3 Operacije
Operation manual
6
D2CNL024A1AA
Wall-mounted condensing boiler
3P469438-12N – 2020.07
3.3.5 Possible central heating operation modes
Mode Description
Boiler only The case that the system only
contains the boiler. No outdoor sensor
is connected. The central heating
water temperature setpoint is
displayed. The setpoint can be
adjusted with CH+ or CH- buttons.
The icon is shown on the screen
when the central heating operation
mode is enabled.
Boiler + outdoor sensor
(Weather compensation)
The case that outdoor sensor is
connected to the boiler. In this case,
the central heating water temperature
is regulated according to the outdoor
temperature. The virtual room
temperature setpoint is diplayed. The
virtual room temperature setpoint can
be adjusted with CH+ or CH- buttons.
Increasing or decreasing the setpoint
value reflects to the central heating
water temperature and the room
temperature, respectively.
The and icons are shown on the
screen when central heating operation
mode is enabled.
OBAVEŠTENJE
To enable weather compensation, the heating slope value
must be higher than "0" (see "User settings menu:
Parameters (short)"[47]).
3.3.6 About the central heating ECO mode
The central heating ECO mode provides more economic central
heating. Main purpose of the ECO mode is to operate the boiler at
the condensing temperature range so to increase the efficiency.
ECO mode can be activated at any central heating operation mode
explained above.
ECO mode can be enabled from the user settings menu (see "User
settings menu: Parameters (short)"[47]).
INFORMACIJA
ECO mode is only for central heating, it has no effect to
domestic water heating.
When central heating ECO mode is enabled, icon is shown on the
screen while the central heating operation mode is enabled.
OBAVEŠTENJE
In case of bad or inappropriate central heating circuit
design, which causes inadequate heat emission to the
living space, activating the ECO mode may cause capacity
shortage.
3.3.7 About the domestic hot water operation
This unit supplies domestic hot water by way of a plate heat
exchanger.
Domestic hot water operation is activated when water is being
tapped. Water flow rate must be at least 2.6l/min.
The icon is shown when domestic hot water operation is active.
INFORMACIJA
Domestic hot water operation mode must be enabled for
the boiler to be able to produce domestic hot water. (i.e.
summer mode or winter mode).
3.3.8 About the domestic hot water comfort
mode
In this mode, water in the primary circuit is kept warm to be able to
provide domestic hot water faster when there is demand.
Comfort mode can be enabled from the user settings menu (see
"User settings menu: Parameters (short)"[47]).
When the domestic hot water comfort mode is enabled, the icon is
shown on the screen.
3.3.9 About the boiler frost protection
Frost protection safety system: This function protects the unit and
heating installation from frost damages. This protection activates the
boiler pump when the water temperature drops below 15°C and it
activates the burner when the water temperature drops below 5°C
(factory setting). The unit keeps running until the temperature
reaches 15°C. To enable this function, the unit must be connected to
the power supply and its main gas valve must be open. Any damage
caused by frost is not covered by the warranty. Frost Protection is
enabled in all modes, including standby mode and full-off mode.
While frost protection is active, actual flow temperature is displayed.
UPOZORENJE
If the boiler is not connected to the power supply, frost
protection is not active. Consequently, the water may
freeze and cause cracks. The manufacturer is not
responsible for any damage that may occur this way.
OBAVEŠTENJE
When not using the boiler, we strongly recommend not to
cut off the electric supply to the boiler.
3.4 Error handling
When an error occurs, the normal behaviour of the user interface is
interrupted. However, be aware that not all errors have the same
effect on the user interface and the status indicator.
Error
type
Boiler operation User interface and status
indicator
Warning Continue The LCD screen stays active and
displays the error code.
Blocking Blocked, turns back
to operation if
cause disappears
The LCD screen stays active and
displays the error code.
Lockout Blocked and a
reset is required
The LCD screen stays active and
displays the error code. Also, the
icon starts blinking, indicating that a
reset is required.
In case of a warning or a blocking error, the user interface will leave
error mode and return to the home screen when the cause of the
error disappears.
In case of a lockout error, the boiler needs to be reset. Press the
"Reset" button to remove the error, if the cause of the error is gone.
If the cause of the error is still there, the user interface will enter
error mode again. When the error is solved, the user interface
returns to the home screen.
If you or press any button (except the "Reset" button) during an
error, the user interface will display the home screen. After the
timeout without any interaction, instead of darkening, the user
interface will enter error mode.