3. DIMENSIONS (mm)
4. SPECIFICATIONS
INPUTS
Connection: 1 or 3 phase, 3 wire, unrestricted
POWER FACTOR: Unity - to lead or lag zero
POWER CALIBRATION SPAN: 170 to 8500 Watt/Var
OVER RANGE: +42% (at full accuracy)
CURRENT
CURRENT RANGES: 0 - 1 to 0 - 5 Aac RMS
CURRENT OVER RANGE: +20% (at full accuracy)
PEAK OVERLOAD: 40 Aac RMS, for 5 sec. every 10
min. 50 Aac RMS, for 30 sec, every 10 minuets (opt.)
VOLTAGE
VOLTAGE RANGES: 0 - 85 to 0 - 500 Vac
VOLTAGE OVER-RANGE: +20% (at full accuracy)
VOLTAGE OVERLOAD (maximum 600 Vac):
Withstand 1.6 x [nom. rating] continuous, limited to 600Vac
POWER SUPPLY
SUPPLY RANGES: 115, 230 Vac -15/+25%
POWER OVERLOAD: Withstand 1.45 x [nom.
INPUT BURDEN
CURRENT: 0.26 VA @ 5 Aac
VOLTAGE: 0.15 VA @ 150 Vac, 0.3 VA @ 300 Vac
VOLTAGE (Vab) (at Self-power config.): 2.6 VA @ 150 Vac
SUPPLY: 2.4 - 2.6 VA @ 150/300 Vac at 20 mA output
ISOLATION:
Current Inputs: 2.5 KV RMS /1 minute
Voltage and power Inputs: 4KV RMS /1 minute
FREQUENCY RANGE: 45 - 440 Hz
FREQUENCY VARIATION EFFECT: < 0.02%/Hz for Watt output
< 0.1%/Hz for Var output
OUTPUTS (Watt or Var)
OUTPUT SPANS: -20 to +20mA, 0..1 to 0/4..20 mA
MAXIMUM OUTPUT LOAD: Rload KΩ= 16/Iout (mA)
LOAD VARIATION EFFECT: < ±0.03% (for full change)
RESPONSE TIME: < 200 msec (10-90% of span)
ACCURACY
±0.1% of span (typical), ±0.25% of span (max)
TEMPERATURE
OPERATING: -5 to +65°C
STORAGE: -35 to +85°C
TEMPERATURE STABILITY: Better than ±0.05/1°K
HUMIDITY: 5 - 95% relative, non condensed
HOUSING: Plastic Polycarbonate
PROTECTION LEVEL:
Box: According to IP-40
Terminals: According to IP-20
WEIGHT: 0.6 Kg