10.70 [271.8]
7.00 [177.8]
Dimensions are in Inches [mm]
13.5 [343]
11.8 [300]
10°
5.4 [137]
Dimensions are in Inches [Millimeter]
To mount a Clock Kit Wall Mount Adapter:
1. Use the TEMPLATE on this document to drill
four holes in the wall for the anchors and screws.
•PlacethefourPLASTIC RIBBED ANCHORS
into the holes you prepared.
• Screw the four #6 SHEET METAL SCREWS into
the four PLASTIC RIBBED ANCHORS.
2. Position the CLOCK KIT WALL MOUNT
ADAPTER over the four #6 SHEET METAL
SCREWS.
3. Move the CLOCK CONNECTOR COVER
PLATE. See the back of this placemat for details.
4. Connect Cables to the IP SPEAKER ASSEMBLY:
• Plug the ribbon cable from the clock into the IP
SPEAKER ASSEMBLY.
• Plug the Ethernet cable from the network into
the IP SPEAKER ASSEMBLY. The yellow light
verifies the network connection. See the back of
this placemat for details.
Note: You can route the Ethernet cable through
the back or through the slots at the top or bottom
of the WALL MOUNT ADAPTER.
5. Position the IP SPEAKER ASSEMBLY into the
CLOCK KIT WALL MOUNT ADAPTER so
that the IP SPEAKER ASSEMBLY screw holes
align with the mounting holes in the CLOCK
KIT WALL MOUNT ADAPTER.
•Usethree8-32 x 1 1/4” MOUNTING SCREWS
(from the Ceiling Speaker Drop Ceiling
Mounting Kit) to secure the IP SPEAKER
ASSEMBLY to the WALL MOUNT ADAPTER.
Step 5 Step 3
Step 2
Step 1
Step 4
From Network
to Speaker
From Clock
to Speaker
Dimensions
Features CyberData Part #011098 or #011099
PM LED
Ambient light detector
Mounting
Step 4
(3) 8-32 x 1 1/4” Mounting
Screws (from the Ceiling
Speaker Drop Ceiling
Mounting Kit)
Network cable routed through a wall
into the rear of the Clock Kit Wall
Mount Adapter.