EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Compaq
  6. •
  7. Rack & Stand
  8. •
  9. Compaq AlphaServer DS10 User manual

Compaq AlphaServer DS10 User manual

Other manuals for AlphaServer DS10

3

Other Compaq Rack & Stand manuals

Compaq 2T-QINTL-TL Service manual

Compaq

Compaq 2T-QINTL-TL Service manual

Compaq 2T-QINTL-CD Service manual

Compaq

Compaq 2T-QINTL-CD Service manual

Compaq TFT450R Parts list manual

Compaq

Compaq TFT450R Parts list manual

Compaq DS10L - AlphaServer - 256 MB RAM User manual

Compaq

Compaq DS10L - AlphaServer - 256 MB RAM User manual

Compaq 2T-QINTL-18 Service manual

Compaq

Compaq 2T-QINTL-18 Service manual

Compaq 158223-B21 - StorageWorks Fibre Channel SAN Switch... User manual

Compaq

Compaq 158223-B21 - StorageWorks Fibre Channel SAN Switch... User manual

Compaq 2T-QINTL-70 Service manual

Compaq

Compaq 2T-QINTL-70 Service manual

Popular Rack & Stand manuals by other brands

Salamander Acadia AC/W/L400/WH Assembly instructions

Salamander

Salamander Acadia AC/W/L400/WH Assembly instructions

Fohhn VAT-09 Mounting instruction

Fohhn

Fohhn VAT-09 Mounting instruction

ricoo FS0522 quick start guide

ricoo

ricoo FS0522 quick start guide

AMSOIL BMK-22 Installation and service instructions

AMSOIL

AMSOIL BMK-22 Installation and service instructions

Kargo Master 48220 installation guide

Kargo Master

Kargo Master 48220 installation guide

Milestone AV Technologies SIMPLICITY SLF2 installation instructions

Milestone AV Technologies

Milestone AV Technologies SIMPLICITY SLF2 installation instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Ready-Set-Mount RSMCM602 instruction manual

Ready-Set-Mount

Ready-Set-Mount RSMCM602 instruction manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

Welch Allyn 48960 Assembly instructions

Welch Allyn

Welch Allyn 48960 Assembly instructions

Arkon CM035-ST-2 installation instructions

Arkon

Arkon CM035-ST-2 installation instructions

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

Agilent Technologies E2609B installation guide

Agilent Technologies

Agilent Technologies E2609B installation guide

Mustang MV-ARM4 installation guide

Mustang

Mustang MV-ARM4 installation guide

Mounting Solutions WRM-320 manual

Mounting Solutions

Mounting Solutions WRM-320 manual

ShelterIt 21208 installation instructions

ShelterIt

ShelterIt 21208 installation instructions

Pyle PMKSPAD1 manual

Pyle

Pyle PMKSPAD1 manual

SPL RackPack?4 1040 manual 

SPL

SPL RackPack?4 1040 manual 

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

1
EK–DS10S–RM. A01
ALPHASERVER DS10
RACKMOUNT GUIDE
Overview
•Rackmount Guidelines
•Unpack Rackmount Box
•Determine Base Zero
•Mark and Prepare the Rails
•Install the Rails
•Attach the Rackmount Ears
•Insert and Secure the System
•Check Power and Secure Cables
•For More Information
WARNING: To prevent injury, access is
limited to persons who have appropriate
technical training and experience. Such
persons are expected to understand the
hazards of working within this equipment
and take measures to minimize danger to
themselves or others.
Rackmount Guidelines.
•A maximum of six systems per each power
controller unit in a rackmount cabinet.
Unpack Rackmount Box
The rackmount box is one of three long boxes found
in the system’s shipping carton (see Figure 1). It
contains these instructions, two rails, U-clips and
screws, and two rackmount ears for securing the
system in the rack.
Figure 1 Unpacking the Rackmount Kit
PK1038-99
Determine Base Zero
Decide the relative position of the system in the rack.
Base zero is where the bottom of the system will be
when installed in the rack.
If your system is the first system in the rack, then
base zero is between the 6th and 7th hole up from the
floor of the rackmount cabinet. This distance allows
the system to clear the power controllers and provide
space for cable management.
If you are adding your system to a rack already
populated, then base zero is the top of the system
underneath the system to be installed. This system
needs a clearance of 9 holes to accommodate the
system height.
Mark and Prepare the Rails
•Using the template on the back of this card (
•Figure 9) mark holes 2 and 5 on an interior rail,
and base zero (see Figure 2).
Figure 2 Using the Template
PK1033-99
2
5
Base 0
Top
•Mark all four of the inner rails (see Figure 3).
•If you are installing more than one
AlphaServer DS10 in the rack at the same
time: using the template, mark the top of the first
system you are installing. Use this as base zero
for the second system, move the template up,
mark holes 2 and 5, and the top of this system,
until you have marked holes for all of systems
you are installing.
•Insert a U-clip at each hole you have marked.
Figure 3 Marking Inner Rails
PK1033a-99
2
5
Install the Rails
There are two threaded guide pins on the rails: one on
the front of each rail, and one on each rear side. In
case the holes in your rackmount cabinet require
smaller guide pins, a second set of smaller pins has
been included in the kit. Replace the pins if
necessary.
•Insert the front guide pin, aligning the screw hole
to the front C-clip. See Figure 4, ➊. Push the
rail in.
•Insert the rear guide pin into the side rail,
aligning the screw holes to the rear U-clips.
Push the rail in toward the side of the rackmount
cabinet (see ➋).
•Secure with four screws. See ➌.
Figure 4 Installing the Rails
PK1034-99
2
3
1
Attach the Rackmount Ears
•Align the three vertical holes located on the front
edge of the system with the three holes on the
rackmount ears (see Figure 5).
•Using a Phillips screwdriver, screw the ears onto
the system, finger tight. Do not apply excessive
force.
Figure 5 Attaching the Rackmount Ears
PK1035-99
Insert and Secure the System
•Using both hands, place the system onto the rails
and push it back into the cabinet (see Figure 6).
•Align the holes in the bulkhead with the prongs
on the rails (see Figure 7).
•Push the system back in to the rack.
•Secure the system by tightening the captive
screws on the rackmount ears on the front of the
system.
Figure 6 Inserting the System
PK1036-99
Caution: During removal, system box not tethered.
Attention: Pendant le déplacement, le boîtier système n'est pas fixé.
Precaución: Durante el traslado, no debe atarse la caja del sistema.
Achtung: Beim Entfernen ist das Systemgehäuse nicht gesichert.
PK1037-99
Figure 7 Aligning the System on the Rails
PK1042-99
Check Power and Secure Cables
•Select the correct power setting (see Figure 8).
•Connect the power cord.
•Turn the power cord latch clockwise to secure
the power cord.
•Tighten the latch with a screwdriver.
•Route the power cord over the back of the rail,
into the rackmount cabinet side area.
•Continue cabling (see AlphaServer DS10 Quick
Setup poster). When all cabling is complete,
connect power cord to the power controller unit.
Figure 8 Securing Power
115V
230V
PK1047-99
After securing the power cord with the safety latch,
route the power cords over the rails and into the side
of the cabinet.
For More Information
•H9A10-M-Series Cabinet, Illustrated Parts
Breakdown (EK-H9A10-IP)
•H9A15 M-Series Cabinet Illustrated Parts
Breakdown (EK-H9A15-IP)
•Printset H9A10 M-Series Cabinet AlphaServer
Systems Rack Mount Configurations (B-IB-
H9A10-5-DBM)
•Printset H9A15 M-Series Cabinet AlphaServer
Systems Rack Mount Configurations (B-IB-
H9A15-3-DB
0
1
2
3
4
5
6
8
7
Top
PK1039-99
Figure 9 Template for Side Rails