GENERAL INFORMATION
The timing capacity is 100 hours to 1 second. The unit may be set to count
down and alarm, or count up and alarm. A “thru-zero” feature counts to the
programmed time, alarms, and counts up. A memory function recalls the last
programmed time. An audible alarm sounds for one minute when a
programmed time is reached. A isual alarm flashes constantly until
manually turned off. A timeout feature allows the timer to be stopped for “off”
periods and restarted. The clock mode displays time-of-day to the second,
has a time-of-day alarm, and sounds an hourly signal.
COUNT DOWN ALARM TIMING
1. Press the MODE key until TMR appears on the display. If the timer is
running, press the STOP key to stop the timer. Press the RESET key to
clear the display to zero. Press the (▲▼) key until ▼ appears on the
display (▼ indicates count down timing).
2. Press the number keys 0 through 9 to set desired hours, minutes and
seconds. Example: to set 89 hours, 53 minutes, 27 seconds—press
8,9,5,3,2,7. Example: to set 12 minutes, 32 seconds—press 1,2,3,2.
Example: to set 58 seconds—-press 58.
3. When the desired amount of time appears on the display, press the
START key to begin timing down.
4. When the timer reaches zero an electronic tone will sound and the
display will flash TIME’S UP. The tone will sound for one minute and
then turn oft automatically to preser e battery life. To turn the audible
alarm off manually, press any key. At zero the timer begins timing up.
This feature displays the amount of time which has elapsed since zero.
When the alarm is sounding, the first press of any key turns off the
electronic tone. Then press the STOP key to stop the UP timing. Press
RESET to clear the display: The timer will only clear when time is
stopped.
CORRECTING AN ENTRY
If an error is made during an entry, press the RESET key to clear the display
to zero. If you wish to clear an entry when time is running, you must first stop
the timing by pressing the STOP key, then press the RESET key. The timer
will only clear when time is stopped.
COUNT UP ALARM TIMING
1. Press the MODE key until TMR appears on the display. If the timer is
running, press STOP to stop the timer. Press the RESET key to clear
the display to zero. Press the (▲▼) key until ▲ appears on the
display (▲ indicates count up timing).
2. Press the number keys 0 through 9 to set desired hours, minutes and
seconds. Example: to set 89 hours, 53 minutes, 27 seconds—press
8,9,5,3,2,7. Example: to set 12 minutes, 32 seconds—press 1,2,3,2.
Example: to set 58
3. When the desired amount of time appears on the display, press the
START key to begin counting up. The timer automatically starts at zero
and begins counting up.
4. When the programmed time is reached an electronic tone will sound and
the display will flash TIME’S UP. The tone will sound for one minute
and then turn off automatically to preser e battery life. To turn the
audible alarm off manually, press any key. When the programmed time
is reached, the display returns to zero and begins timing up. This
feature displays the amount of time which has elapsed since the
programmed time has been reached. When the alarm is sounding, the
first press of any key turns off the electronic tone. Then press the
STOP key to stop the UP timing. Press the RESET key to clear the
display. The timer will only clear when time is stopped.
MEMORY FUNCTION (Count Down or Up Timing)
When timing repetiti e inter als, the memory function will recall the last
programmed time. It allows the user to dedicate the timer to a frequently
timed test. The timer will return to the desired time period again and again.
Set a programmed time in either up or down timing. Press START. When the
alarm sounds, press any key to stop the tone from sounding. Press the
STOP key to stop the display from counting up. Press the MEMORY key to
display the original programmed time. Press the START key to begin a
memory time.
You may repeat this process as often as needed. Note: If RESET is pressed
when the time is stopped, it clears the display and the memory.
You may iew the time in the memory while the timer is running by holding
down the MEMORY key. When the MEMORY key is released, the display
returns to the running time.
TIMEOUT
The timer may be stopped during any running time by pressing the STOP
key. Timing may be resumed by pressing the START key.
STOPWATC TIMING
1. Press the MODE key until TMR appears on the display. If the timer is
running, press STOP to stop the timer. Press the RESET key to clear
the display to zero. Press the (▲▼) key until ▲ appears on the
display (▲ indicates count up timing).
2. Press the START key to start timing. The timer may be stopped by
pressing the STOP key and restarted by pressing the START key
(timeout function). When timing has been completed and the timer has
been stopped, press the RESET key to clear the display to zero.
TIME-OF-DAY CLOCK SETTING
1. Press the MODE key until CLK appears on the display. Press the
(▲▼) key and SET will appear on the display.
2. Press number keys 0 through 9 to set the time-of-day. Example: for
10:32 PM press 1,0,3,2. Press MEMORY for PM. Press (▲▼) to enter
the time and start the seconds counting.
TIME-OF-DAY ALARM SETTING
1. Press MODE Key until CLK appears on the display. Press RESET and
AL will appear on the display. Press the (▲▼) key and SET will
appear on the display.
2. Press number keys 0 through 9 to set the time-of-day alarm. Example:
to alarm at 3:21 PM press 3,2,1. Press the MEMORY key for PM. Press
(▲▼) to enter the alarm time. The “(((A” on the display indicates the
alarm is on and will sound at the alarm time. Press the RESET key to
return to the clock mode.
3. When the time-of-day alarm time is reached, a tone will sound for four
minutes and then turn off automatically to preser e battery life. To turn
the audible alarm off manually, press any key while the timer is in any
mode.
4. To turn the time-of-day alarm on or off, press the MODE key to enter
the CLK mode. Press START/STOP to pre ent the alarm from
sounding, “(((A” disappears from display. Press START/STOP to
acti ate the alarm, “(((A” appears on the display.
Note: When the time-of-day alarm is acti ated a tone will sound for four
seconds e ery hour on the hour. To stop the hourly tone the time-of-day
alarm must be turned off.
5. To re iew a time-of-day alarm time, place the timer in the clock mode
and press RESET once. Press the RESET key to return to the clock
mode.
ILLEGAL TIMES
Entering more than 59 minutes in the minutes’ digits or 59 seconds in the
seconds’ digits, or entering a number greater than 12 hours when setting the
time-of-day will prompt an alarm and an E (error message) on the display
when the START key is pressed. Press RESET to clear the display and enter
a legal time.
TRACEABLE
®
100
-
HOUR MINI
-
ALARM
TIMER/STOPWATCH
INSTRUCTIONS
BATTERY
An incorrect display or no display indicates that the battery should be replaced. Equi alent battery replacements are: RAYOVAC RW42, DURACELL 0357, and
EVEREADY 357.Insert the battery with the positi e side facing you.
Warranty, Service, or Recalibration
For warranty, ser ice, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E- ail sales@control3.co
www.control3.co
Control Co pany is ISO 9001 Quality-Certified by DNV and ISO 17025 accredited as a Calibration
Laboratory by A2LA.
Traceable
®
is a registered trademark of
Control Company
©2008 Control Company. 92-5021-00 Re . 2 040408

Other manuals for TRACEABLE

5

Other Control Company Timer manuals

Control Company TRACEABLE 1021 User manual

Control Company

Control Company TRACEABLE 1021 User manual

Popular Timer manuals by other brands

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

ENDA EM4401 Series manual

ENDA

ENDA EM4401 Series manual

NuTone CD60W quick start guide

NuTone

NuTone CD60W quick start guide

STI LT-1UL quick start guide

STI

STI LT-1UL quick start guide

Emos ESI2001 manual

Emos

Emos ESI2001 manual

TFA TRIPLE TIME manual

TFA

TFA TRIPLE TIME manual

Radio Shack 630-0892 Operation manual

Radio Shack

Radio Shack 630-0892 Operation manual

Eltako S2U12DBT-UC instructions

Eltako

Eltako S2U12DBT-UC instructions

axhess 2.440.007 manual

axhess

axhess 2.440.007 manual

Flash 31514 manual

Flash

Flash 31514 manual

Hunter 45030 Setup and operation manual

Hunter

Hunter 45030 Setup and operation manual

Slackers Ninja Timer quick guide

Slackers

Slackers Ninja Timer quick guide

BDH Elkay 550A-1 Instruction guide

BDH

BDH Elkay 550A-1 Instruction guide

NSi INDUSTRIES Tork RZ327 Programming instructions

NSi INDUSTRIES

NSi INDUSTRIES Tork RZ327 Programming instructions

Leviton VPT24 installation instructions

Leviton

Leviton VPT24 installation instructions

SBC KOP EX Series instructions

SBC

SBC KOP EX Series instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.