Quantum QR5 Assembly instructions

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
INSTALLATION AND PROGRAMMING MANUAL
Rev. 1.09

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
INTRODUCTION AND WARRANTY
Pach & Co. thanks and congratulates you on the purchase of your Quantum QR5. The Quantum
QR5 is a residential and multi tenants telephone entry system.
The manual is designed to guide you through the detail in programming and use of the Quantum
QR5. It is important for you to read and follow the manual completely.
Pach & Co. new products are warranted to be free of defects in material or workmanship for a
period of two years, (24 months), from the date of purchase. This warranty extends only to
wholesale customers who buy direct from Pach & Co. or through Pach & Co.’s normal distribution
channels.
Pach & Co. does not warrant this product in any way to the end user consumer. Consumers must
obtain warranty information from the selling dealer and/or installer as to the nature of the dealer’s
warranty, if any. All contact to Pach & Co. from the end user consumer will be referred to the
consumer’s selling dealer and/or installer.
There are no obligations and/or liabilities on the part of Pach & Co. for consequential damages
arising out of or in connection with use or performance of Pach & Co. products or other indirect
damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or
reinstallation. Any use or change to Pach & Co. products not expressly approved by the
manufacturer, and performed by an authorized dealer/installer will immediately void the warranty.
All implied warranties, including warranties for marketability as well as implied warranties for
suitability, are valid only until the warranty expires or is voided, whichever comes first. Please visit
www.pach-co.com for the warranty in more detail.
SPECIFICATION
Hardware
Input power 12VAC/DC-18VAC/DC (12 VAC 40VA supplied)
Current consumption 500-750 mA
Single Line Liquid Crystal Display
Built-in Radio Frequency Receiver
Built-in 26 Bit Wiegand Card Reader
12 Vdc camera power
Lock and keys

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
Two on board relay
Two Auxiliary input
Operating environment 10ºF-140ºF
Relative Humidity 0%-95% non-condensing
Double 3/4" knock-out on the back and bottom panel
Dimension: 9-3/4"(L) x 6-3/8"(W) x 1-3/4"(D)
Features
100 access codes (4, 5, 6, 7, 8 digit) and 200 cards
10 temporary access codes valid 1-10 times
10 special access codes to hold open and close
10 programmable call forwarding phone number
Built-in 26 Bit Wiegand Card Reader and Radio Reader
Automatic call forwarding
Automatic card enrollment
Access code and card block programming
Two Auxiliary inputs
Two Door Sensors
600 event buffer (only available with TCP/IP Internet Explorer Browser programming)
Lighted keypad
INTRODUCTION TO QUANTUM QR5
Front View

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
Back View
WIRING DIAGRAM
Click on the label for more detail diagram

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
INPUT POWER - BATTERY BACKUP- CAMERA
Input Power:12-18 VAC/DC, 12VAC transformer is supplied
Type of wires 2-conductors 18 gauge stranded
Battery Backup: 12VDC 4Ahr
Type of wires 2-conductors 18 gauge stranded
Camera Power: 12 VDC on Board Power. Check the camera specification.
Type of wires 2-conductors 20 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
DOOR WIRING DIAGRAM
Two independent on board relay are available on the Quatum QR5, means you can control
two different doors independently. Each relay supports NO (normally open) and NC
(Normally Closed) contact. No power is supplied by the relays therefore you MUST supply
separate power for door strike. Check the voltage requirements with door strike
manufacturer or refer to door strike owner's installation manual. DO NOT share power with
the Quantum QR5.
Relay rating: 250VAC/12A, 120VA/15A, 24VDC/15A. The relay supplies normally open (NO)
and normally closed (NC).
Wiring requirement: 18 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
TELEPHONE WIRING DIAGRAM
1. Using an existing telephone line.
Wiring requirements: 18 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
2. Using a DSL line.
Wiring requirements: 18 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
3. Using a Dedicated Phone Line
Wiring requirements: 18 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
4. As an Intercom
Wiring requirements: 18 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
AUXILIARY INPUT, DOOR SENSOR, RS-485 AND WIEGAND DIAGRAM
Wiring requirements:
See manufacturers specification
RS-485 requires 2-conductors category 5 or 2-conductors 18 gauge stranded

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
The Quantum QR5 has built-in 26 bit Wiegand card reader, however if you need to use
different card reader, you may do so by disconnecting the existing card reader and replace
with your own 26-bit wiegand card reader as shown on the diagram.
Warning: Compatibility issue may occur.
FIRMWARE UPGRADE CONNECTOR
This connector is used to upgrade the firmware and only use by the manufacturer. Do not
attempt to upgrade the firmware, doing so will void the warranty.

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
MASTER CODE RETRIEVAL BUTTON
The default Master Code is 0000. If case the Master Code has been forgotten, you may
press and release the button to log on to programming, the screen will show as below
SPEAKER AND MICROPHONE
Speaker = 8.7 ohm
Microphone = 1.542 kOhm
RADIO RECEIVER
The Quantum QR5 has built-in Radio Frequency (RF) Receiver. The transmitter is not
included.
POWER SWITCH
The power switch must be in the OFF (left position) during the installation to avoid any
damages to the board. Check all the wiring, then turn the power switch ON (right position).
The system will initialize and the display will show scrolling message as shown partially
below

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]
EARTH GROUND
Wiring requirement: 16-18 gauge wire. Connect the earth ground wire into one of the door
hinge stud.
KEYPAD LAYOUT AND FUNCTIONALITY
The Quantum QR5 has built-in lighted keypad but no alphabetical lettering. Use the
template below for reference.

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/Quantum%20QR5.htm[5/6/2010 3:12:40 PM]

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/system%20programming.htm[5/6/2010 3:12:44 PM]
SYSTEM LOCAL PROGRAMMING
Log-on to programming
mode 16 Auto unlock schedule 33 Temporary Codes
00 Change master Code 17 Time zones 34 Unlock hold using codes
01 Call forwarding directory 18 Holiday time zones 35 Temporary cards
02 Edit existing directory 20 Aux-in 1 36 Unlock hold using card,
fob or transmitter
03 Delete directory 21 Aux-in 2 37 Initiating premise call
04 Delete all directories 22 Do not disturb 38 System answer mode
06 New access code 23 Lock out count 39 Enable/disable remote
access
07 Delete access code 24 Alarm mode 40 Remote access number
door1
08 Delete all access codes 25 Keypad press beep 41 Remote access number
door2
09 Access code digit 26 Door beep 42 Relay 2 mode
10 New card and transmitter
enrollment 27 Talk time 43 Do not disturb time zones
11 Delete card 28 Door 1 open time 45 Manual unlock timer
12 Delete all cards 29 Door 2 open time 46 Firmware Version
13 Set time 30. Enable or Disable Call
Forwarding 50 Erase memory to default
14 Set date 31 Call forwarding time 51 Edit welcome screen
15 Initializing event buffer 32 Automatic Call forwarding
directory
Log-on to programming mode

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/system%20programming.htm[5/6/2010 3:12:44 PM]
In case the master code is not available, refer to Master code retrieval button, then click wiring
diagram link.
00 Change master code
It is recommended to replace the default password (0000) for security purposes. The master
code must be 4-digit.

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/system%20programming.htm[5/6/2010 3:12:44 PM]

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/system%20programming.htm[5/6/2010 3:12:44 PM]
01 Call forwarding directory
10 call forwarding directories can be programmed in the system. The call forwarding can be
used to call direct or as an automatic call forwarding based on the programming on function
code: 32 Select call forwarding directory. The call forwarding will not work if the system is
installed as an intercom, refer to the wiring diagram.

INSTALLATION AND PROGRAMMING MAN
file:///C|/PACH%20&%20COMPANY/QUANTUM%20MANUAL%202009/Quantum%20QR5-1/system%20programming.htm[5/6/2010 3:12:44 PM]
02 Edit existing directory
In case of making mistake on Function Code 01, then use this function code to make changes.
Other manuals for QR5
1
Table of contents
Other Quantum Intercom System manuals
Popular Intercom System manuals by other brands

Panasonic
Panasonic VL-SWD701KL Quick reference guide

CENTURION SYSTEMS
CENTURION SYSTEMS G-ULTRA quick guide

Fanvil
Fanvil i30 user manual

Fbt
Fbt MAD4 IP user manual

urmet domus
urmet domus 1148 Series Installation, programming and functions manual

Trigon Electronics
Trigon Electronics MiniGuard IID Programming guide