Commend GE 800 User manual

GE 800
VERSION 1.1/1209
PRODUCT MANUAL
ENGLISH

GE 800
21.1/1209
Manufacturer’s Reference:
This equipment fulfils the requirements of the EU standard 89/336/EWG 89/336/EWG
(EN 55022/55024).
Therefore this equipment is CE-labelled.
Please keep this description in safe custody!
Application:
With regard to the CE mark, the Intercom Server is suitable for the following types of application: residen-
tial buildings, office and commercial premises, small businesses and industrial premises with public low-
voltage mains supply.
Attention:
Defective power cables of the transformer may not be repaired or changed. In case of defective power cab-
les, the whole transformer must be changed.
Mounting and installation of the centrals and of the equipment may be carried out by authorised service
personnel only.
Cards may be exchanged only while the voltage is switched off.
Before exchanging of cards, ESD precautions must be observed. The Earth terminal of the instal-
lation board G8A-GEN (see page 51) is used as grounding point for Wrist Strap Grounding.
GE 800
Version: 1.1/1209
Number of pages: 60

GE 800
1.1/1209 3
Content
Quick Start Guide 5
1. Extent of Supply 6
2. Additional Components 7
General 7
3. Assembly of components 8
Intercom Server GE 800 8
Plug-in positions of the Cards 8
Installation of plug-in cards 9
Installation Boards for GE 800 9
4. Cabling 10
Connection Intercom Server 10
Connection of IP-Intercom Terminals 11
Connection of Intercom Terminals (Digital, Analogue) 11
Connection Inputs/Outputs 13
Connection of multiple Intercom Servers GE 800 15
5. CCT-Configuration 19
Configuration via IP or RS 232 19
Networking of housings 19
Start-up of a Networked System 20
6. Licensing 23
General 23
The Licensing Process 26
Licensing in CCT 27
Licence Website 31
Licence activation at the Intercom Station 33
7. Configuration of IP-Terminals 34
System Requirements 34
Network Requirements 35
The Program IPStationConfig 35
Compatibility IP-Terminals – IPStationConfig 36
Installation 36
The Program Interface 37
Firmware Download 38
Configuration 39
Configuration CCT 44
General Information 46
Expansion 46
Line length Subscribers 46
Standard Call Numbers 47
Dynamic Audio Channel Allocation 48
Technical Data 49
Intercom Server Basic Housing GE 800 49
Power supply card G8-GEN 49
Processor Card G8-GEP 50
Networking Card G8-NET 50
LED-Status Indication 51
Power Supply Card G8-GEN 51
Processor Card G8-GEP 51
Networking Card G8-NET 52
Subscriber Cards 54
Input / Output Cards 55
Examples 57
IP-Addresses 57
IP-Addresses with Subnetting 58
Router configuration with NAT 59
Technical Support 60

GE 800
41.1/1209

GE 800 Quick Start Guide
1.1/1209 5
Quick Start Guide
The Intercom Server GE 800 has been designed to meet the internal communication demands of large
companies and organisations. Different functions of modern internal communication such as intercom,
information and control can be integrated into a single system. By means of different subscriber cards
with different feature levels and additional interfaces the central can be adapted to the individual needs
with ease.
This manual describes mounting of the hardware and start-up of the Intercom Server, Subscriber In-
terfaces and Input/Output cards. Information about the interface cards and Intercom Terminals can be
found in the respective Manuals of the products.
The following steps are required for Start-up:
This manual is split into the following areas:
1. Extent of Supply
2. Additional components
3. Assembly of the components
4. Cabling
5. CCT Configuration
6. Licensing
7. Configuration of IP-Terminals
Installation of plug-in cards
and installation boards
Connection of
IntercomTerminals
Activation of
Licences
Configuration of:
- Features
- IP-Terminals
- Networks
Connection of
additional Servers
(only in networked systems)
Configuration of Server-IDs
and IP addresses
(only in networked systems)

1. Extent of Supply GE 800
61.1/1209
1. Extent of Supply
1 Intercom Server GE 800 incl.:
19" Housing: 3 HE with snap-on lid
G8-GEB Bus PCB (with 17 slots, of which 14 are empty)
G8-GEN Power Supply Card (incl. installation board G8A-GEN)
G8-GEP Processor Card
G8-NET Networking Card (incl. installation board G8A-NET, 1m Cable)
Tool for removing of installation boards
CD „Software & Manuals“
Country specific power supply
The desired transformer (incl. mounting set for DIN rail (TS 35)) can also be ordered separately:
Type: Power supply:
C-GE800 without transformer
C-GE800EU Transformer 230 V Europe
C-GE800AU Transformer 230 V Australia
C-GE800UK Transformer 240 V UK
C-GE800US Transformer 120 V USA
Type: Power supply:
X-PA7-230VEU Transformer 230 V Europe
X-PA7-230VAU Transformer 230 V Australia
X-PA7-240VUK Transformer 240 V UK
X-PA7-120VUS Transformer 120 V USA

GE 800 2. Additional Components
1.1/1209 7
2. Additional Components
General
Additionally to the Intercom Server for Start up of the system the following components are required:
1. Subscriber Cards
Subscriber cards handle the speech communication as well as subscriber specific functions. For
connection of IP-, Digital- and Analogue subscribers various cards in 4 feature level (B, C, D and P)
are available. The cards of the higher levels contain all the features of the lower ones plus additio-
nal features. With feature level P individual feature levels can be advised to each subscriber.
2. VoIP-Cards
Due to the support of wide spread standards such as the SIP or IAX protocol various VoIP telepho-
nes or entire VoIP telephone systems can be connected to the Intercom system as subscribers with
VoIP cards.
3. Input / Output Cards
Input / output cards are used for the reading in of floating contacts and / or operating of controls
such as door openers or barriers via floating relay contacts (depending on type
controls such as door openers or barriers via floating relay contacts (depending on type).
4. Interface Cards
For integration and connection of external systems such as telephones, PCs, mobile radios, etc.
5. Connection / Network Cards
For connection / networking of Intercom Servers via LAN/WAN (TCP/IP), 2-wire lines, ISDN, multi-
plexer/ mediaconverter or the public telephone network. Connection: restricted features. Networ-
king: full range of features, centrals operate as though in one location.
6. Installation Boards
For connection of the plug-in cards with the Intercom Terminals, Interfaces, Inputs, Outputs...
7. Licenses
With licenses the functionality of the Intercom Server and the plug-in cards can be expanded.
These components must be ordered separately according to customer requirements.
Please make sure all required components are at hand before beginning with assembly.

3. Assembly of components GE 800
81.1/1209
3. Assembly of components
1. Remove lid
2. Install plug-in cards
3. Install Installation Boards
Intercom Server GE 800
The included plug-in cards G8-GEN, G8-GEP and G8-NET are pre-installed in the Intercom Server.
Attention: Cards may be exchanged only with voltage switched off.
Plug-in positions of the cards
The plug-in cards can be inserted in the following slots:
GEN GEP 12345678910 11 12 13 14 NET max.. per
housing:
G8-16A 99999999999999 -143
G8-16E 99999999999999 -14
G8-8E8A 99999999999999 -143
G8-CNET-E1 -------
9999999 -5
G8-LAN -------
9999999 -7
G8-CNET-W -------
9999999 -5
G8-AUD 99999999999999 -14
G8-IAX 99999999999999 -14
G8-IF 99999999999999 -14
G8-IP 99999999999999 -14
G8-TEL4 19-9-9-9-9-9-9-- 2
G8-GED 99999999999999 -14
G8-GEN 9- -------------- - 1
G8-GEP 9-------------- - 1
G8-GET 99999999999999 -14
G8-NET -------------- 91
G8-S0 99999999999999 -14
G8-SELCALL 299999999999999 -4
G8-TEL 99999999999999 -14
G8-V24 99999999999999 -14
G8-V24-PRO 99999999999999 -14
G8-V24-PROIP 99999999999999 -14
1Details see datasheet G8-TEL4
2A second slot of the GE 800 is occupied by the G8-V24-PRO delivered with the G8-V24-PRO.
3A maximum of 100 outputs may be switched on at the same time.

GE 800 3. Assembly of components
1.1/1209 9
Installation of plug-in cards
The plug-in cards are inserted into the 19" housing from the front panel side and fixed with the attach-
ment-clips. The corresponding installation boards are mounted at the rear of the central.
Installation Boards for GE 800
The plug-in cards can be used with the following installation boards:
9...available separately
0...included in Extent of Supply
E...via ethernet port on G8A-NET
G8A-C G8A-I G8A-K G8A-T G8A-V24 G8A-GEN G8A-NET G8A-TEL G8A-PRO G8A-EW
G8-16A 99
G8-16E 99
G8-8E8A 99
G8-CNET-E1 0
G8-LAN E
G8-CNET-W 0
G8-AUD 9*999*
G8-IF E
G8-IP E
G8-TEL4 99
G8-GED 9999
G8-GEN 0
G8-GEP E
G8-GET 9999
G8-NET 0
G8-S0 0
G8-SELCALL 0
G8-TEL 0
G8-V24 0
G8-V24-PRO 0
G8-V24-PROIP 0
G8-VOIPSERV 0
* At installation boards G8A-C and G8A-T the four relay outputs of the G8-AUD are not carried out.
Installation boards
Plug-in cards Tool for removing
of installation
boards

4. Cabling GE 800
10 1.1/1209
4. Cabling
1. Connection Intercom Server
2. Connection Intercom Terminals
3. Connection Inputs /Outputs
4. Connection of multiple Intercom Servers
Connection Intercom Server
Installation Board G8A-GEN
Installation Board G8A-NET
G8A-GEN
1
2
3
4
5
6
7
8
9
+30V
24V AC
24V AC
S1WS1W
S2
S1
IN2
IN1
MU2
MU1
S2WS2W
S1S1
S2S2
Music /
alarm
input
Floating
contacts
Grounding point
for wrist strap
grounding
Programming socket
(parallel to G8-GEN)
Door opener
e.g.:
Power supply
Wiring outputs
Grounding
1....GND
(Shield)
2....TXD
3....RXD
4....NC
5....GND
6....NC
7....NC
8....NC
9....NC
Power supply GE 800
DC
or
AC
UPLINK
DOWNLINK
OUT (GEV)
IN (GEV)
Ethernet (configuration)
Connection to network cards (G8-CNET-W, G8-CNET-E1)
or GE 700 (G7-GEV)

GE 800 4. Cabling
1.1/1209 11
Connection of IP-Intercom Terminals
For IP-Subscribers no additional installation boards are required. Communication to the Intercom
Server is carried out via the G8-NET Card: (G8A-NET installation board).
The G8-IP is connected to the network (switch) via the RJ 45 sockets “UPLINK” or “DOWNLINK” on
the installation board G8A-NET
Configuration see ”7. Configuration of IP-Terminals” on page 34
Connection of Intercom Terminals (Digital, Analogue)
For digital and analogue Intercom Terminals installation boards are required for connection to the
Intercom Server (see ”Installation Boards for GE 800” on page 9).
Installation Board G8A-C for 4 Subscribers
NC = not connected
At DSP-Subscriber cards G8-GED only A and B are connected.
Connection over patch panel
Between G8A-C and the patch panel a standard CAT5-cable, e.g. ASK KAT5/1 (1m, 3.3 ft) or ASK KAT5/
5 (5m, 16.4 ft) of our selection should be used, because these cables are not cross-jointed. A standard
intercom cable can be used between socket and intercom station (the cables, that are delivered with
each station, are cross-jointed).
Switch
GENGEP
G8-NET
GE 800
IP
GEV
G8A-C
AB
NC
D
NC NCNC
C
1st subscriber
2nd subscriber
3rd subscriber
4th subscriber
Plug connection
G8A-C EE 411 / EE 811A
patch panel
socket
Standard CAT 5
cable
Standard
intercom
cable

4. Cabling GE 800
12 1.1/1209
Installation Board G8A-T for 8 Subscribers
At DSP-Subscriber cards G8-GED only A and B are connected. The first subscriber of each slot can also
be connected over the RJ45 sockets or over screw terminals (e.g. for test purposes or feed in of music).
Installation Board G8A-I for 4 Subscribers
At DSP-Subscriber cards G8-GED only A and B are connected.
Installation Board G8A-K for 4 Subscribers
At DSP-Subscriber cards G8-GED only A and B are connected.
G8A-T
A1 B1
C1 D1
A2 B2
C2 D2
A3 B3
C3 D3
A4 B4
C4 D4
A1
A1
A1
A1
A1
B1
B1
B1
B1
C1
C1
C1
C1
D1
D1
D1
D1
B1
C1 D1
A2 B2
C2 D2
A3 B3
C3 D3
A4 B4
C4 D4
NC NC
NC NC
NC
(16.4 ft or 32.8 ft)
Colour code
Slot n
Slot n+1
Slot n Slot n+1
1st subscriber 1st
:A1
:B1
:C1
:D1
2nd
:A2
:B2
:C2
:D2
3rd
:A3
:B3
:C3
:D3
subscriber
whiteblue whiteyellow: A1
blue brown: B1
whiteblue whiteyellow: C1
yellow black: D1
subscriber 2nd subscriber
whiteblue whitegreen: A2
green blue: B2
whiteblue whitegreen: C2
brown yellow: D2
subscriber 3rd subscriber
whiteblue whitegreen: A3
black green: B3
whiteyellow whitegreen: C3
blue brown: D3
4th subscriber 4th subscriber
whiteyellow: A4 whitegreen: A4
yellow: B4 black: B4
whiteyellow: C4 whitebrown: C4
green: D4 blue: D4
parallel to D-Submin
5m or 10m cable
Slot n
Slot n
Slot n+1
Slot n+1
G8A-I
A1 B1
C1 D1
A2 B2
C2 D2
A3 B3
C3 D3
A4 B4
C4 D4
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
5m or 10m cable
1st subscriber
whiteblue: A1
blue: B1
:C1
yellow: D1
2nd subscriber
:A2
green: B2
:C2
brown: D2
3rd subscriber
:A3
black: B3
whiteyellow: C3
:D3
whiteblue
whiteblue
whiteblue
whiteblue
blue
4th subscriber
whiteyellow: A4
yellow: B4
whiteyellow: C4
green: D4
Colour code
(16.4 ft or 32.8 ft)
D1A2D3A4
C1B2C3B4
B1C2B3C4
A1D2A3D4
NC
NC
NC
NC
NCNCNC NC NC
NCNCNC NC NC

GE 800 4. Cabling
1.1/1209 13
Connection Inputs/Outputs
Connection G8-8E8A
Installation Board G8A-I
Installation Board G8A-K
Connection G8-16A
Installation Board G8A-I
G8A-I
S1
S2
S3
S4
S5
S6
S7
S1W
S2W
S3W
S4W
S5W
S6W
S7W
S8W S8
S2
S1
S3 S4
IN2
IN4
IN6
IN1
IN3
IN5
IN7 IN8
NC
NC
NC
NC NC
5m or 10m cable
(16.4 ft or 32.8 ft)
Colour code
Outputs Inputs
: S1W
:S1
: S2W
:S2
: S3W
:S3
: S4W
:S4
: S5W
:S5
: S6W whitebrown
:S6
whiteblue whitegreen:IN1
blue blue: IN2
whiteblue whitegreen:IN3
yellow yellow: IN4
whiteblue whitegreen:IN5
green green: IN6
whiteblue whitegreen:IN7
brown brown: IN8
whiteblue whitegreen:
black black:
whiteyellow
blue blue:
whiteyellow: S7W
yellow: S7
whiteyellow: S8W
green: S8
whiteyellow:
brown:
whiteyellow:
black:
S1
S2
S3
S4
IN1
S1W
S1
S1
Internal cabling:
Connection:
S2S3WS6S7W
S2WS3S6WS7
S1S4WS5S8W
S1WS4S5WS8
S1
S2
S3
S4
IN1IN5IN7 IN7 IN3
IN2IN6IN8 IN8 IN4
G8A-I
S1
S2
S3
S4
S5
S6
S7
S1W
S2W
S3W
S4W
S5W
S6W
S7W
S8W S8
S9
S9W
S10W S10
S12
S14
S16
S11
S13
S15
S11-16W S11-16W
5m or 10m cable
(16,4 ft or 32,8 ft)
Colour code
Outputs S1 -S1 0 Outputs S1 1-S1 6
: S1W
:S1
: S2W
:S2
: S3W
:S3
: S4W
:S4
: S5W whitegreen:
: S5 black:
: S6W whitebrown:
: S6 blue:
whiteblue whitegreen:S11
blue blue: S12
whiteblue whitegreen:S13
yellow yellow: S14
whiteblue whitegreen:S15
green green: S16
whiteblue whitegreen:S11-16W
brown brown: S11-16W
whiteblue
black
whiteyellow
blue
whiteyellow: S7W
yellow: S7
whiteyellow: S8W
green: S8
whiteyellow: S9W
brown: S9
whiteyellow: S10W
black: S10
Internal cabling:
Internal cabling:
At tention:
As the outputs S11 to S16
have a common root, the
equipment to be connected
must have a common
reference point.
S1W
S1
S11
S12
S11-16W

4. Cabling GE 800
14 1.1/1209
Installation Board G8A-K
Connection G8-16E
Installation Board G8A-I
Installation Board G8A-K
S2S3WS6S7W
S2WS3S6WS7
S1S4WS5S8W
S1WS4S5WS8
S9W
S9
S10W
S10
S11S15S11-16W S13
S12S16S11-16W S14
S11-16W
S11-16W
G8A-I
IN2
IN4
IN6
IN1
IN3
IN5
IN7 IN8
IN10
IN12
IN14
IN9
IN11
IN13
IN15 IN16
5m or 10m cable
(16,4 ft or 32,8 ft)
Colour code
whiteblue whiteyellow:
blue brown:
whiteblue whiteyellow:
yellow black:
whiteblue whitegreen:
green blue:
whiteblue whitegreen:
brown yellow:
whiteblue whitegreen:
black green:
whiteyellow whitegreen:
blue brown:
whiteyellow: IN13 whitegreen:
yellow: IN14 black:
whiteyellow: IN15 whitebrown:
green: IN16 blue:
:IN1
:IN2
:IN3
:IN4
:IN5
:IN6
:IN7
:IN8
:IN9
: IN10
: IN11
: IN12
IN1
Connection:
IN4IN5IN12IN13
IN3IN6IN11IN14
IN2IN7IN10IN15
IN1IN8IN9IN16

GE 800 4. Cabling
1.1/1209 15
Connection of multiple Intercom Servers GE 800
The G8-NET Card
Multiple GE 800 Servers are connected via the Uplink and Downlink ports of the G8-NET card
For the G8-NET card no special configuration is necessary
A special “Discovery protocol” is used to localize the other GE 800 servers in the local network
Connection possibilities
VLAN
If the GE 800 Intercom Servers are connected via a switch, the switch must be VLAN capable.
The following VLAN-IDs must be allowed: 1, 254 and 255
Depending on the type of the switch these IDs must be configured
Switches with Autonegotiation
If both the Intercom Server and the switch are configured to “Autonegotiation” in certain cases the con-
nection can not be built-up.
The solution for this is a fixed configuration, e.g. “100 MBit / full duplex” (see ”Configuration of IP-Net-
work Settings” on page 21)
Attention: For this purpose the following IP address range is reserved!
231.255.x.233 to 231.255.x.239 x...Intercom Server-ID
with switch without switch
If more than 20 servers shall be connected a switch is
required (max. 105 GE 800).
Up to 20 GE 800 can be directly connected in series via the
G8-NET card (no switch required).
Advantages: - No restrictions for IP-Subscriber cards
- Redundant connections possible (see page 16)
- No additional costs
Disadvantages: - Increased cost / power consumption - When one GE 800 in the chain fails the rest of the chain
is disconnected as well
Restrictions: - Up to max. 105 GE 800 in LAN - Up to max. 20 GE 800
- No GE 800 fully equipped with IP-subscriber cards
Uplink
Downlink
OUT
IN
G8A-NET
Uplink
Downlink
OUT
IN
G8A-NET
Uplink
Downlink
OUT
IN
G8A-NET
Uplink
Downlink
OUT
IN
G8A-NET
1
2
3
...
20

4. Cabling GE 800
16 1.1/1209
Network Redundancy
It is possible to connect a network redundancy via a second cable from the second ethernet port of the
G8-NET. If one cable to the switch is defect, the second connection automatically takes over.
Note: For network redundancy the switch must support Rapid Spanning Tree RSTP functionality!
Required Bandwidth in the Network
The connection of GE 800 Intercom Servers creates a load on the IP network with the speech and con-
nection data. These must be regarded when planning the system together with the network admini-
strator.
One 16 kHz conversation requires 146 kBit/s
The advisable load of a 100 Mbit/s network = 40 Mbit/s
Therefore 40 Mbit/s can be transmitted in the network
This bandwidth minus the bandwidth already used in the network is available for the Intercom
system
Always plan a reserve!
Example
40 Mbit/s = 270 conversations between two segments when no other load is on the network

GE 800 4. Cabling
1.1/1209 17
Networking with existing systems
The GE 800 Intercom Server is connected to the GE 700 via the two GEV-Ports on the G8A-NET instal-
lation board of the G8-NET Card.
Example 1:
Example 2:.
P
OWER
CPU
NET
SLO
T
1
SLO
T
2
SLO
T
3
SLO
T
4
SLO
T
5
SLO
T
6
SLO
T
7
SLO
T
8
SLO
T
9
SLO
T
10
SLO
T
11
SLO
T
13
SLO
T
14
GEN
GEP
Slot 01
Slot 02
Slot 03
Slot 04
Slot 05
Slot 06
Slot 07
Slot 08
Slot 09
Slot 10
Slot 11
Slot 12
Slot 13
Slot 14
NET
IP
GEV
P
OWER
CPU
NET
SLO
T
1
SLO
T
2
SLO
T
3
SLO
T
4
SLO
T
5
SLO
T
6
SLO
T
7
SLO
T
8
SLO
T
9
SLO
T
10
SLO
T
11
SLO
T
13
SLO
T
14
GEN
GEP
Slot 01
Slot
02
Slot 03
Slot 04
Slot 05
Slot 06
Slot 07
Slot 08
Slot 09
Slot 10
Slot 11
Slot
12
Slot A
Slot B
GEV
GE 800
GE 700
P
OWER
CPU
NET
SLO
T
1
SLO
T
2
SLO
T
3
SLO
T
4
SLO
T
5
SLO
T
6
SLO
T
7
SLO
T
8
SLO
T
9
SLO
T
10
SLO
T
11
SLO
T
13
SLO
T
14
GEN
GEP
Slot 01
Slot
02
Slot 03
Slot 04
Slot 05
Slot 06
Slot 07
Slot 08
Slot 09
Slot 10
Slot 11
Slot
12
Slot A
Slot B
GEV
GE 700

4. Cabling GE 800
18 1.1/1209
Limitations in Mixed Systems
Limitations at GE 800
Must be inserted in the top-most GEV-ring
Can only be connected to Ring 1 of a GE700, no connection to Ring 2!
If the GE 800 is switched off the GEV-ring does not work -> no relay on G8-NET
Only one GEV connection of a GE 800 system to a GE 700!
Limitations at GE 700
GE 700 network cards must be upgraded to software version min. 5.2
Limitations with synchronous connections
Works like “Ring 2”: GE 800 always is “Clock Master”
If CNET-W or CNET-E1 networking is used in the GE 700 system, the Servers GE 800 may only be
connected on one side of the network!
Otherwise non-synchronous connections must be used (LAN, WAN, S0).
When G8-CNET-W or G8-CNET-E1 are connected to the GEV ring a connection to a GE 700 is not pos-
sible

GE 800 5. CCT-Configuration
1.1/1209 19
5. CCT-Configuration
Configuration via IP or RS 232
Configuration of GE 800 Intercom Servers can be carried out via a RS 232 or standard network cable.
For configuration of features see manual “PRO 800”.
IP (Ethernet)
Connect the PC for configuration with a network cable directly to the Intercom Server (ethernet port
on the installation board G8A-NET) or with a switch in the network.
In a network the Intercom Server and the PC must be in the same subnet.
The Intercom Server is automatically advised an IP-address during initialisation (see ”Configuration
of IP-Network Settings” on page 21)
RS232
For configuration via RS 232 a 9-way D-Submin extension cable (1:1, Plug: Server-side, socket PC-side)
is required.
This cable is connected to the 9-way D-Submin socket on the G8-GEN or the installation board
G8A-GEN.
NC = not connected
This cable can be purchased at an electric outfitter or ordered under the type ”X-KAB-CCT”.
Networking of housings
With networking cards G8-NET up to 105 housings can be networked to a local system, in which all
features of the GE 800 are available.
Additionally multiple locations can be networked via further network cards (G8-LAN, G8-S0,
G8-CNET-E1, ...).
The description of the individual network cards can be found in the respective manuals. Below only
networking via the G8-NET card is described.
One networking card G8-NET, one installation board G8A-NET and one 1 m connection cable ASK
KAT5/1 are included in the extent of supply of the basic housing GE 800.
GND 55
NC 44
NC 66
NC 77
NC 88
NC 99
RXD 33
TXD 22
NC 11
GE 800 PC
(9-way D-Submin plug) (9-way D-submin jack)

5. CCT-Configuration GE 800
20 1.1/1209
Start-up of a Networked System
In networked systems each Server housing must be advised a unique number (Server-ID). There are
two methods of advising each Intercom Server a Server-ID:
For a maximum of 14 housings the Server-IDs can be set via the DIP-switches of the G8-GEP. This is
the easiest method, because the PC does not need to be connected to each single housing.
The numbers can also be set with the program CCT, e.g. for more than 14 housings or if the program-
ming should be prepared in advance for a central.
Attention: The standard calling numbers, that are automatically allocated to the housings (see ”Stan-
dard Call Numbers” on page 47), must be changed by programming if more than 9 housings are con-
nected. Otherwise three- and four-digit numbers beginning with the same digits would occur (e.g. 110
in housing no. 1 and 1101 in housing no. 11).
Setting the numbers with DIP-switches
1. Initialize each housing with the desired number (1 to 14):
Set the DIP-switches 1 to 4 of the G8-GEP to “ON“.
Switch the Intercom Server off and back on.
Set the desired number (switch position see below).
Switch the Intercom Server off and back on.
2. Connect all housings. If all Server-IDs are set correctly the status LEDs of the G8-NET must signal
faultless operation (siehe Seite 52).
Attention: Initialising the Intercom Server resets the programming.
3. Connect the PC to any housing and read out the configuration of the Intercom Server with the
program CCT (Menu Intercom Server > Receive). Now all cards are recognised correctly and the
central can be configured as usual. For configuration the PC can be connected to any housing, all
housings are configured like a single housing.
Server-ID: DIP-switches: Standard
call numbers with
subscriber cards
with 4 subscribers:
Gehäuse-
nummer:
DIP-switches: Standard
call numbers with
subscriber cards
with 4 subscribers:
1234 1234
1 1000 101-148 8 0001 801-848
2 0100 201-248 9 1001 901-948
31100 301-348 10 0101 1001-1048 *
40010 401-448 11 1101 1101-1148 *
51010 501-548 12 0011 1201-1248 *
60110 601-648 13 1011 1301-1348 *
71110 701-748 14 0111 1401-1448 *
1=switch position “ON“, 0=switch position “OFF“
* Attention:
- The standard calling numbers, that are automatically allocated to the housings, must be changed by
programming if more than 9 housings are connected. Otherwise three- and four-digit numbers beginning
with the same digits would occur (e.g. 110 in housing no. 1 and 1101 in housing no. 11).
- At full expansion with IP-Subscribers (14 cards with 8 subscribers per card = 112 per housing) collisions
may already occur at the second housing (see ”Standard Call Numbers” on page 47)
Other manuals for GE 800
1