
Table of contents
Installer reference guide
3
ERGA04~08DAV3(A) + EHVZ04+08S18+23DA6V+9W7
Daikin Altherma 3 R F
4P618957-1 – 2020.03
6.4 Preparing water piping ................................................................................................................................................... 44
6.4.1 Water circuit requirements............................................................................................................................ 45
6.4.2 Formula to calculate the expansion vessel pre-pressure.............................................................................. 47
6.4.3 To check the water volume and flow rate ..................................................................................................... 47
6.4.4 Changing the pre-pressure of the expansion vessel...................................................................................... 49
6.4.5 To check the water volume: Examples .......................................................................................................... 50
6.5 Preparing electrical wiring .............................................................................................................................................. 50
6.5.1 About preparing electrical wiring................................................................................................................... 50
6.5.2 About preferential kWh rate power supply................................................................................................... 51
6.5.3 Overview of electrical connections except external actuators ..................................................................... 52
6.5.4 Overview of electrical connections for external and internal actuators....................................................... 52
7 Installation 55
7.1 Overview: Installation ..................................................................................................................................................... 55
7.2 Opening the units ........................................................................................................................................................... 55
7.2.1 About opening the units................................................................................................................................. 55
7.2.2 To open the outdoor unit............................................................................................................................... 55
7.2.3 To open the indoor unit ................................................................................................................................. 56
7.2.4 To lower the switch box on the indoor unit .................................................................................................. 58
7.3 Mounting the outdoor unit............................................................................................................................................. 59
7.3.1 About mounting the outdoor unit ................................................................................................................. 59
7.3.2 Precautions when mounting the outdoor unit.............................................................................................. 59
7.3.3 To provide the installation structure ............................................................................................................. 59
7.3.4 To install the outdoor unit ............................................................................................................................. 62
7.3.5 To provide drainage........................................................................................................................................ 63
7.3.6 To prevent the outdoor unit from falling over .............................................................................................. 64
7.4 Mounting the indoor unit ............................................................................................................................................... 65
7.4.1 About mounting the indoor unit.................................................................................................................... 65
7.4.2 Precautions when mounting the indoor unit................................................................................................. 65
7.4.3 To install the indoor unit ................................................................................................................................ 65
7.4.4 To connect the drain hose to the drain ......................................................................................................... 66
7.5 Connecting the refrigerant piping .................................................................................................................................. 67
7.5.1 About connecting the refrigerant piping ....................................................................................................... 67
7.5.2 Precautions when connecting the refrigerant piping.................................................................................... 67
7.5.3 Guidelines when connecting the refrigerant piping...................................................................................... 68
7.5.4 Pipe bending guidelines ................................................................................................................................. 69
7.5.5 To flare the pipe end ...................................................................................................................................... 69
7.5.6 To braze the pipe end..................................................................................................................................... 70
7.5.7 Using the stop valve and service port............................................................................................................ 70
7.5.8 To connect the refrigerant piping to the outdoor unit ................................................................................. 72
7.5.9 To connect the refrigerant piping to the indoor unit .................................................................................... 72
7.6 Checking the refrigerant piping...................................................................................................................................... 73
7.6.1 About checking the refrigerant piping........................................................................................................... 73
7.6.2 Precautions when checking the refrigerant piping........................................................................................ 73
7.6.3 To check for leaks ........................................................................................................................................... 74
7.6.4 To perform vacuum drying............................................................................................................................. 74
7.7 Charging refrigerant........................................................................................................................................................ 75
7.7.1 About charging refrigerant............................................................................................................................. 75
7.7.2 Precautions when charging refrigerant ......................................................................................................... 76
7.7.3 To determine the additional refrigerant amount.......................................................................................... 76
7.7.4 To determine the complete recharge amount.............................................................................................. 77
7.7.5 To charge additional refrigerant .................................................................................................................... 77
7.7.6 To fix the fluorinated greenhouse gases label............................................................................................... 77
7.8 Connecting water piping................................................................................................................................................. 78
7.8.1 About connecting the water piping ............................................................................................................... 78
7.8.2 Precautions when connecting the water piping............................................................................................ 78
7.8.3 To connect the water piping .......................................................................................................................... 78
7.8.4 To connect the recirculation piping ............................................................................................................... 80
7.8.5 To fill the water circuit ................................................................................................................................... 80
7.8.6 To fill the domestic hot water tank................................................................................................................ 81
7.8.7 To insulate the water piping .......................................................................................................................... 81
7.9 Connecting the electrical wiring..................................................................................................................................... 81
7.9.1 About connecting the electrical wiring.......................................................................................................... 81
7.9.2 About electrical compliance........................................................................................................................... 82
7.9.3 Precautions when connecting the electrical wiring....................................................................................... 82
7.9.4 Guidelines when connecting the electrical wiring......................................................................................... 82
7.9.5 Specifications of standard wiring components.............................................................................................. 83
7.9.6 To connect the electrical wiring to the outdoor unit .................................................................................... 83
7.9.7 To connect the electrical wiring to the indoor unit....................................................................................... 85
7.9.8 To connect the main power supply................................................................................................................ 86