Comelit RF10VEDO User manual

Passion.Technology.Design.
EN
TECHNICAL
MANUAL
The modules operate in two-way mode (reception
and transmission). This makes it possible to pair
radio controls, radio alarm sensors (contacts and/or
volumetric detectors) and supervised wireless sirens
with the control panel.
Art. RF10VEDO / RF32VEDO complies
with standards EN50131-1, EN50131-3,
EN50131-5-3
Technical manual for two-way radio expansion devices on
bus Art.RF10VEDO / RF32VEDO
• Install the equipment by carefully following the
instructions given by the manufacturer and in compliance
with the standards in force.
• All the equipment must only be used for the purpose it
was designed for. Comelit Group S.p.A. declines any
responsibility for improper use of the apparatus, for any
alterations made by others for any reason or for the use
of non-original accessories or materials.
• Installation, mounting and assistance procedures for
electrical devices must only be performed by specialised
electricians.
• For standard-compliant installation, a suitable (two-pole)
device must be provided for isolating and protecting the
mains power supply in the building's electrical system
(see Figure), in compliance with current standards (law
46/90): for example, a two-pole overload circuit breaker
with rated current 6A.
WARNING
Control
panel
PHASE
230 V
50 Hz
NEUTRAL
EARTH
Wiring diagram: two-pole mains switch (for
example overload circuit breaker with rated
current 6A) able to isolate the power supply of
the device.
Two-pole isolating
device example:
• Cut off the power supply before carrying out any
maintenance work.
• It is recommended to check the correct operation of the
safety system periodically (at least once a month).
• Remove any dust accumulated in the control panel
housing with a damp cloth, without using any solvent,
and check that there are no foreign bodies.
Maintenance
• All the products comply with the requirements of
Directive 2006/95/EC (which replaces Directive 73/23/
EEC and subsequent amendments), as certified by the
CE mark they carry.
• Art. VEDORF complies with standards EN50131-1,
EN50131-3, EN50131-5-3
• All the system components must have safety grade 2
or higher to obtain grade 2 alarm system certification
according to standard EN50131.
Certifications
• All items have a product ID label. An example is provided
below:
Product labels
interpretation serial number: 000PWWYYXXXXXXXX
protocol number
date of manufacture
week of manufacture (WW)
and year of manufacture (YY)
(in the sample label
1515= week 15 of the year 15)
VEDORF
000P1515XXXXXXXX
EAN article
identification
code
manufactur-
er's name
serial number
article
code
serial number
article
code
VEDORF
000P1515XXXXXXXX
• Check the condition of the connectors and the
conductors.
• Perform the maintenance and operation tests of all
components (smoke sensors, movement sensors, ...) as
indicated in the relevant technical manuals.
• Replace the protections on the terminals.

1
2
3
4
4
1. Dip Switch
2. Anti-tear tamper
3. Anti-tamper tamper
4. Holes for fixing the VEDORF card to metal housing
Art. BOXMETAL
MAIN FEATURES
• Up to 10 radio zones (RF10VEDO) or 32 radio
zones (RF32VEDO)
• Up to 8 radio outputs (RF10VEDO) or 16 radio
outputs (RF32VEDO)
• Up to 16 radio controls (RF10VEDO) or 32 radio
controls (RF32VEDO)
• Possibility of bidirectional communication
• Operating frequency in 868 MHz band, FSK
mode
• Sensor and siren status monitoring
• Separate management of intruder and sabotage
alarms
• Radio device power supply monitoring, including
sirens
• Monitoring
TECHNICAL SPECIFICATIONS
Features Value
Name of manufacturer /
supplier Comelit Group S.p.A.
Dimensions (b x h x d) 126 x 80 x 32 mm (in the
housing)
Weight
137 g with housing and
screws for fixing to the wall
35 g card alone
Consumption (min./max.) 55 mA medium, 60 mA max
Operating voltage 10 - 15 V
Operating temperature
and Operating humidity
-10° / + 55° with warm
dry air
-10° / + 40°C with max +
93% RH (not condensed)
Certifiable safety grade 2 according to EN50131-1*
Device Type TYPE B according to
standard EN50131-3
Environmental class II according to EN50131-1
* When observing any configuration and installation instructions
provided
CONFIGURATION JUMPERS
Name Function
JP1 If activated, enables 485 bus terminal resistor
JP3 Reserved
JP6 If activated, disables anti-removal (anti-tear)
tamper
JP7 If activated, disables anti-opening tamper
DIP switches 1 to 4 are for addressing the module
on the bus. On the current version, only addresses 1,
2 and 3 are used, so DIP switches 3 and 4 must be
left set to OFF.
TERMINAL BLOCK DESCRIPTION
ADDRESSING
SETTING THE SPEED OF THE CARD ON THE BUS
Name Function
V+ Power supply positive input
V- Power supply negative input
ARS485 data bus - A
BRS485 data bus - B
No. DIP1 DIP2 DIP3 DIP4
1OFF OFF OFF OFF
2ON OFF OFF OFF
3OFF ON OFF OFF
BAUD DIP5 DIP6
9600 OFF OFF
38400 ON OFF
57600 OFF ON
115200 ON ON
Note that the standard speed of the bus for VEDO
control panels is 38400 baud.
Name Flashing Meaning
D4
fast
(50 ms ON / 50 ms
OFF)
expansion connected
slow
(200 ms ON / 200 ms
OFF)
expansion not
connected
LED MEANINGS
2

MOUNTING EXPANSION UNIT ART. RF10VEDO /
RF32VEDO IN PLASTIC HOUSING FOR EXPAN-
SION DEVICES
The expansion devices on bus Art. RF10VEDO
/ RF32VEDO are supplied complete with plastic
housing which complies with EN50131; they can
therefore also be installed outside BOXPLASTIC and
BOXMETAL products.
The housing can be fixed to the wall or mounted
in flush-mounted boxes on the wall. A pre-marked
section on the bottom is for routing the cables
through, and another pre-marked section in the
top right-hand corner, coinciding with a fixing hole,
provides anti-tear protection.
The expansion module is fixed to the base of the
Wall mounting holes
Optional fixing holes
Pre-marked optional fixing holes Card fixing holes
Anti-tear tamper hole
Cable inlet hole
To ensure anti-tear protection, the hole
associated with the pre-marked area
with anti-tear function must always be
anchored to the wall. Failure to anchor this
section will make the anti-tear protection
useless.
IMPORTANT: when refitting the expansion
card in its housing, make sure that the
anti-tear tamper (the one furthest to the
left as shown in the illustrations on page
4) is held properly closed by the tab
originating from the pre-marked anti-tear
area of the housing.
In order to guarantee compliance with
Standards EN50131-1 and EN50131-
3, the expansion devices RF10VEDO /
RF32VEDO, if installed outside the control
panel housing, must have their anti-
sabotage and anti-tear contacts enabled,
and so the jumpers on the expansion must
be disconnected.
housing with 2 self-tapping screws.
The cover is secured to the base by means of three
fasteners on the top and two spring clips at the
bottom. There are also two safety screws to prevent
accidental opening.
Expansion device Art. RF10VEDO /
RF32VEDO cannot be mounted inside
metal housing Art. BOXMETAL.
MOUNTING EXPANSION UNIT ART. VEDORF IN A
HOUSING ART. BOXPLASTIC
For information regarding Art.
BOXPLASTIC, please refer to the technical
manual for the Vedo system.
2
1
3CLACK!
3

1st edition 07/2020
code 2G40002562
www.comelitgroup.com
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy
CERTIFIED MANAGEMENT SYSTEMS
4
1
2
3
2
2
1
1
3
2
RF10VEDO
RF32VEDO
1 2 3
PREPARING THE PLASTIC HOUSING FOR MOUNTING OF EXPANSION DEVICE ART.RF10VEDO / RF32VEDO
FIXING THE PLASTIC HOUSING TO THE WALL FOR MOUNTING OF EXPANSION DEVICE ART.RF10VEDO / RF32VEDO
1
2
3
2
1
2
1
3
1
2 3
This manual suits for next models
1