloud
Cloud CV SERIES User manual

Cloud
Cloud CXA Series User manual

Cloud
Cloud CX-A4 Operation manual

Cloud
Cloud CA Series User manual

Cloud
Cloud CX-A450 Operation manual

Cloud
Cloud 46 Series User manual

Cloud
Cloud VTX 4120 User manual

Cloud
Cloud MA40 User manual

Cloud
Cloud 36 User manual

Cloud
Cloud CX-A450 Operation manual

Cloud
Cloud CXA215K User manual

Cloud
Cloud CXV225NA User manual

Cloud
Cloud MA80E User manual

Cloud
Cloud 36-50 MULTI-ZONE User manual

Cloud
Cloud 46-80 User manual

Cloud
Cloud 24 Series User manual

Cloud
Cloud MA80FT User manual