Competition SAC5B-CK Quick start guide

Operation and Installation Guide
LCC SYSTEM CONFIGURATION DIAGRAM ---------------------1
LCC SYSTEM ALL OUTDOORSTATION---------------------------3
VIDEO DOORPHONE ------------------------------------------------10
WIRING CONNECTIONS---------------------------------------------24
OPERATION-------------------------------------------------------------25
LCC SYSTEM ALL OUTDOORSTATION INSTALLATION----27
LCC SYSTEM ALL INDOORMONITOR INSTALLATION------30
TECHNICAL PARAMETER-------------------------------------------36

Outdoor
station 1
Outdoor
station 2
Outdoor
station 1
Outdoor
station 2
-1- -2-

Dimension: 58x135x39mm
Dimension: 58x135x39mm
Dimension: 97x130x43mm
Dimension: 55x130x43mm
Dimension: 97x130x43mm
SAC5B-CK B/W ..............................................................................
SAC5C-CK color ............................................................................
SAC800B-CK B/W .........................................................................
SAC800C-CK color .......................................................................
SAC25B-CK B/W ............................................................................
SAC25C-CK color ..........................................................................
SAC35B-CK B/W ............................................................................
SAC35C-CK color ..........................................................................
door lock indoor monitor
indoor monitor
-3- -4-

10-20
10-20
Time clock: Turn off codes group 10-20, 36-40
Functional explanation:
TMCLK is low level effective means in low level status lock the users'
passwords from 10-20, 36-40, only passwords located on position
01-09, 21-35 still can work. In the high level status, all codes groups
can work. .
Functional explanation:
EGR: Low level effective for trigger door open.
12V DC power supply
12V DC power supply
Dimension: 203x150x43mm
Dimension: 250x120x43mm
Dimension: 78x185x60mm
Normal open
Normal closed
Normal open
Normal closed
SAC551B-CK B/W .........................................................................
SAC551C-CK color .......................................................................
SAC50B-CK B/W ...........................................................................
SAC50C-CK color .........................................................................
SAC561B-CK B/W ........................................................................
SAC561C-CK color ......................................................................
Water cover
LED assistant
CCD camera
Speaker
Calling button
Microphone
Screw hole
Nameplate
Connection wiring
Protect the camerafrom outside water
Provide lighting duringnight time for
better visibility
Capture the imageto sent tothe monitor
Sound from themonitor is delivered
Call the indoorphone to communicate
Delivers and soundvoice when
communication with theindoor phone
Install the screws
Show residential name
Connection with themonitor
-5- -6-

Factory default setting is 5 seconds.
1. Enter programming mode.
2. Enter 00 (this is a special code group), two "Di Di" sounds as
reminder.
3. Enter a desired lock/delay operation time in a two digits fomat
(01 to 99 seconds).
4. Press the button to quit.
.
.
.
.
.
1. Shut down the power of the unit and keep pressing the button .
2. Switch on the power pressing the button down, the unit will then
give a long continuous tone.
3. When the tone stoped, another sounds will be heard and input your
new 4 digits programmers codes.
1. Press the button plus your 4 digits master codes
2. Your are successfully enter the programming mode when three
sounds is heard and the LED is flashing.
3. Press the button to quit.
1. Enter programming mode.
2. It is available for 40 groups code. 01 to 40 is the group number,
which should be input in front of the 4 digits codes from 31 to 40
group codes, input once 4 digits codes to open the door for a long
time until twice the same code to have it closed.
3. Input 4 digits codes, a two sounds is heard, it is unsuccessful and
indicating the code is existent at somewhere, if a three sounds is
heard, it is successfully set.
4. Press the button to quit.
.
.
.
.
.
1. The original factory defaulted programming
password is 1234.
2. Input a 4 digits password to have the door
striked or the lock unlocked.
Change the master code
Entering programming mode
Set the unlocking time
Add user codes
Camera lens
Power
Working electric current
Illumination
Communication duration
Communication method
Working temperature
IP rating
DC 14.5V
200mA
1/3 CCD 72degree ken
0.05 LUX
120s
Duplex communication type
55
o
-20 +55 C
Specifications of 50/561 series code access
-7- -8-

1. Enter programming mode.
2. Press the button # to hear a two "Di Di" sounds as reminder.
3. Input 4 digits codes that want to deleted.
4. It is successfully deleted after three sounds heard.
5. Press the button to quit.
1. Enter programming mode.
2. Press the button # hear a two "Di Di" sounds as reminder.
3. One more press the button # two sounds as reminder.
4. Continuously press the button # 7 times to delete all settings.
Unlocking time turns to onesecond. The admin codes as same
as before. After five sounds, all settings back to default.
5. Press the button to quit.
.
.
.
.
.
1. When connect more than one indoor monitor please short
circuit J2 of the far the most monitor and open J2 of the other
monitors.
2. When connect more than one indoor monitor please short
circuit J1 andJ3 of theclosest monitor andopen J1 andJ3 of
other monitors.
.
.
Handset monitor:
MT210B-CK2U MT210C-7CK2U MT200B/C-CK2
MT210B-CK2 MT210C-7CK2
Hand-free monitor:
MT320C-CK2 MT333C-CK2 MT18B/C-CK2
MT37XC-CK2U MT37XC-CK2 MT181B/C-CK2
MT350C-CK2 MT360C-CK2 MT360T-CK2
MT361C-CK2 MT361T-CK2 MT300C-CK2
MT8T-CK2
1. Enter programming mode.
2. Enter one of the codes groups from 01 to 40.
3. Press the button # to delete the codes of which position you just
input, eg. input 01, means delete the codes on the position 01.
4. It is successfully deleted when a three "Di Di" sounds heard as
reminder.
5. Press the button to quit.
.
.
.
.
Delete user codes
Delete a codes directly
Delete all settings
NO. NO.
Icon Description Icon Description
Microphone
Monitor
Door lock releasing
Talking
TFT display/CRT
Speaker
Talkingvolume
Brightness
Chroma/contrast
System terminal
Calling
Receiver
Indicated light
-9- -10-

Dimension: 220x110x25mm
Dimension: 190x113x43mm
Hand-free monitor: MT350C-CK2 Hand-free monitor: MT300C-CK2
-17- -18-

Dimension: 160x120x42mm
Dimension: 240x175x38mm
Hand-free monitor: MT360C-CK2 MT361C-CK2
Hand-free monitor: MT370C-CK2U MT370C-CK2
Dimension: 160x120x42mm
Hand-free monitor: MT360T-CK2 MT361T-CK2
Monitoring button & calling and monitoring
indicated light for one door entrance
Unlocking button & calling and monitoring
indicated light for two door entrance
Talking button & calling and power supply
indicated light
Talking button & calling and power supply
indicated light
Calling indicated light for one door entrance
Unlocking button & calling indicated light
for two door entrance
-19- -20-

Dimension: 240x175x38mm
Dimension: 240x175x38mm
Dimension: 240x175x38mm
Hand-free monitor: MT371C-CK2U MT371C-CK2
Hand-free monitor: MT372C-CK2U MT372C-CK2
Hand-free monitor: MT373C-CK2U MT373C-CK2
-21- -22-

A view of the front door can be
seen anytime the entrance
button is pressed and a dialogue
can be made with anyone at the
front door. .
OPERATION
Indoor monitor calltransferring
Call from indoormonitor
Press to end call.
Other indoor monitors ring. Press or pick upthe
handset, any indoor
monitor can talk with
outdoor station.
After talking,
press
-25- -26-

-27- -28-

-29- -30-

-31- -32-

MT8T
-33- -34-

1. Cables of LCC system: Non-wired cable. Diameter 0.5
2
mm , from outdoor station to the farthest monitor distance 70m.
2. Each monitor should be parallel connected. One monitor can be
extended 3 monitors as maximum extension. One monitor can be
connected 2 outdoor stations as maximum.
3. Handset monitor only has 2 functional buttons. Hand-free monitor
only has 2 functional buttons, not available for transferring-call
function.
4. Built-in power supply video door phone can working with input AC
votage directly. Non-built-in power supply needs plus a power
supply the specification is DC 14.5V 1.3A.
.
.
.
Voltage: DC14.5V
Voltage: DC14.5V
Voltage: DC14.5V
o
Temperature:-20 +55 C
Working current:100mA Stand by: 10mA
Mode: dual transmission Talkingtime: 2 minutes
2
Transmission distance 28m, wire 0.2mm
2
Transmission distance 50m, wire 0.3mm
2
Transmission distance 70m, wire 0.5mm
Dimension: 90x130x43mm (involvewaterproof)
2
Transmission distance 28m, wire 0.2mm
2
Transmission distance 50m, wire 0.3mm
2
Transmission distance 70m, wire 0.5mm
Mode: dual transmission
o
Temperature:-20 +55 C
Talkingtime: 2 minutes
Working current:100mA Stand by: 10mA
2
Transmission distance 28m, wire 0.2mm
2
Transmission distance 50m, wire 0.3mm
2
Transmission distance 70m, wire 0.5mm
Mode: dual transmission
o
Temperature:-20 +55 C
Talkingtime: 2 minutes
Working current:100mA Stand by: 10mA
MODEL: SAC25B/C-CK SAC35B/C-CK
MODEL: SAC5B/C-CK SAC551B/C-CK
MODEL: SAC50B/C-CK SAC561B/C-CK
-35- -36-

Voltage: DC14.5V
Voltage: DC14.5V
Voltage: AC100V 240V/50(60)Hz
2
Transmission distance 28m, wire 0.2mm
2
Transmission distance 50m, wire 0.3mm
2
Transmission distance 70m, wire 0.5mm
Dimension: 140x105x45mm (involvewaterproof)
o
Temperature:-20 +55 C
Working current:100mA Stand by: 10mA
Mode: dual transmission Talkingtime: 2 minutes
o
Temperature:-10 +55 C
Talkingtime: 2 minutes
Mode: dual transmission
Dimension: 240x175x38mm
Working current: 200mA Stand by: 20mA
o
Temperature:-10 +55 C
Mode: dual transmission Talkingtime: 2 minutes
Dimension: 220x110x28mm
Image display: 5.8"TFT
Working current: 600mA Stand by: 50mA Voltage: DC 14.5V
Voltage: DC14.5V
Voltage: DC14.5V
2
Transmission distance 28m, wire 0.2mm
2
Transmission distance 50m, wire 0.3mm
2
Transmission distance 70m, wire 0.5mm
Power supply: built-outpower supply ofPSU-SD5B-14V5 for
each indoor monitor.
Mode: dual transmission
Dimension: 160x120x42mm
o
Temperature:-10 +55 C
Talkingtime: 2 minutes
Dimension: 165x220x50mm
Working current: 600mA Stand by: 50mA
Mode: dual transmission
Image display: 4"TFT
o
Temperature:-10 +55 C
Talkingtime: 2 minutes
Dimension: 220x110x25mm
Working current: 600mA Stand by: 50mA
Mode: dual transmission
Image display: 5.8"TFT
o
Temperature:-10 +55 C
Working current: 500mA Stand by: 50mA
Talkingtime: 2 minutes
Voltage: DC14.5V o
Temperature:-10 +55 C
Mode: dual transmission Talkingtime: 2 minutes
Dimension: 160x120x42mm
Working current: 300mA Stand by: 50mA
MODEL: SAC800B/C-CK
MODEL: MT37 series
MODEL: MT333C-CK2
MODEL: MT360T-CK2 MT361T-CK2
MODEL: MT360C-CK2 MT361C-CK2
MODEL: MT18B/C-CK2 MT181B/C-CK2
MODEL: MT350C-CK2
Voltage: DC14.5V o
Temperature:-10 +55 C
Talkingtime: 2 minutes
Mode: dual transmission
Dimension: 198x243x79mm
Working current: 600mA Stand by: 50mA
MODEL: MT200 series
-37- -38-

Voltage: AC100V 240V/50(60)Hz
Voltage: DC14.5V
Dimension: 205x220x50mm
o
Temperature:-10 +55 C
Talkingtime: 2 minutes
Mode: dual transmission
Working current: 200mA Stand by: 20mA
o
Temperature:-10 +55 C
2
Transmission distance 28m, wire 0.2mm
2
Transmission distance 50m, wire 0.3mm
2
Transmission distance 70m, wire 0.5mm
Dimension: 245x160x18mm
Power supply: built-outpower supply ofPSU-SD5B-14V5 for
each indoor monitor.
Mode: dual transmission Talking time: 2 minutes
Working current: 700mA Stand by: 50mA
MODEL: MT210 series
MODEL: MT320C-CK2
Voltage: DC14.5V
Dimension: 198x95x45mm
o
Temperature:-10 +55 C
Talkingtime: 2 minutes
Mode: dual transmission
Working current: 250mA Stand by: 50mA
MODEL: MT8T-CK2
-39-
This manual suits for next models
31
Table of contents
Other Competition Intercom System manuals