3.2 “A1” Indoor Unit: PC Board Defect.........................................................183
3.3 “A3” Indoor Unit: Malfunction of Drain Level Control System (S1L) ......184
3.4 “A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................186
3.5 “A7” Indoor Unit: Malfunction of Swing Flap Motor (MA) .......................187
3.6 “A9” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (20E) ........................................................189
3.7 “AF” Indoor Unit: Drain Level above Limit..............................................191
3.8 “AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........192
3.9 “C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................193
3.10 “C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........194
3.11 “C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........195
3.12 “CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................196
3.13 “E1” Outdoor Unit: PC Board Defect ......................................................197
3.14 “E3” Outdoor Unit: Actuation of High Pressure Switch ..........................198
3.15 “E4” Outdoor Unit: Actuation of Low Pressure Sensor ..........................199
3.16 “E5”Compressor Motor Lock ................................................................200
3.17 “E6”STD Compressor Motor Overcurrent/Lock ....................................201
3.18 “E7”Malfunction of Outdoor Unit Fan Motor..........................................202
3.19 “E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................204
3.20 “F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................206
3.21 “F6”Refrigerant Overcharged ...............................................................207
3.22 “H7”Abnormal Outdoor Fan Motor Signal .............................................208
3.23 “H9” Outdoor Unit: Malfunction of Thermistor for
Outdoor Air (R1T).................................................................................209
3.24 “J2”Current Sensor Malfunction...........................................................210
3.25 “J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31~33T) .....................................................................................211
3.26 “J5” Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe ...212
3.27 “J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................213
3.28 “J8” Malfunction of Oil Equalizing Pipe Thermistor (R7T).....................214
3.29 “J9” Malfunction of Receiver Gas Pipe Thermistor (R5T).....................215
3.30 “JA” Outdoor Unit: Malfunction of Discharge Pipe Pressure Sensor.....216
3.31 “JC” Outdoor Unit: Malfunction of Suction Pipe Pressure Sensor .........217
3.32 “L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................218
3.33 “L5” Outdoor Unit: Inverter Compressor Abnormal ...............................219
3.34 “L8” Outdoor Unit: Inverter Current Abnormal.......................................220
3.35 “L9” Outdoor Unit: Inverter Start up Error..............................................221
3.36 “LC” Outdoor Unit: Malfunction of Transmission Between Inverter
and Control PC Board ..........................................................................222
3.37 “P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................224
3.38 “P4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise Sensor ....................................................................225
3.39 “UO” Low Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure......................................................226
3.40 “U1”Reverse Phase, Open Phase.........................................................227
3.41 “U2” Power Supply Insufficient or Instantaneous Failure ......................228
3.42 “U3”Check Operation not executed ......................................................230
3.43 “U4”Malfunction of Transmission Between Indoor Units ......................231