Coates CE SERIES User manual

POOL HEATER
MODELS:
CE SERIES
12, 15 & 18kW
208V, 240V, 480V
SINGLE & THREE PHASE
CPH SERIES
24 & 30kW
208V, 240V, 480V
SINGLE & THREE PHASE
PHS SERIES
36, 45, 54 & 57kW
208V, 240V, 480V
SINGLE & THREE
WARNING
Only qualified personnel, as defined by National Electric Code Article
100, should install and maintain this equipment. Unauthorized
alteration or improper maintenance of this unit may release the
manufacturer from any warranty claims. The installation must be in
accordance with the instructions in this manual and applicable local
plumbing and electrical codes.
CAUTION
THE ELECTRICAL INSTALLATION MUST BE IN ACCORDANCE
WITH ARTICLE 680 OF THE NATIONAL ELECTRICAL CODE.
BEFORE YOU BEGIN
CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS
WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS CAN
BECOME LOOSE DURING SHIPMENT AND HANDLING.
INSTALLATION, OPERATION
AND MAINTENANCE
Publication 1/12

IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be followed, including the
following.
1) READ AND FOLLOW ALL INSTRUCTIONS.
2) To reduce the risk of injury.
A) The water in a pool or tub should never exceed 104°F (40°C). A water temperature in excess of
104°F is considered unsafe for all persons. Lower water temperatures are recommended for
extended use (exceeding 10-15 minutes) and for young children.
B) Since excessive water temperatures have a high potential for causing fetal damage during the
early months of pregnancy, pregnant or possibly pregnant women should limit pool or tub water
temperatures to 100°F (38°C).
C) Before entering a pool or tub, the user should measure the water temperature at several occupant
locations using an accurate thermometer since the tolerance of water temperature-regulating
devices may vary as much as ± 5°F (± 3°C).
D) Alcohol, drugs or medications should not be used before or during pool or tub use since their use
may lead to unconsciousness with the possibility of drowning.
E) Obese persons and persons with a medical history of heart disease, low or high blood pressure,
circulatory system problems, or diabetes should consult a physician before using a pool or tub.
F) Persons using medication should consult a physician before using a pool or tub since some
medication may induce drowsiness while other medication may affect heart rate, blood pressure,
and circulation.
3) SAVE THESE INSTRUCTIONS.
---WARNING---
DANGER OF HYPERTHERMIA
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the normal body temperature of 98.6°F. The symptoms of hyperthermia include dizziness, fainting,
drowsiness, lethargy and an increase in the internal temperature of the body. The effects of hyperthermia
include:
a) Unawareness of impending hazard;
b) Failure to perceive heat;
c) Failure to recognize the need to exit pool or tub;
d) Physical inability to exit pool or tub;
e) Fetal damage in pregnant women;
f ) Unconsciousness resulting in a danger of
drowning.
WARNING--- The use of alcohol, drugs or medications can greatly increase the risk of fatal
hyperthermia in pools and tubs.
Page 2

INTRODUCTION
This manual provides installation procedures,
operating and maintenance instructions and a parts list
for the Coates Pool Heater.
Your Coates Electric Swimming Pool Heater has been
designed and engineered to provide you with the most
progressive quality heating system possible. Its
operation is efficient and pollution-free. Models are
available for every size or make of pool.
To insure a long life of trouble-free service, your
Coates Pool Heater should be carefully installed in
accordance with the instructions given in this manual.
Failure to do so may damage the pool heater and the
pool equipment to which it is connected. Only
qualified personnel should install and maintain this
unit, and, of course, local plumbing and electrical
codes have precedence over these instructions.
1.0 DESCRIPTION
The Coates Swimming Pool Heater consists of a
heating tank with external enclosure, and the electrical
heating and control system. In order to help maintain
the heater in a satisfactory manner, a brief description
of its components and their operation is included for
the customer’s convenience.
The pressure vessel and its enclosure comprise the
main mechanical portion of the pool heater.
The pressure vessel, in conjunction with the flow
switch and heating element are the only portions of
this equipment in contact with the water.
The external enclosure is a sheet steel case totally
enclosing the pressure vessel and electrical
components. The enclosure is coated with a rust
inhibiting, powder coat finish.
The electrical system, which is the heart of this unit,
can be considered as three separate systems
engineered to provide optimum use of energy. They
are as follows:
(1) The heating elements; mounted on a four-bolt
flange. There are 2, 3 or 4 elements.
(2) The control system; consists of the pilot switch,
high limit thermostat, flow switch, temperature control,
magnetic contactors, 240V transformer (480V units only)
and sequencer (on some single phase units only).
These controls are wired into a control circuit designed
to control the temperature of the water leaving the
heater. The high-limit thermostat is designed to open
the control circuit and cut off the power in the event of
excessive temperature.
A flow switch is built-in to prevent the pool heater from
operating without water flow. The flow switch will
activate at flow rates of 20 GPM or greater.
(3) The main current-carrying components; are
the contactors and fuses. These are wired into circuits
which carry the full amperage draw of the elements.
The contactors open during a high temperature condition
to de-energize the elements.
The element fuses in these units are rated at 60 Amps
and have an interrupting capacity of 100,000 Amps rms.
These fuses provide supplemental circuit protection for
the internal wiring of the heater.
The heater has a temperature controller adjustable up to
104°F(40°C) and has one manual reset type high
temperature limit thermostat set at 118°F (48°C).
2.0 LOCATION AND PLUMBING
A. Installation: Location
Coates swimming pool heaters are quiet, do not expel
exhaust fumes, and may be conveniently located in a
shed or basement. Normal positioning of the pool
heater should be in close proximity to the pool filtration
system. Select a location conveniently close to
incoming electrical service and where excessively long
piping runs are not required.
Minimum clearance:
PHS/CPH CE
Front 36 (914)# 36 (914)#
Left 18 (457) 4 (102)
Right * 4 (102)
Top 18 (457) 20 (508)
Back 6 (153) *
* Required clearance is based on plumbing configuration used.
# Refer to NEC Table 110.26 (A)(1)
- Dimensions: Inches (mm)
- Temperature control is located on the front side.
WARNING
Only qualified personnel, as defined by National
Electric Code Article 100, should install and
maintain this equipment. Unauthorized alteration
or improper maintenance of this unit may release
the manufacturer from any warranty claims. The
installation must be in accordance with the
instructions in this manual and applicable local
plumbing and electrical codes.
Page 3

B. Installation: Plumbing
Pipe the heater as shown in Figure 2 to the inlet and
outlet openings on the right side. Connect the heater
in line between the filter discharge and pool. The
water line coming from the filter should be connected
to the heater inlet, and the discharge line to the pool
should be connected to the outlet. The pool will not
heat properly unless it is plumbed correctly. If plastic
pipe is used, it should be suitable for at least 120°F
(49 °C).
A plumbing bypass around the pool heater is not
necessary unless flow rate though the heater exceeds
80 GPM. A minimum flow rate of 20 GPM is required.
Lack of sufficient flow will not allow the flow switch to
activate the heater.
It may be necessary, in larger Olympic-sized or public
pools, to use two or more heaters to obtain sufficient
KW capacity. If so, the heaters must be placed in
parallel, so that each heater takes equal flow.
DRAINAGE: A method of draining water away from
the heater and other equipment is to be provided. The
heater should be flushed at the end of each swimming
season. During flushing or service, water may be
spilled and could cause damage to the floor or other
equipment. A drain valve is to be installed in the
INLET plumbing.
3.0 ELECTRICAL INSTALLATION
1.Check nameplate rating to insure the heater
matches your electrical supply.
2.CHECK ELECTRICAL CONNECTIONS TO ALL
COMPONENTS within the heater for tightness.
These can become loose during shipment and
handling.
3.Check components for any moisture, rust, or dust
which may have accumulated during shipping, and
clean or dry where necessary.
All pool heaters covered in this manual have integral
thermostats, transformers, contactors and sequencers
where required.
Wiring diagrams included show internal wiring and
required field connections for various models. Consult
your local electrical code for proper wire and conduit
sizes, and other local requirements.
Do not connect the pool heater to, or operate at, a
voltage other than the voltage rated on the nameplate.
Bring wires of adequate size from a fused disconnect
switch or circuit breaker with an ampere rating of
125% of the ampere rating shown on heater
nameplate. Refer to Table 1 for wire sizes. Connect
power conductors to the power distribution block inside
the heater. All other internal connections are completed
and tested at the factory.
Ground wires must be insulated copper conductor and
the same size as supply wiring, but not less than #12
AWG.
Table 1
WIRE SIZE: AWG
KW 240V/1Ø 208V/3Ø 240V/3Ø 480V/3Ø
12 4 8 8 12
15 4 6 8 10
18 3 4 6 10
24 1 3 4 8
30 2/0 2 3 8
36 3/0 1 2 8
45 250MCM 2/0 1/0 4
54 350MCM 3/0 2/0 3
57 350MCM 3/0 2/0 3
Suggested size for insulated copper conductor
wires. Based on 125% correction factor for wire
with 75°C insulation.
A. To Connect Pool Heater to Power Supply
The pool heaters with load ratings over 48 Amps have
branch supplemental fusing already installed in the
element circuitry; see wiring diagrams. To connect to
the power supply, one needs only to protect the main
supply lines, either with a circuit breaker or fused
disconnect switch (Figure 1). Suggested wire sizes are
shown in Table 1.
Figure 1
B. Startup Procedure:
1. Make sure that the pump is on and that there is at
least 20 GPM flow through the pool heater. The
heating elements will fail prematurely if allowed to
operate with insufficient water flow.
2. Check temperature control setting, also, examine
wiring for loose connections, etc.
3. Turn on power at main disconnect switch.
4. Turn on pilot switch on pool heater.
If the high temperature manual reset high limit switch
shuts off the heater, disconnect power at disconnect
switch and determine the cause before resetting.
Page 4

4.0 CONTROL PANEL
A. INDICATOR LIGHTS
The control has three indicator lights and a lighted ON-
OFF rocker switch. The lights are as follows:
STATUS LIGHTS
LIGHT DESCRIPTION (when Illuminated)
ON-OFF Heater has power to control circuit.
RESET High Temperature limit is OK.
FLOW Sufficient water flow through heater.
ELEMENT Heating elements are powered.
B. DIGITAL THERMOSTAT CONTROL
For heaters equipped with a digital thermostat. The
digital thermostat control which measures the
temperature of the water as it enters the heater has a
MENU button, up and down adjustment buttons, and
an LED display. The desired water temperature (set
point) is controllable between 40°F and 104°F (5°C
and 40°C). The set point may differ from the actual
water temperature at the pool or spa due to heat loss
in the piping.
MENU:
The MENU button cycles through the three menu
items: Measured Water Temperature (default), SET
POINT and °F/°C.
ADJUSTING THE SET POINT:
Press one of the following buttons; MENU, or .
The display will momentarily blank and then the
current set point will be displayed. Press the or
button to change the set point. Hold the button down
for rapid temperature changes.
The set point will be saved and the display will return
to the measured temperature after two seconds of
inactivity.
OPERATION:
In the measured temperature mode, the water
temperature in the heater is displayed. The LED
corresponding to the current temperature scale will be
illuminated. If the heater is calling for heat the
HEATING LED will be illuminated.
FAHRENHEIT TO CELCIUS:
Press the MENU button twice and the current
temperature scale will be displayed ( F or C ). Press the
or buttons to toggle between F and C.
The temperature scale will be saved and the display will
return to the measured temperature after two seconds of
inactivity.
ERROR CODE:
The display will read “Err” when it detects a problem with
the temperature sensor. This can be caused by a faulty
sensor or a loose connection between the sensor and
the temperature controller.
5.0 MAINTENANCE
Element Inspection and Replacement:
1. Turn off power at main disconnect switch and turn
off pump.
2. Drain pool heater.
3. Remove service access panel opposite inlet/outlet.
4. Disconnect element wires.
5. Remove the four (4) element flange retaining nuts
and extract element.
6. Installation is the reverse of steps 1 through 5.
(Reinstall element with new gasket)
When closing down the pool for any length of time, shut
off the power at the main disconnect switch and drain
the water from the system. Water must not be allowed
to freeze in the heater, as this will cause severe
damage.
Annual Cleaning:
Yearly, before winter, the pool heater should be drained
and cleaned to remove any scale or sludge. More
frequent cleaning may be required if pool water contains
sediment or any amount of foreign matter.
1. Turn off heater at main disconnect switch.
2. Open drain valve.
3. Permit water to run until it is clear.
4. Close valve and restart normally.
Page 5

TOTAL kW PER HEATER
AMPERAGE AT FULL LOAD
ELEMENTS PER HEATER
kW PER ELEMENT
FUSE, F-1, SC-60, 60A/480V
FUSE, F-5, FNQ-R-1, 1A/600V
FUSE, F-6, FNM-1/2, 0.5A/250V
T5, XFMR 480V/240V-50VA
CR-7 CONTACTOR 3P, 208/240V COIL
RS-2 ROCKER SWITCH, LIGHTED 240V
TS-1 HIGH TEMP. LIMIT
PL-1, 2 & 4, PILOT LIGHT, AMBER 120/240V
PL-3, PILOT LIGHT, AMBER 480V
ELEMENT GASKET
FLOW SWITCH
18
3
4
7
17
10
11
9
9
13
6
COMPONENTS
29018910
29016310
29015054
22012200
21001000
16 CR-8 CONTACTOR 4P, 208/240V COIL 21001300
23001521
22003820
29034620
29034648
44000250
23000105
PART No.
12412CE
12415CE
12418CE
12424CPH
12430CPH
12436PHS
12445PHS
12454PHS
12457PHS
SINGLE PHASE 240V
12 15 18 3624 30 45 54 57
32012CE
32015CE
32018CE
32024CPH
32030CPH
32036PHS
32045PHS
32054PHS
32057PHS
THREE PHASE 208V
12 15 18 3624 30 45 54 57
32412CE
32415CE
32418CE
32424CPH
32430CPH
32436PHS
32445PHS
32454PHS
32457PHS
THREE PHASE 240V
12 15 18 3624 30 45 54 57
34812CE
34815CE
34818CE
34824CPH
34830CPH
34836PHS
34845PHS
34854PHS
34857PHS
THREE PHASE 480V
12 15 18 3624 30 45 54 57
HEATER MODEL No.
ILLUSTRATION ITEM No.
51 64 77 102128153191 225238 34 5042 67 84 101126 150 158 30 37 45 59 74 89 111 130137 15 19 22 29 37 69655544
222223 22222 22222 2 222233443333344 44 44
666699991212 1212 1212 12121515151515 1515 15311112323232
66 666666 66 66612121212 12 1210 10 9 9 9 9
222222222 22222 2222 222222222 222
222222
1111 11
POOL HEATER PARTS LIST- L
1
2
3
HEATERS WITH MULTIPLE ELEMENT SIZES
2 EACH AT 12kW & 2 EACH AT 15kW
1 EACH AT 12kW & 3 EACH AT 15kW
1 EACH AT 6kW & 1 EACH AT 9kW
111111 111
11 11
44 77 882255
55
5522
55
222222222
1
333
111
22222 22 22
111111111
222 222 222 22222 22224444 444444422 4
33 333 3333 3333333 33333333333
4444
POOL HEATER PARTS LIST
MODELS CE, CPH & PHS
111
1 11111 111 1 11111 111111111111111111111
1 111 1 1 111111111111111111111111111111
222222
1 111 1 1 111111111111 1 11111 111111111111
1 111 1 1 111111111111111111111111111111
ELEMENT, 6 kW, 208V12 20006036
ELEMENT, 9 kW, 208V12 20006029
ELEMENT, 12 kW, 208V12 20006003
ELEMENT, 15 kW, 208V12 20006004
ELEMENT, 6 kW, 240V12 20006046
ELEMENT, 9 kW, 240V12 20006039
ELEMENT, 12 kW, 240V12 20006009
ELEMENT, 15 kW, 240V12 20006010
ELEMENT, 6 kW, 480V12 20006056
ELEMENT, 9 kW, 480V12 20006049
ELEMENT, 12 kW, 480V12 20006015
ELEMENT, 15 kW, 480V12 20006016
21
12
2
2
3
3
2
23
1
21
12
2
2
3
3
2
23
1
21
12
2
2
3
3
2
23
1
21
12
2
2
3
3
2
23
1
2233
A
SPECIAL INFORMATION
NOT SHOWN IN ILLUSTRATION
15 21005505
K-7 SEQUENCE TIMER 1-POLE 1 1
14 21006010
RELAY, 30AMP, SPST, NO 1 1 1 1 1 1 1 11 1 11111111 1 11111111 1 11111111
TS-3 DIGITAL POOL STAT822002150
Page 6

1
1. POWER DISTRIBUTION BLOCK
2. GROUND LUG
3. CONTROL TRANSFORMER PRIMARY FUSING
4. CONTROL TRANSFORMER SECONDARY FUSING
5. EXTERNAL CONTROL CONNECTION
6. FLOW SWITCH
7. CONTROL TRANSFORMER (WHEN REQUIRED)
8. TEMPERATURE CONTROL
9. PILOT LIGHTS – ELEMENT, FLOW, RESET
10. PILOT SWITCH, LIGHTED "ON/OFF"
11. TEMPERATURE LIMIT SWITCH
12. HEATING ELEMENT
13. HEATING ELEMENT GASKET
14. FLOW RELAY
15. SEQUENCE TIMER (WHEN REQUIRED)
16. CONTACTOR (4-POLE)
17. CONTACTOR (3-POLE)
18. HEATER CIRCUIT FUSING
19. VESSEL
20. ENCLOSURE
NOTE:
REFERENCE THE POOL HEATER PARTS LIST FOR
COMPONENT PART NUMBERS AND QUANTITIES.
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
18
19
20
DPH-ILL D
14
Page 7

Proper water balance is important to extending the life of your Coates
Heater. While pH control is critical, the control of alkalinity and calcium
hardness will protect against scaling and also help to prevent corrosion.
ACID
ALKALINE
HEATER
CAN BE
DAMAGED
CORROSIVE
WATER IDEAL
RANGE ALKALINE
WATER
0 1 2 3 4 5 6 7 7.2-7.8 8 9 10 11 12 13 14
HEATER
CAN BE
DAMAGED
The correct level of sanitizer, pH, total alkalinity and calcium hardness will very, depending
on the type of pool (plaster, fiberglass or vinyl) and the chemical content of the fill water.
Water that is out of balance can damage your pool heater and void the warranty. This
heater is not for use in salt water pools.
PROTECTING YOUR COATES HEATER
WITH PROPER WATER CHEMISTRY
WATER CHEMISTRY
PLUMBING CONNECTIONS
Page 8

TB1 FOR REMOTE TEMPERATURE
CONTROL (IF USED).
CR7
CR7
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
SINGLE PHASE
208V – 24 & 30kW
240V – 24 & 30kW
2.
COIL
COIL
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
HEATING ELEMENTS
PL1 "ELEMENT"
MODEL CPH
1BC2430H
1.
CR7
COIL
W
W
RB
RB
WW
RB
RB
#8
#8
#8 #8
#8
#8
#10 #10 #10
F1 F1 F1 F1 F1 F1
CR7
COIL
#10 #10 #10
#10 #10 #10
K7
31
TIMER
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
F5
F5
FLOW
RS2
TS1
PL4 "RESET”
PL2
"FLOW"
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
TB1 FOR REMOTE TEMPERATURE
CONTROL (IF USED).
FLOW SWITCH
CR7
CR7
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
SINGLE PHASE
208V – 12, 15 & 18kW
240V – 12, 15 & 18kW
3.
COIL
COIL
IDENTIFICATION.
4. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;5.
W = WHITE
HEATING ELEMENTS
PL1 "ELEMENT"
MODEL CE
F5
F5
6. HEATING ELEMENT QTY/RATING;
12kW = 2 @ 6kW
15kW = 1 @ 6kW & 1 @ 9kW
18kW = 2 @ 9kW
1BC1218G
1
2
CR7
COIL
W
W
RB
RB
WW
RB
RB
#8
#8
#8 #8
#8
#8
#8#8
#8
#8#8
#8
#10 #10 #10
#10
#10
#10
F1 F1 F1 F1 F1 F1
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NOCOM
K8
FLOW
RS2
TS1
PL4 "RESET”
PL2
"FLOW"
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
Page 9

TB1 FOR REMOTE TEMPERATURE
CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER
GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
SINGLE PHASE
208V – 54 & 57kW
240V – 54 & 57kW
2.
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
HEATING ELEMENTS
PL1 "ELEMENT"
MODEL PHS
1BC5457H
1.
W
W
RB
RB
WW
RB
RB
WW
RB
RB
WW
RB
RB
#10
#10
#10
#10
CR7
COIL
CR7
COIL
CR7
COIL
CR7
COIL
CR7
COIL
CR7
COIL
F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1
CR7
COIL
CR7
COIL
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
ISOLATED
BUS
NO COM
K8
K7
31
TIMER
F5
F5
FLOW
RS2
TS1
PL4 "RESET”
PL2
"FLOW"
K7
31
TIMER
K7
31
TIMER
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
TB1 FOR REMOTE TEMPERATURE
CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER
GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
SINGLE PHASE
208V – 36 & 45kW
240V – 36 & 45kW
2.
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
HEATING ELEMENTS
MODEL PHS
1BC3645G
1.
W
W
RB
RB
WW
RB
RB
F1 F1 F1
F1
#8
F1 F1 F1 F1
F1F1
CR7
COIL
WW
RB
RB
CR7
COIL
CR7
COIL
CR7
COIL
CR7
COIL
CR7
COIL
CR7
COIL
#10
#10
#10
#10 #10 #10
#10
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
#8 #8 #8 #8 #8 #8 #8 #8 #8
Page 10

TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
208V – 18kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;
4.
W = WHITE
#8
HEATING ELEMENTS
PL1
"ELEMENT"
MODEL CE
F5
F5
BR
BR
WW
3B18F
1.
C
BA
#8 #8
#8#8 #8
CR7
COIL
CR7
COIL
CR8
COIL
F1 F1 F1
F1 F1 F1
#8
#8 #8 #8 #8 #8 #8
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NOCOM
K8
FLOW
RS2
TS1
PL4 "RESET”
PL2
"FLOW"
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
CR7
CR7
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
208V – 12 & 15kW
240V – 12, 15 & 18kW
2.
COIL COIL
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
MODEL CE
F5
F5
BR
BR
WW
#10
3BC1218F
1.
C
BA
#8 #8
#10
#10
#8 #8 #8
#8 #8 #8
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
Page 11

TB1 FOR REMOTE TEMPERATURE
CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
208V – 36 & 45kW
240V – 36 & 45kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
PL1 "ELEMENT"
MODEL PHS
BR
BR
WW
3BC3645G
1.
C
BA
#8 #8
CR7
COIL
CR7
COIL
F1 F1 F1
F1 F1 F1
#8 #8 #8 #8 #8 #8
WW
RB
RB
CR7
COIL
F1 F1 F1
CR7
COIL
CR7
COIL
#8 #8 #8
#8 #8 #8
#8 #8 #8
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
208V – 24 & 30kW
240V – 24 & 30kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;
4.
W = WHITE
#8
HEATING ELEMENTS
PL1
"ELEMENT"
MODEL CPH
F5
F5
BR
BR
WW
3BC2430G
1.
C
BA
#8 #8
#8#8 #8
CR7
COIL
CR7
COIL
CR8
COIL
F1 F1 F1
F1 F1 F1
#8
#8 #8 #8 #8 #8 #8
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
RS2
TS1
PL4 "RESET”
PL2
"FLOW"
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
Page 12

TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
CR7
CR7
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
480V – 12, 15 & 18kW
2.
COIL COIL
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
MODEL CE
F5
F5
BR
BR
WW
#10
3J1218J
1.
C
BA
#8 #8
#10
#10
#8 #8 #8
#8 #8 #8
X3 X1
240V
T5
F6
XF
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
TB1 FOR REMOTE TEMPERATURE
CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
208V – 54 & 57kW
240V – 54 & 57kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
PL1 "ELEMENT"
MODEL PHS
BR
BR
WW
3BC5457H
1.
C
BA
#8 #8
F1 F1 F1
F1 F1 F1
#8 #8 #8 #8 #8 #8
WW
RB
RB
F1 F1 F1
#8 #8 #8
#8 #8 #8#8 #8 #8
CR8
COIL
WW
RB
RB
F1 F1
F1
CR8
COIL
CR8
COIL
CR8
COIL
CR8
COIL
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
Page 13

TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
480V – 36kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
PL3 "ELEMENT"
MODEL PHS
F5
F5
BR
BR
WW
3J36H
1.
C
BA
#8 #8
#8
#8 #8
CR7
COIL
CR7
COIL
#8 #8 #8
#10
#10
#10
BR
BR
WW
X3 X1
240V
T5
F6
XF
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
CR7
CR7
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
480V – 24 & 30kW
2.
COIL COIL
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
MODEL CPH
F5
F5
BR
BR
WW
5. HEATING ELEMENT QTY/RATING
24kW = 2 @ 12kW
30kW = 2 @ 15kW
#10
3J2430H
1.
C
BA
#8 #8
#10
#10
#8 #8 #8
#8 #8 #8
X3 X1
240V
T5
F6
XF
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
ISOLATED
BUS
Page 14

TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
480V – 54 & 57kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;
4.
W = WHITE
#8
HEATING ELEMENTS
PL3 "ELEMENT"
MODEL PHS
F5
F5
BR
BR
WW
3J5457H
1.
C
BA
#8 #8
#8#8 #8
CR7
COIL
CR7
COIL
CR8
COIL
F1 F1 F1
F1 F1 F1
#8
#8 #8 #8 #8 #8 #8
BR
BR
WW
BR
BR
WW
X3 X1
240V
T5
F6
XF
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
TB1 FOR REMOTE TEMPERATURE CONTROL (IF USED).
GROUND
POOL
GROUND
ENCLOSURE
TERMINAL
HEATER GROUND
SEE INSTRUCTION MANUAL FOR COMPONENT
THREE PHASE
480V – 45kW
2.
WW
RB
RB
IDENTIFICATION.
3. ALL WIRING TO BE 105°C INSULATED, MINIMUM.
CONTROL CIRCUIT WIRING; 14 AWG.
POWER CIRCUIT WIRING; AS NOTED.
B = BLACK
R = RED
LEGEND;4.
W = WHITE
#8
HEATING ELEMENTS
PL3 "ELEMENT"
MODEL PHS
F5
F5
BR
BR
WW
3J45H
1.
C
BA
#8 #8
#8
#8 #8
CR7
COIL
CR7
COIL
CR8
COIL
F1 F1 F1
F1 F1 F1
#8
#8 #8 #8 #8 #8 #8
BR
BR
WW
X3 X1
240V
T5
F6
XF
#2
BRASS
#1
COPPER
#3
ALUMINUM
1234
NO COM
K8
FLOW
J4
J3
TS3 J1
J2
AC
AC
CNO
J9
BW R
TEMP
Page 15

LIMITED WARRANTY
The company extends this limited warranty to the original purchaser of a Coates Electric Pool Heater.
Coates warrants the electrical components* and wiring (excluding enclosure, enclosure parts, knobs and accessories) in this
new Pool Heater to be free from defects in materials and workmanship for one (1) year from the provable date of purchase,
or eighteen (18) months from date of factory shipment, whichever occurs first. Coates further warrants the stainless steel
water containment vessel to be free from defects in materials and workmanship for two (2) years from the provable date of
purchase or thirty (30) months from the factory shipment, whichever occurs first. Enclosure, enclosure parts, knobs and
accessories have no warranty whatsoever.
*Exception: Factory installed heating elements are warranted for ninety 90 days from the date of heater installation, or
eighteen (18) months from date of factory shipment, whichever occurs first.
COATES will repair or replace at its option, defective component parts as explained above, during the warranty period
provided such parts are returned to the factory, freight prepaid. Factory authorization MUST BE OBTAINED under this
warranty before returning such defective parts.
Limited Warranty Does Not Cover
1. New products purchased outside the United States of America and Canada.
2. Uncrating, unpacking, set-up, installation and / or startup of this unit.
3. Adjustments to controls normally operated by consumer, purchaser or installer.
4. This limited warranty does not extend to any defect, malfunction or failure caused by, or resulting from improper
service, maintenance or repair, abuse, neglect, accident, corrosion caused by improper water chemistry or by
equipment that use salt to create a sanitizer, lack of water, or any other cause beyond the control of Coates
Heater Company, Inc. or to any product where the nameplate shall have been removed, altered, replaced, defaced or
rendered illegible.
5. This limited warranty is void if the Heater is used in a salt water system or under any extreme or unusual
corrosive condition for which stainless steel metals would not be recommended.
6. This limited warranty does not extend to the repair or replacement of defective components except at COATES or a
service facility authorized by COATES
IMPLIED WARRANTIES, WHEN APPLICABLE, SHALL COMMENCE UPON THE SAME DATE AS THE EXPRESS
WARRANTY PROVIDED ABOVE, AND SHALL, EXCEPT FOR WARRANTIES OF TITLE, EXTEND ONLY FOR
THE DURATION OF THE EXPRESS WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW
LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THE ONLY
REMEDY PROVIDED TO YOU UNDER AN APPLICABLE IMPLIED WARRANTY AND THE EXPRESS
WARRANTY SHALL BE THE REMEDY PROVIDED UNDER THE EXPRESS WARRANTY, SUBJECT TO THE
TERMS AND CONDITIONS CONTAINED THEREIN.
COATES SHALL NOT BE LIABLE FOR INCIDENTAL AND CONSEQUENTIAL LOSSES AND DAMAGES, UNDER
THE EXPRESS WARRANTY, ANY APPLICABLE IMPLIED WARRANTY, OR CLAIMS FOR NEGLIGENCE,
EXCEPT TO THE EXTENT THAT THIS LIMITATION IS FOUND TO BE UNENFORCEABLE UNDER APPLICABLE
STATE LAW.
SOME STATES DO NOT ALLOW THE EXCLUSION OF LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.
HEATER COMPANY, INC.
P.O. Box 1750
Kent, WA 98035
P/N 90007001 1/12
Other manuals for CE SERIES
1
This manual suits for next models
38
Table of contents
Other Coates Swimming Pool Heater manuals
Popular Swimming Pool Heater manuals by other brands

Koriks
Koriks 60 kW pool heater Installation and user manual

T.I.P.
T.I.P. SPH 10000 Translation of original operating instructions

Brasch
Brasch BH-933 Series instructions

Pentair Pool Products
Pentair Pool Products MiniMax CH 150 Operation & installation manual

Hayward
Hayward ENP2M-9A Installation instructions manual

Raypak
Raypak VERSA 155C Operating and installation instructions