EKHBH/X016AB
Indoor unit for hot water heat pump system and options Operation manual
6
Selecting powerful domestic water heating operation
1Press vfor 5 seconds to activate powerful domestic water
heating operation.
Icons wand mstart flashing.
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (s)
1Use the sbutton to activate quiet mode operation (s).
Icon sappears on the display.
If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 10), the sbutton will not be operable.
Selecting weather dependent set point operation (only in
heating mode)
1Press the ba button to select weather dependent set point
operation.
Icon aappears on the display as well as the shift value. The
shift value is not shown in case it is 0.
2Use the bi and bj buttons to set the shift value.
Range for the shift value: –5°C to +5°C
Displaying actual temperatures
1Push the ba button for 5 seconds.
The bicon and the outgoing water temperature are displayed.
The icons land =are flashing.
2Use the pi and pj buttons to display:
• The outdoor temperature (uicon is flashing).
•The domestic hot water tank temperature (wicon is
flashing).
• The outgoing water temperature (=are flashing).
If no button is pressed for 5 seconds, the controller leaves the
display mode.
Schedule timer operation
In schedule timer operation, the installation is controlled by the
schedule timer.The actions programmed in the schedule timer will be
executed automatically.
The schedule timer always follows the last command until a new
command is given.This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to "Manual operation" on page 5). The schedule timer will regain
control over the installation as soon as the next programmed
command of the schedule timer occurs.
The schedule timer is enabled (picon displayed) or disabled (picon
not displayed), by pressing the pr button.
To set up the SCHEDULE TIMER refer to chapter "Programming and
consulting the schedule timer" on page 7.
What can the schedule timer do?
The schedule timer allows the programming of:
1Space heating and space cooling (refer to "Programming space
cooling or space heating" on page 8)
Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Five
actions per weekday can be programmed, totalling 35 actions.
2Quiet mode (refer to "Programming quiet mode, booster heating
or domestic water heating" on page 9)
Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.
3Booster heating (refer to "Programming quiet mode, booster
heating or domestic water heating" on page 9)
Allow or disallow booster heating at a scheduled time. Five
actions can be programmed per mode. These actions are
repeated daily.
4Domestic water heating (refer to "Programming quiet mode,
booster heating or domestic water heating" on page 9)
Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.
NOTE Remark that pushing the ybutton has no influence
on the domestic water heating. Domestic water
heating is only switched on or off by means of the v
button.
NOTE ■Only use the pr button to enable or disable the
schedule timer. The schedule timer overrules the
ybutton. The ybutton only overrules the
schedule timer until the next programmed action.
■If the auto restart function is disabled, the
schedule timer will not be activated when power
returns to the unit after a power supply failure.
Press the pr button to enable the schedule timer
again.
■When power returns after a power supply failure,
the auto restart function reapplies the user
interface settings at the time of the power supply
failure.
It is therefore recommended to leave the auto
restart function enabled.
■The programmed schedule is time driven.Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to "Setting the clock" on page 4.
■Manually adjust the clock for summertime and
wintertime. Refer to "Setting the clock" on page 4.
■A power failure exceeding 1 hour will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to "Setting the clock" on page 4 to adjust the clock
and the day of the week.
■The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.
NOTE When the unit is connected to an external room
thermostat, the schedule timer for space cooling and
space heating is overruled by the external room
thermostat.
■The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.
■When the schedule timer switches space heating or
space cooling x, the controller will also be
switched off. Note that this has no influence on
domestic water heating.