
Table of contents
Installer reference guide
3
ERRA08~12E + ELVZ12S18+23E
Daikin Altherma 3 R MT F
4P708478-1 – 2023.05
7.2.3 To remove the transportation stay................................................................................................................ 66
7.2.4 To attach the compressor cover piece .......................................................................................................... 67
7.2.5 To close the outdoor unit............................................................................................................................... 67
7.2.6 To open the indoor unit ................................................................................................................................. 68
7.2.7 To lower the switch box on the indoor unit .................................................................................................. 70
7.2.8 To close the indoor unit ................................................................................................................................. 71
7.3 Mounting the outdoor unit............................................................................................................................................. 71
7.3.1 About mounting the outdoor unit ................................................................................................................. 71
7.3.2 Precautions when mounting the outdoor unit.............................................................................................. 72
7.3.3 To provide the installation structure ............................................................................................................. 72
7.3.4 To install the outdoor unit ............................................................................................................................. 73
7.3.5 To provide drainage........................................................................................................................................ 74
7.3.6 To install the discharge grille.......................................................................................................................... 75
7.3.7 To remove the discharge grille, and put the grille in safety position............................................................ 77
7.4 Mounting the indoor unit ............................................................................................................................................... 79
7.4.1 About mounting the indoor unit.................................................................................................................... 79
7.4.2 Precautions when mounting the indoor unit................................................................................................. 79
7.4.3 To install the indoor unit ................................................................................................................................ 79
7.4.4 To connect the drain hose to the drain ......................................................................................................... 80
8 Piping installation 82
8.1 Preparing refrigerant piping ........................................................................................................................................... 82
8.1.1 Refrigerant piping requirements.................................................................................................................... 82
8.1.2 Refrigerant piping insulation.......................................................................................................................... 83
8.2 Connecting the refrigerant piping .................................................................................................................................. 83
8.2.1 About connecting the refrigerant piping ....................................................................................................... 84
8.2.2 Precautions when connecting the refrigerant piping.................................................................................... 84
8.2.3 Guidelines when connecting the refrigerant piping...................................................................................... 85
8.2.4 Pipe bending guidelines ................................................................................................................................. 85
8.2.5 To flare the pipe end ...................................................................................................................................... 86
8.2.6 To braze the pipe end..................................................................................................................................... 86
8.2.7 Using the stop valve and service port............................................................................................................ 87
8.2.8 To connect the refrigerant piping to the outdoor unit ................................................................................. 88
8.2.9 To connect the refrigerant piping to the indoor unit .................................................................................... 90
8.3 Checking the refrigerant piping...................................................................................................................................... 90
8.3.1 About checking the refrigerant piping........................................................................................................... 90
8.3.2 Precautions when checking the refrigerant piping........................................................................................ 91
8.3.3 Checking refrigerant piping: Setup ................................................................................................................ 91
8.3.4 To check for leaks ........................................................................................................................................... 92
8.3.5 To perform vacuum drying............................................................................................................................. 92
8.4 Charging refrigerant........................................................................................................................................................ 93
8.4.1 About charging refrigerant............................................................................................................................. 93
8.4.2 Precautions when charging refrigerant ......................................................................................................... 95
8.4.3 Charging additional refrigerant...................................................................................................................... 95
8.4.4 Completely recharging refrigerant................................................................................................................. 96
8.4.5 To fix the fluorinated greenhouse gases label............................................................................................... 97
8.5 Preparing water piping ................................................................................................................................................... 97
8.5.1 Water circuit requirements............................................................................................................................ 97
8.5.2 Formula to calculate the expansion vessel pre-pressure.............................................................................. 100
8.5.3 To check the water volume and flow rate ..................................................................................................... 100
8.5.4 Changing the pre-pressure of the expansion vessel...................................................................................... 103
8.5.5 To check the water volume: Examples .......................................................................................................... 103
8.6 Connecting water piping................................................................................................................................................. 104
8.6.1 About connecting the water piping ............................................................................................................... 104
8.6.2 Precautions when connecting the water piping............................................................................................ 104
8.6.3 To connect the water piping .......................................................................................................................... 104
8.6.4 To connect the recirculation piping ............................................................................................................... 107
8.6.5 To fill the water circuit ................................................................................................................................... 107
8.6.6 To fill the domestic hot water tank................................................................................................................ 107
8.6.7 To insulate the water piping .......................................................................................................................... 107
9 Electrical installation 108
9.1 About connecting the electrical wiring .......................................................................................................................... 108
9.1.1 Precautions when connecting the electrical wiring....................................................................................... 109
9.1.2 Guidelines when connecting the electrical wiring......................................................................................... 110
9.1.3 About electrical compliance........................................................................................................................... 111
9.1.4 About preferential kWh rate power supply................................................................................................... 111
9.1.5 Overview of electrical connections except external actuators ..................................................................... 112
9.2 Connections to the outdoor unit.................................................................................................................................... 113
9.2.1 Specifications of standard wiring components.............................................................................................. 113