Contrik XO CCV5RD Series User manual

Instruction manual
Power Strip XO
CCV5RD-*
UNMATCHED RELIABILITY AND SAFETY
EN

2Instruction manual |BDA 681
CONTRIK IPower Strip XO ICCV5RD*
1. General
Product group:
CCV5RD-6T1-C | article code 1027454
CCV5RD-6T1-2C | article code 1027455
The information in this manual applies exclusively to
the devices described in this manual and all variants
of the CONTRIK CCV5RD series. Depending on
the design of the devices and due to different
components, there may be optical deviations with
the illustrations in the manual.
In addition, the devices may differ from each other
functionally or in their operation. In addition to
these operating instructions, other instructions (e.g.
device components) may be included in the scope of
delivery, which must be observed in full. In addition,
improper use can cause hazards such as short circuits,
fire, electric shock, etc. Only pass the product on to
third parties in its original packaging or with this
operating manual.
For the safe use of the product, the national, legal
regulations and provisions (e.g. accident prevention
and occupational health and safety regulations as
well as environmental regulations) of the respective
country must also be observed. All company names
and product designations contained herein are
trademarks of their respective owners. All rights
reserved.
For safety and approval reasons (CE), you may not
modify and/or change the product. The product is
not intended for use in the medical field. The product
is not intended for use in explosive or flammable
environments.
Please pay attention to the national regulations:
For Germany, it is a mobile equipment and
therefore the instructions of the DGUV
regulation 3 have to be followed.
2. Check delivery
• Power distributor
CONTRIK
Power Strip XO - Power distributor PGD-0004

3Instruction manual |BDA 681
CONTRIK IPower Strip XO ICCV5RD*
3. Safety instructions
Read the operating instructions
carefully and observe the safety
instructions in particular.
If you do not follow the safety
instructions and the information on
proper handling in this operating
manual, we will not accept any
liability for any resulting personal
injury/property damage.
In addition, the warranty/guarantee
will be voided in such cases.
This symbol means: Read the
operating instructions.
• The product is not a toy. Keep it away from
children and pets.
• To avoid clamping injuries and burns at high
ambient temperatures, it is recommended to wear
safety gloves.
• It voids the warranty, in case of manual
modifications of the device.
• Protect the product from extreme temperatures,
direct sunlight, strong vibrations, high humidity,
strong jets of water, falling objects, flammable
gases, vapors and solvents.
• Do not subject the product to very high mechanical
stress.
• If safe operation is no longer possible, take the
product out of operation and protect it from
unintended use. Safe operation is no longer
guaranteed if the product:
shows visible damage,
no longer functions properly,
has been stored under unfavorable
environmental conditions for an extended period
of time, or
has been subjected to considerable transport
stresses.
• Handle the product with care. The product may be
damaged by shocks, impacts or dropping.
• Also observe the safety instructions and operating
instructions of the other devices that are connected
to the product.
• There are parts inside the product that are under
high electrical voltage. Never remove covers.
There are no user-serviceable parts inside the unit.
• Never plug in or unplug power plugs with wet
hands.
• Only use a proper 5-pole CEE mains plug removed
by a qualified electrician as the voltage source.
• 5-pin CEE mains socket (400 V/AC, 50 Hz).
• When supplying power to the device, make sure
that the cable cross-section of the connecting
cable is sufficiently dimensioned according to local
norms.
• Never connect the product to the power supply
immediately after it has been moved from a cold
room to a warm room (e.g. during transport). The
resulting condensation water can possibly destroy
the device or lead to an electric shock! Allow the
product to come to room temperature first.
• Wait until the condensation water has evaporated,
this may take several hours. Only then may the
product be connected to the power supply and
put into operation.
• Do not overload the product. Observe the
connected load in the technical data.
• Do not operate the product covered! At higher
connected loads, the product heats up, which
can lead to overheating and possibly fire when
covered.
• The product is only de-energized when the mains
plug is pulled out.
• Make sure that the product is de-energized before
connecting a device to it.
• The mains plug must be disconnected from the
socket under the following conditions:
before cleaning the product
during thunderstorms
when the product will not be used for an
extended period of time.
Never pour liquids on or near the product.
There is a high risk of fire or fatal electric shock.
If liquid should nevertheless get inside the device,
immediately switch off all poles of the CEE mains
socket to which the product is connected (switch
off fuse/automatic circuit breaker/FI circuit breaker
of the associated circuit). Only then disconnect the
mains plug of the product from the mains socket
and contact a qualified person. Do not operate the
product any longer.
In commercial facilities, observe the
local accident prevention regulations.
For Germany:
German Federation of Institutions for Statutory
Accident Insurance and Prevention (Verband
der gewerblichen Berufsgenossenschaften) for
electrical systems and equipment. In schools,
training centers, hobby and do-it-yourself
workshops, the handling of electrical equipment
must be supervised by trained personnel.

4Instruction manual |BDA 681
CONTRIK IPower Strip XO ICCV5RD*
• Contact a specialist if you have any doubts about
the operation, safety or connection of the product.
• Have maintenance, adjustment and repair work
carried out exclusively by a specialist or a specialist
workshop.
• If you still have questions that are not answered
in these operating instructions, contact our
technical customer service or other specialists.
4. Requirements for fitter and
operator
The operator is responsible for the proper use and
safe operation of the manifold. When the manifold
is operated by non-professionals, the installer and
operator must ensure that the following requirements
are met:
• Ensure that the manual is permanently stored and
available at the manifold.
• Ensure that the layperson has read and understood
the instructions.
• Ensure that the layperson is instructed in the
operation of the manifold before using it.
• Ensure that the layperson only uses the distributor
as intended.
• Ensure that persons who cannot assess the dangers
involved in handling the distributor (e.g. children
or persons with disabilities) are protected.
• Ensure that a qualified electrician is consulted in
the event of malfunctions.
• Ensure that the national accident prevention and
work regulations are observed.
5. Product description
Unit design and variants
Variants
Example: CCV5RD-6T1-C
Pos. Description
AOutput: CEE 16 A 6 h 3L+N+E 415 V *
BpowerCON®TRUE1®TOP output with
self-closing hinged cover
CInput: CEE 16 A 6 h 3L+N+E 415 V
* Only for variant: CCV5RD-6T1-2C
ABC

5Instruction manual |BDA 681
CONTRIK IPower Strip XO ICCV5RD*
6. Commissioning
The activities described in this chapter may only be
carried out by a qualified electrician! If the instrument
is connected to a supply line with insufficient cable
cross-section and / or insufficient back-up fuse, there
is a danger of fire, which can cause injuries or an
overload, which can cause damage to the instrument.
Observe the information on the type plate! Check the
connection of the sockets.
Supply the power distributor with power via the
connection.
Switch on the protective devices.
7. Operation
The device is designed for professional use and is not
suitable for use in households.
Only use the device as described in these operating
instructions. Any other use, as well as use under other
operating conditions, is considered improper and may
result in personal injury or property damage.
No liability is accepted for damage resulting from
improper use.
The device may only be used by persons who have
sufficient physical, sensory and mental capabilities as
well as appropriate knowledge and experience. Other
persons may only use the device if they are supervised
or instructed by a person responsible for their safety.
Only distributors with a degree of protection that
corresponds to the degree of protection required at
the place of use may be used.
8. Maintenance, inspection and
Cleaning
• The housing, mounting materials and suspensions
must not show any signs of deformation. Cleaning
of the interior of the device may only be carried
out by qualified personnel.
• Please check the local regula-
tions for the product inspection details.
For Germany:
According to DGUV regulation 3, this inspec-
tion must be carried out by a qualified electri-
cian or an electrically instructed person using
suitable measuring and testing equipment.
A period of 1 year has proven to be the testing
interval. You must determine the interval in accord-
ance with DGUV Regulation 3 Implementation
Instructions to suit your actual operating condi-
tions. The range is between 3 months and 2 years
(office).
• Switch off the product before cleaning. Then
disconnect the plug of the product from the mains
socket. Then disconnect the connected consumer
from the product.
• A dry, soft and clean cloth is sufficient for cleaning.
Dust can be easily removed using a long-haired,
soft and clean brush and a vacuum cleaner.
• Never use aggressive cleaning agents or chemical
solutions, as this may damage the housing or
impair the function.
9. Disposal
Electronic devices are recyclable
materials and do not belong in
household waste.
Dispose of the product at the end of
its service life in accordance with the
applicable legal requirements.
By doing so, you fulfill the legal
obligations and make your
contribution to environmental
protection.
Send the device to the manufacturer
for disposal free of charge..

6Instruction manual |BDA 681
CONTRIK IPower Strip XO ICCV5RD*
10. Technical data
General specifications
Supply voltage 415 V/AC, 50 Hz
Rated current 16 A
Output connections powerCON®TRUE1®TOP /
CEE 16 A 6 h 3L+N+E 400 V*
*~ nur bei CCV5RD-6T1-2C
Protection class IP65
Operating temperature -25 bis +70°C
Relative humidity Indoor:
95 % at –5 °C to +30 °C
70 % at +35 °C
57 % at +40 °C
Outdoor:
100 % at –25 °C to +27 °C
60 % at 35 °C
46 % at 40 °C
Dimensions approx. 528.6 x 92 x 117.2 mm
Label:
Pos. Description
1Article description
2QR code for further options such as: Manual
3Protection class (IP)
4Rated voltage
5Number of outer conductors
6Input connector
7Serial number (& batch number)
8Product group
9Mandatory self-declaration (WEEE Directive)
10 CE marking
11 Part number
Further technical data can be found in the corresponding
data sheets or at
www.contrik.com
1
9
10
8
7
3 4
11
5 6
2

7Instruction manual |BDA 681
CONTRIK IPower Strip XO ICCV5RD*
Imprint
Subject to change due to technical progress! These operating instructions correspond to the state of
the art at the time of product delivery and not to the current development status at Neutrik.
If any pages or sections of these operating instructions are missing, please contact the manufacturer
at the address given below.
Copyright ©
This user manual is protected by copyright. No part or all of this user manual may be reproduced,
duplicated, microfilmed, translated or converted for storage and processing in computer equipment
without the express written permission of Neutrik.
Copyright by: © Neutrik® AG
Document Identification:
Documenten No.: BDA 681 V1
Version: 2023/02
Original Language: German
Manufacturer:
Connex GmbH / Neutrik Group
Elbestraße 12
DE-26135 Oldenburg
Germany
www.contrik.com

www.contrik.com
BDA 681 V1 - Power Strip XO -EN - 2023/01 – Data subject to change without prior notice. © 2023 Neutrik AG.
UNMATCHED RELIABILITY AND SAFETY
LIECHTENSTEIN (HEADQUARTERS)
Neutrik AG, Im alten Riet 143,
9494 Schaan, Liechtenstein
GERMANY / NETHERLANDS / DENMARK / AUSTRIA
Neutrik Vertriebs GmbH, Felix-Wankel-Straße 1,
85221 Dachau, Germany
GREAT BRITAIN
Neutrik (UK) Ltd., Westridge Business Park, Cothey Way Ryde,
Isle of Wight PO33 1 QT
FRANCE
Neutrik© France, 52 Rue d’aguesseau,
92100 Boulogne
USA
Neutrik Americas., 4115 Taggart Creek Road,
Charlotte, North Carolina, 28208
JAPAN
Neutrik Limited, Yusen-Higashinihonbashi-Ekimae Bldg., 3-7-19
Higashinihonbashi, Chuo-ku, Tokyo 103
HONG KONG
Neutrik Hong Kong LTD., Suite 18,
7th Floor Shatin Galleria Fotan, Shatin
CHINA
Ningbo Neutrik Trading Co., Ltd., Shiqi Street, Yinxian Road West
Fengjia Village, Hai Shu District, Ningbo, Zhejang, 315153
SWITZERLAND
Contrik AG, Steinackerstrasse 35,
8902 Urdorf, Switzerland
Table of contents