Si39-502A
Table of Contents iii
3.9 “C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................162
3.10 “C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........163
3.11 “C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........164
3.12 “CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................165
3.13 “E1” Outdoor Unit: PC Board Defect ......................................................166
3.14 “E3” Outdoor Unit: Actuation of High Pressure Switch ..........................167
3.15 “E4” Outdoor Unit: Actuation of Low Pressure Sensor ..........................168
3.16 “E5” Outdoor Unit: Compressor Motor Lock ..........................................169
3.17 “E6” Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............170
3.18 “E7” Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................172
3.19 “E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................174
3.20 “F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................176
3.21 “F6” Outdoor Unit: Refrigerant Overcharged.........................................177
3.22 “H7” Outdoor Unit: Abnormal Outdoor Fan Motor Signal.......................178
3.23 “H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....179
3.24 “J2” Outdoor Unit: Current Sensor Malfunction ....................................180
3.25 “J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31 or 32T) ..................................................................................181
3.26 “J5” Outdoor Unit: Malfunction of Thermistor (R2T) for
Suction Pipe .........................................................................................182
3.27 “J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger Deicer...................................................183
3.28 “J7” Outdoor Unit: Malfunction of
Receiver Outlet Liquid Pipe Thermistor (R6T) .....................................184
3.29 “J9” Outdoor Unit: Malfunction of
Subcooling Heat Exchanger Gas Pipe Thermistor (R5T).....................185
3.30 “JA” Outdoor Unit: Malfunction of High Pressure Sensor......................186
3.31 “JC” Outdoor Unit: Malfunction of Low Pressure Sensor.......................187
3.32 “L4” Outdoor Unit: Malfunction of
Inverter Radiating Fin Temperature Rise .............................................188
3.33 “L5” Outdoor Unit: Inverter Compressor Abnormal ...............................189
3.34 “L8” Outdoor Unit: Inverter Current Abnormal.......................................190
3.35 “L9” Outdoor Unit: Inverter Start up Error..............................................191
3.36 “LC” Outdoor Unit: Malfunction of Transmission Between Inverter and
Control PC Board .................................................................................192
3.37 “P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................194
3.38 “P4” Outdoor Unit: Malfunction of
Inverter Radiating Fin Temperature Rise Sensor.................................195
3.39 “UO” Outdoor Unit: Low Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure......................................................196
3.40 “U1”Reverse Phase, Open Phase.........................................................197
3.41 “U2” Outdoor Unit: Power Supply Insufficient or
Instantaneous Failure...........................................................................198
3.42 “U3” Outdoor Unit: Check Operation not executed................................200
3.43 “U4”Malfunction of Transmission Between Indoor Units ......................201
3.44 “U5” Indoor Unit: Malfunction of Transmission Between
Remote Controller and Indoor Unit.......................................................203
3.45 “U7” Indoor Unit: Malfunction of Transmission Between
Outdoor Units .......................................................................................204