Table of contents
Installation and operation manual
3
RYMA5+RXYA8~20A7Y1B
VRV 5 heat pump
4P739915-1 – 2023.12
Table of contents
1 About this document 4
2 Specific installer safety instructions 4
2.1 Instructions for equipment using R32 refrigerant ...................... 7
For the user 7
3 User safety instructions 7
3.1 General...................................................................................... 7
3.2 Instructions for safe operation ................................................... 8
4 About the system 10
4.1 System layout............................................................................ 10
5 User interface 11
6 Operation 11
6.1 Operation range ........................................................................ 11
6.2 Operating the system ................................................................ 11
6.2.1 About operating the system ........................................ 11
6.2.2 About cooling, heating, fan only, and automatic
operation ..................................................................... 11
6.2.3 About the heating operation........................................ 11
6.2.4 To operate the system (WITHOUT cool/heat
changeover remote control switch) ............................. 12
6.2.5 To operate the system (WITH cool/heat changeover
remote control switch)................................................. 12
6.3 Using the dry program ............................................................... 12
6.3.1 About the dry program ................................................ 12
6.3.2 To use the dry program (WITHOUT cool/heat
changeover remote control switch) ............................. 12
6.3.3 To use the dry program (WITH cool/heat changeover
remote control switch)................................................. 12
6.4 Adjusting the air flow direction................................................... 13
6.4.1 About the air flow flap ................................................. 13
6.5 Setting the master user interface .............................................. 13
6.5.1 About setting the master user interface ...................... 13
6.5.2 To designate the master user interface ...................... 13
7 Maintenance and service 14
7.1 Precautions for maintenance and service ................................. 14
7.2 About the refrigerant.................................................................. 14
7.3 After-sales service ..................................................................... 14
7.3.1 Recommended maintenance and inspection.............. 14
8 Troubleshooting 14
8.1 Error codes: Overview ............................................................... 15
8.2 Symptoms that are NOT system malfunctions .......................... 16
8.2.1 Symptom: The system does not operate .................... 16
8.2.2 Symptom: Cool/Heat cannot be changed over ........... 16
8.2.3 Symptom: Fan operation is possible, but cooling and
heating do not work..................................................... 16
8.2.4 Symptom: The fan speed does not correspond to the
setting ......................................................................... 16
8.2.5 Symptom: The fan direction does not correspond to
the setting ................................................................... 16
8.2.6 Symptom: White mist comes out of a unit (Indoor
unit) ............................................................................. 16
8.2.7 Symptom: White mist comes out of a unit (Indoor
unit, outdoor unit) ........................................................ 16
8.2.8 Symptom: The user interface reads "U4" or "U5" and
stops, but then restarts after a few minutes ................ 16
8.2.9 Symptom: Noise of air conditioners (Indoor unit)........ 16
8.2.10 Symptom: Noise of air conditioners (Indoor unit,
outdoor unit)................................................................ 16
8.2.11 Symptom: Noise of air conditioners (Outdoor unit) ..... 17
8.2.12 Symptom: Dust comes out of the unit ......................... 17
8.2.13 Symptom: The units can give off odours..................... 17
8.2.14 Symptom: The outdoor unit fan does not spin ............. 17
8.2.15 Symptom: The display shows "88"............................... 17
8.2.16 Symptom: The compressor in the outdoor unit does
not stop after a short heating operation ....................... 17
8.2.17 Symptom: The inside of an outdoor unit is warm
even when the unit has stopped .................................. 17
8.2.18 Symptom: Hot air can be felt when the indoor unit is
stopped ........................................................................ 17
9 Relocation 17
10 Disposal 17
For the installer 17
11 About the box 17
11.1 To remove the accessories from the outdoor unit ...................... 17
11.2 Accessory pipes: Diameters ....................................................... 17
11.3 To remove the transportation stay (only for 5~12 HP) ............... 18
12 About the units and options 18
12.1 About the outdoor unit ................................................................ 18
12.2 System layout ............................................................................. 18
13 Special requirements for R32 units 19
13.1 Installation space requirements.................................................. 19
13.2 System layout requirements ....................................................... 19
13.3 To determine the required safety measures............................... 21
13.3.1 Overview: flowchart...................................................... 22
13.4 Safety measures ........................................................................ 22
13.4.1 No safety measure....................................................... 22
13.4.2 Alarm............................................................................ 22
13.4.3 Natural ventilation ........................................................ 23
13.4.4 Shut-off valves ............................................................. 24
13.4.5 Overview: flowchart...................................................... 26
13.5 Combinations of safety measures .............................................. 27
14 Unit installation 27
14.1 Preparing the installation site ..................................................... 27
14.1.1 Installation site requirements of the outdoor unit ......... 27
14.1.2 Additional installation site requirements of the
outdoor unit in cold climates ........................................ 27
14.2 Opening the unit ......................................................................... 28
14.2.1 To open the outdoor unit.............................................. 28
14.2.2 To open the switch box of the outdoor unit .................. 28
14.3 Mounting the outdoor unit........................................................... 28
14.3.1 To provide the installation structure ............................. 28
14.3.2 To install the outdoor unit............................................. 29
15 Piping installation 29
15.1 Preparing refrigerant piping ........................................................ 29
15.1.1 Refrigerant piping requirements................................... 29
15.1.2 Refrigerant piping material........................................... 29
15.1.3 To select the piping size .............................................. 29
15.1.4 To select refrigerant branch kits................................... 30
15.1.5 Installation limitations................................................... 31
15.1.6 Multiple outdoor units: Possible layouts....................... 31
15.2 Connecting the refrigerant piping ............................................... 32
15.2.1 Using the stop valve and service port .......................... 32
15.2.2 To route the refrigerant piping...................................... 32
15.2.3 To protect against contamination................................. 33
15.2.4 To remove the pinched pipes....................................... 33
15.2.5 To connect the refrigerant piping to the outdoor unit ... 33
15.2.6 To connect the multi connection piping kit ................... 33
15.2.7 To connect the refrigerant branching kit ...................... 34
15.3 Checking the refrigerant piping .................................................. 34
15.3.1 About checking the refrigerant piping .......................... 34
15.3.2 Checking refrigerant piping: General guidelines .......... 34
15.3.3 Checking refrigerant piping: Setup............................... 35
15.3.4 To perform a leak test .................................................. 35
15.3.5 To perform vacuum drying ........................................... 35