1
P85757A Copyright 2020 Cooper Wheelock Inc., dba Cooper Notication. All rights reserved.
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
GENERAL
The Wheelock Eluxa ELSP and ELSPST Series High-Fidelity Multi-Candela Speaker Strobes are designed for easy installation with
a pre-wire capable mounting plate. The Speaker Strobes with amber lens are UL Listed under Standard 1638 (Visual Signalling Ap-
pliance) for Private Mode Emergency General Utility Signaling. Amber lens strobe appliances also comply with the polar distribution
requirements in the UL Standard 1971 for Indoor Fire Protection Service and NFPA-72 for Mass Notication Systems.
The ELSP and ELSPST Series High-Fidelity Multi-Candela Speaker Strobes are designed for multiple power requirements with high
dBA output at each power tap. ELSP and ELSPST series speakers are UL rated to meet the NFPA 72 requirement for 520Hz signals in
sleeping areas when used in conjunction with Wheelock Safepath products (see SP40S manual for more details)
The design incorporates a high e󰀩ciency speaker for maximum output at minimum power across a frequency range of 300-8000Hz.
The Speaker Strobes can provide non-synchronized strobe operation when connected directly to a Fire Alarm Control Panel (FACP), or
provide synchronized strobe operation when used in conjunction with a Dual Sync Module (DSM), or Wheelock’s Power Supplies.
The Wheelock Eluxa Series meets NFPA 2016 20 millisecond light pulse duration code requirements. In addition, the Wheelock
Eluxa and LED3 product lines have been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories
that have been determined to be compatible with Wheelock model RSS Strobe based products including the RSS, CH, E, EH,
ET,ST,HS,MT,S8, SA, STH and Z Series. The maximum number of Eluxa devices per NAC is determined by dividing the maximum
current rating of the FACP NAC by the total current rating of one Eluxa device, with a maximum of 105 Eluxa (or LED3) devices per
NAC. Refer to FACP installation instructions for more detail. The Wheelock Eluxa Series and Exceder LED3 Series strobes may be
installed in the same notication zone and eld of view with any RSS Strobe based product.
WARNING: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. FAILURE TO COMPLY
WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICA-
TION, CANDELA SETTING, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,
WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS
CAUTION: Do not change factory applied nishes. “DO NOT PAINT”.
ATTENTION: Ne pas modiez les nitions appliquées en usine. “NE PAS PEINTURER”
Table 1: Specications
Agency ELSPST: UL1971, ULC-526-16. ELSPST-A: UL1638*, ULC-526-16
ELSP: UL1480, ULC-541-16
Environmental Indoor Use Only. 0ºC - 50ºC (+32ºF - 122ºF) 93% RH
NAC Characteristics Max. line resistance: 35Ω
Input Voltage
Audio: 25Vrms or 70.7Vrms
Strobe: DC or FWR, 24V Regulated, 16 to 33V
Settings Strobe: 15, 30, 75, 110, 135, 185cd (eld selectable)
Speaker: 1/8W, 1/4W, 1/2W, 1W, 2W, 5W
*UL1638 is an on axis rating where the following applies: eective candela rating per UL1971.
Table 2a: UL/ULC Listed Speaker Models and Ratings
Model Speaker
Voltage
Reverberant dBA at 10 Feet
Per UL 1480
Anechoic dBA at 10 Feet
Per ULC-S541-16
1/8 1/4 1/2 1 2 5 1/8 1/4 1/2 1 2 5
ELSP
25 75 79 82 85 87 --- 75 79 82 85 87 ---
70.7 75 79 82 85 --- 87 75 79 82 85 --- 87
ELSPST
25 75 79 82 85 87 --- 75 79 82 85 87 ---
70.7 75 79 82 85 --- 87 75 79 82 85 --- 87
Table 2b: ULC Directional Characteristics
-3dB +/- 80 degrees horizontal; +/- 80 degrees vertical
-6dB +/- 90 degrees horizontal; +/- 90 degrees vertical
Table 3: Strobe Current Draw (Amps) @ 24 volts
Strobe Candela Settings (cd)
Current 15cd 30cd 75cd 110cd 135cd 185cd
DC 0.022 0.030 0.060 0.086 0.125 0.185
FWR 0.036 0.050 0.092 0.142 0.196 0.274
NOTES:
1. Candela setting will determine the current draw of the product.
2. Strobes will produce 1 ash per second over the “Regulated Voltage” range.
3. Strobes are not designed to be used on coded systems in which the applied voltage is cycled on and o󰀨.
4. When calculating the total currents, use Table 3 to determine the highest value of “RMS Current” for an individual strobe (across
the expected operating voltage range of the strobe), then multiply these values by the total number of strobes; be sure to add
the currents for any other appliances, including audible signaling appliances, powered by the same source and include any
required safety factors.
5. Make sure that the total RMS current required by all appliances that are connected to the system’s primary and secondary
power sources, NAC Circuits , DSM Sync Modules or Cooper Wheelock Power Supplies do not exceed the power sources’ rated
capacity or the current ratings of any fuses on the circuits to which these appliances are wired. Refer to Sync Module instruction
sheets DSM (P83177) or Wheelock Power Supplies for additional information.
6. Check the minimum and maximum output of the power supply and standby battery and subtract the voltage drop from the circuit
wiring resistance to determine the applied voltage to the strobes.
7. Strobe appliance was tested to the regulated voltage limits of 16.0-33.0 Volts for 24 volt models using ltered DC or unltered
DC. Do not apply voltage outside of this range.
8. Strobe appliances are UL Listed as “Regulated”. They are intended to be used with Fire Alarm Control Panels (FACPs) whose
notication circuits are UL Listed as “Regulated”. Refer to the FACP instructions or the Wheelock Strobe Compatibility Data
Sheet (P85328) for special application and strobe synchronization compatibility.
WARNING: AMBER STROBES ARE NOT TO BE USED AS A VISUAL PUBLIC MODE ALARM NOTIFICATION APPLIANCE.
WARNING: OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS COULD RESULT IN LOSS OF POWER
AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY.
CAUTION: Always operate audio ampliers and speakers within their specied ratings. Excessive input may distort
sound quality and may damage audio equipment. Improper input voltage can damage speaker. If distortion is heard, check
for clipping of the audio signal voltage with an oscilloscope and reduce the amplier input level or gain level to eliminate
any clipping.
WARNING: WHEN INSTALLING STROBES IN AN OPEN OFFICE OR OTHER AREAS CONTAINING PARTITIONS OR OTHER
VIEWING OBSTRUCTIONS, SPECIAL ATTENTION SHOULD BE GIVEN TO THE LOCATION OF THE STROBES SO THAT
THEIR OPERATING EFFECT CAN BE SEEN BY ALL INTENDED VIEWERS, WITH THE INTESITY, NUMBER, AND ILLUMINA-
TION, REGARDLESS OF THE VIEWER’S ORIENTATION.
NOTE:The 110cd setting for the Clear Lens is Listed for use in sleeping or non-sleeping areas when installed in accordance with
appropriate NFPA Standards and the Authority Having Jurisdiction.
WARNING: A SMALL POSSIBILITY EXISTS THAT THE USE OF MULTIPLE STROBES WITHIN A PERSON’S FIELD OF
VIEW, UNDER CERTAIN CIRCUMSTANCES, MIGHT INDUCE A PHOTO-SENSITIVE RESPONSE IN PERSONS WITH EPILEPSY.
STROBE REFLECTIONS IN A GLASS OR MIRRORED SURFACE MIGHT ALSO INDUCE SUCH A RESPONSE. TO MINIMIZE
THIS POSSIBLE HAZARD, COOPER WHEELOCK STRONGLY RECOMMENDS THAT THE STROBES INSTALLED SHOULD
NOT PRESENT A COMPOSITE FLASH RATE IN THE FIELD OF VIEW WHICH EXCEEDS FIVE (5) HZ AT THE OPERAT-
ING VOLTAGE OF THE STROBES. COOPER WHEELOCK ALSO STRONGLY RECOMMENDS THAT THE INTENSITY AND
COMPOSITE FLASH RATE OF INSTALLED STROBES COMPLY WITH LEVELS ESTABLISHED BY APPLICABLE LAWS,
STANDARDS, REGULATIONS, CODES AND GUIDELINES.
NOTE: NFPA 72/ANSI 117.1 conforms to ADAAG Equivalent Facilitation Guidelines in using fewer, higher intensity strobes within the
same protected area.
INSTALLATION INSTRUCTIONS
WHEELOCK ELUXA HIGH FIDELITY SPEAKER
AND SPEAKER STROBE WITH PRE-WIRE/PRE-TEST
WALL MOUNT (CLEAR AND AMBER LENS)
2
P85757A
WIRING INFORMATION:
A blocking capacitor for DC supervision of audio lines by the FACP is factory wired in series with the speaker input. Supervision voltage
must not exceed 33 volts DC.
1. ELSPST Speaker Strobe models have terminals that accept #12 to #18 American Wire Gauge (AWG) wires at each screw terminal.
Strip leads 3/8 inches and connect to screw terminals. Do not fully back out terminal screws.
2. Break all in-out wire runs on supervised circuits to assure integrity of circuit supervision as shown in Figure 2. The polarity shown in
Figure 1 the wiring diagram is for operation of the appliances.
3. Using the slide switch shown in Figure 3, select voltage and wattage as shown in Table 4 below. Each letter corresponds to a position of
the switch located on the printed circuit board. The ELSP comes pre-set on setting F (70V @ 1/2 W).
4. Each doubling of rated Watts increases sound output by 3 dBA.
OR END-OF-LINE
TO NEXT SIGNAL
RESISTOR (EOLR)
FROM PRECEDING
APPLIANCE, FACP
OR SYNC MODULE
FROM PRECEDING
APPLIANCE
AUDIO
VISUAL
Figure 1: Speaker Strobe Wiring
Figure 2: Wire
Connection
A B C D E F G H
SPEAKER dB SELECTION SWITCH
SHOWN SELECTOR ON 'F' SETTING
Figure 3: Speaker Setting Switch
Shown on Factory Setting “F”
CANDELA WINDOW
SHOWN AT FACTORY
SETTING. (15 Cd)
dB SELECTION
CANDELA SETTING SLIDER
Figure 4: Candela and dBA Settings
0%
20%
40%
60%
80%
100%
120%
140%
160%
180%
200%
-100 -80 -60 -40 -20 0 20 40 60 80 100
% of Rating
Angle
Expected
Horizontal
Values
Expected
Vertical
Values
Figure 5: ELSPST amd ELSPST-A Expected Light Output
Table 4: Speaker Setting Chart
Position 25V 70V
A 2W ------
B 1W ------
C 1/2W ------
D 1/4W 5W
E 1/8W 1W
F ------ 1/2W
G ------ 1/4W
H ------ 1/8W
INSERT SCREW DRIVER INTO
SLOT, PUSH IN TO RELEASE
SNAP AND LIFT UP TO REMOVE
THE COVER
1
2
Figure 6: Grille Removal
BREAK OFF WHEN 3/4"
CONDUIT IS USED
(2)#10 WOOD SCREW
CONDUIT METAL STRAP
(2)MOUNTING TAB
SUFACE BACKBOX
Figure 7: Surface Backbox Box
NOTE: Surface backbox (ELSPKBB) shown in Figure 7, is compatible with wiremold and conduit. Mounting holes are for single-gang,
double-gang, and #10 wood screws for surface mounting. If metal conduit is installed onto top and bottom conduit entrances, then an
insulated grounding wire (18 AWG, supplied) must be connected between the top and bottom plate by using thread cutting screws (sup-
plied) to provide electrical continuity per UL 50.
CAUTION: The following gures show the maximum number of eld wires (conductors) that can enter the backbox used with each
mounting option. If these limits are exceeded, there may be insu󰀩cient space in the backbox to accommodate the eld wires and stresses
from the wires could damage the product.
IMPORTANT: Strobe device has only one mounting orientation. LED light element should be oriented toward the oor.
MOUNTING OPTIONS:
Figure A: Surface Mount with ELSPKBB
(2)#8-32 THREAD CUTTING SCREW
Figure B: Flush Mount - 4”SQ x 2 1/8” Back Box
(2)#8-32 THREAD CUTTING SCREW
4" SQUARE BACKBOX
Maximum Number of Conductors Maximum Number of Conductors
AWG#18 AWG#16 AWG#14 AWG#12 AWG#18 AWG#16 AWG#14 AWG#12
8 8 8 8 8 8 8 8
CAUTION: Check that the installed product will have su󰀩cient clearance and wiring room prior to installing backboxes and
conduit, especially if sheathed multiconductor cable or 3/4” conduit ttings are used.
Wiring method shall be in accordance with:
1) In the United States, the National Electrical Code, NFPA 70, and the National Fire Alarm and Signaling Code, NFPA 72.
2) In Canada, CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.
MOUNTING PROCEDURES:
1. Select a mounting option and install the backbox. ELSPKBB requires 5 1/8” spacing for surface mounting. Screws are provided.
Conduit entrances to the backbox should be selected to provide su󰀩cient wiring clearance for the installed product. Do not pass
additional wires (used for other than the signaling appliance) through the backbox. Such additional wires could result in insu󰀩cient
wiring space for the signaling appliance.
2. Install the Mounting Plate on the backbox with “TOP” facing up. Use 8-32 screws for 4” back-box or hi-lo screws for the ELSPKBB.
3. Pre-Wire: Connect eld wires to terminals on mounting plate (reference Figure 1 and 2). Ensure the speaker wiring is connected to
speaker terminals only, and strobe wiring is connected to strobe terminals only. Use care and proper techniques to position the eld
wires in the backbox so that they use minimum space and produce minimum stress on the product. This is especially important for
sti󰀨, heavy gauge wires and wires with thick insulation or sheathing. When terminating eld wires, do not use more lead length than
required. Excess lead length could result in insu󰀩cient wiring space for the signaling appliance.
4. Pre-Test: Mounting Plate contains a SHUNT between adjacent “+” terminals to facilittate testing before device is attached.
Note: Shunt will open permanently when device is installed on mounting plate.
5. Verify appliance settings are correct for your application. Selector switch locations are shown in Figure 4. Strobe settings are 15cd,
30cd, 75cd, 110cd, 135cd, 185cd. Speaker Setting Chart is shown in Table 4. Factory settings are (F) 70V, 1/2W and 15cd.
6. Place the ELUXA appliance over the mounting plate. Engage TOP hook on mounting plate, then secure with screw at the BOTTOM.
Use care to prevent speaker cone damage when driving the screw.
7. Align cover to the ELUXA appliance with strobe opening over LED lens. Then, snap the cover in place.
8. To remove the cover, insert a small at-bladed screwdriver into the bottom opening ½” as shown in Figure 6. Then pry o󰀨 beauty
cover with the screwdriver.
9. Accessories for ELUXA Speaker Strobes: ELSPKBB (Red: CN110754; White: CN110755).
NOTE: Final acceptance is subject to Authorities Having Jurisdiction.
If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in
accordance with NFPA 72, the appliance must be used with a re alarm control unit that can generate the temporal pattern signal. Refer
to manufacturer’s installation manual for details.
CAUTION: Do not over tighten mounting screws. Excessive torque can distort the base and may a󰀨ect operation. When
using power tools to screw down the mounting plate to the electrical backbox, ensure the torque is set to the lowest setting
available.
CAUTION: Check the installation instructions of the manufacturers of other equipment used in the system for any guide-
lines or restrictions on wiring and/or locating Notication Appliance Circuits (NAC) and notication appliances. Some system
communication circuits and/or audio circuits, for example, may require special precautions to assure electrical noise immunity
(e.g., audio crosstalk).
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
-commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a resi-
dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada.
Any material extrapolated from this document or from Cooper Wheelock manuals or other documents describing the product for use in
promotional or advertising claims, or for any other use,including description of the product’s application, operation, installation and testing
is used at the sole risk of the user and Cooper Wheelock will not have any liability for such use.
IN NO CASE WILL SELLER’S LIABILITY EXCEED THE PURCHASE PRICE PAID FOR A PRODUCT.
07/20

This manual suits for next models

8

Other Cooper Wheelock Speakers manuals

Cooper Wheelock Series SA-S70-24MCW-FR User manual

Cooper Wheelock

Cooper Wheelock Series SA-S70-24MCW-FR User manual

Cooper Wheelock ST-B4 User manual

Cooper Wheelock

Cooper Wheelock ST-B4 User manual

Cooper Wheelock STH-15S User manual

Cooper Wheelock

Cooper Wheelock STH-15S User manual

Cooper Wheelock STH-4M30WC User manual

Cooper Wheelock

Cooper Wheelock STH-4M30WC User manual

Cooper Wheelock STH-2R24MCCH(X) User manual

Cooper Wheelock

Cooper Wheelock STH-2R24MCCH(X) User manual

Cooper Wheelock STH-4R24MCCH-NR User manual

Cooper Wheelock

Cooper Wheelock STH-4R24MCCH-NR User manual

Cooper Wheelock SERIES S-24MCC User manual

Cooper Wheelock

Cooper Wheelock SERIES S-24MCC User manual

Cooper Wheelock STH-4MSR User manual

Cooper Wheelock

Cooper Wheelock STH-4MSR User manual

Cooper Wheelock ELUXA ELSP Series User manual

Cooper Wheelock

Cooper Wheelock ELUXA ELSP Series User manual

Cooper Wheelock S8-70/25 User manual

Cooper Wheelock

Cooper Wheelock S8-70/25 User manual

Cooper Wheelock STH-15S User manual

Cooper Wheelock

Cooper Wheelock STH-15S User manual

Cooper Wheelock DB4 Range User manual

Cooper Wheelock

Cooper Wheelock DB4 Range User manual

Popular Speakers manuals by other brands

Funktion-one F1201 user guide

Funktion-one

Funktion-one F1201 user guide

Bosch LBC 348300 Installation & user's instructions

Bosch

Bosch LBC 348300 Installation & user's instructions

Bose Acoustimass 500 manual

Bose

Bose Acoustimass 500 manual

Steren BAF-1295/USB user manual

Steren

Steren BAF-1295/USB user manual

Innova Wireless INNSTAR user manual

Innova

Innova Wireless INNSTAR user manual

YORTOT W08 user manual

YORTOT

YORTOT W08 user manual

Valcom V-1020C installation instructions

Valcom

Valcom V-1020C installation instructions

Pan Acoustics Mundorf AMT manual

Pan Acoustics

Pan Acoustics Mundorf AMT manual

Bogen NEAR OPS1 Installation and use manual

Bogen

Bogen NEAR OPS1 Installation and use manual

Numark Lightwave user guide

Numark

Numark Lightwave user guide

August VENUS user manual

August

August VENUS user manual

GoldenEar Technology Triton Seven owner's manual

GoldenEar Technology

GoldenEar Technology Triton Seven owner's manual

Samsin Innotec SBS-6600 Series user manual

Samsin Innotec

Samsin Innotec SBS-6600 Series user manual

Pure Acoustics RB-6C owner's manual

Pure Acoustics

Pure Acoustics RB-6C owner's manual

Genesis G6.1c Owners manual and set-up guide

Genesis

Genesis G6.1c Owners manual and set-up guide

B-I-C America FH8-W Installation and owner's manual

B-I-C America

B-I-C America FH8-W Installation and owner's manual

Sonus Faber serafino tradition owner's manual

Sonus Faber

Sonus Faber serafino tradition owner's manual

Bose DesignMax DM3P installation guide

Bose

Bose DesignMax DM3P installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.