Panel Programming (UDL)
(Note if you have completed SIA programming then skip to point 5)
From engineering menu press down arrow until you reach “UDL/Digi Options”, press
YES
Press down arrow until “Digi Options” is displayed, press YES
“Digi Options (* * * * * *)” is displayed, press NO twice
Display will now show “Digi is Enabled (E * * * * *)” press YES then menu
Press down arrow until you reach “UDL Options” press YES
Press down arrow until you reach “UDL Password” factory default is 1234, this is
optional if you wish to change then press NO and enter your password followed by
YES
Press down arrow until “UDL Options (* * * * * *)” is displayed, press NO
Press down arrow until “Manual Call-Back” is displayed then press NO again
Display will now show “Manual Call-Back (* M * * * *) press YES
Press down arrow until “Rings Required” is displayed, factory default is “005” press NO
and change to 001, press YES
Press menu followed by down arrow to “Setup Modules” press YES
Press down arrow until “Modem Speed” is displayed. Ensure this is set to 2400, if not
press NO until 2400 is displayed then press YES
Press menu followed by the down arrow until “Com Port Setup” is displayed, press YES
“Onboard Digicom (Com300 Module)” is now displayed, press NO then down arrow
until “Com2400 Module” is displayed, press YES
Unit is now setup for UDL
Things to consider on installation
Make a note of the panel’s Make, Model and Vers
E.G. Elite, 48, version x2
This information is critical when setting up a file in Wintex from where ever your UDL
connection is being made from