Dametric AB CEC-DM1 CAN-Ethernet-Converter
CEC-DM1 EN.docx June 2, 2008 Page 2 (3)
Table of contents
1GENERAL ...................................................................................................................................................2
2TECHNICAL SPECIFICATION...................................................................................................................2
3CONNECTION DIAGRAM ..........................................................................................................................2
4TROUBLESHOOTING................................................................................................................................3
5CONTACT ...................................................................................................................................................3
1 General
The CEC-DM1 is a converter module between the CAN bus and the Ethernet network.
It is used in the GMS measuring system for data exchange between the RMS/GMS units and the control
software in a Panel PC. The IP-based protocol uses the UDP transport layer for data exchange.
Each unit has a unique MAC-address and the configurable IP-address. The software in the Panel PC is set up
to exchange data to a specified IP-address.
The unit is powered with 24Vdc.
2 Technical Specification
Metso part no: VAL0219209
Supply voltage: 24 VDC, ± 10 %.
Power consumption: Nominal 0.1A, Max. 0.2A.
CAN: Up to 1Mbit baudrate, 4-pole jackable screw connector.
Ethernet; IP-based, UDP-protocol, RJ45 connector.
Module size: Height=110 mm, Width=23 mm, Depth=115 mm.
Closure: Polycarbonate (30%GV), DIN-rail mounting.
Connections: Plug-in screw connectors, max 2.5mm2 cable areas.
3 Connection Diagram
K1 +24VDC
K1/1 +24VDC The power supply (internally connected to K1/2)
K1/2 +24VDC The power supply (internally connected to K1/1)
K1/3 0VDC The power ground (internally connected to K1/4)
K1/4 0VDC The power ground (internally connected to K1/3)
K2 CAN
K2/1 CAN-H CAN-interface H-signal (use twisted pair cable for CAN-H and CAN-L)
K2/2 CAN-L CAN-interface L-signal
K2/3 CAN-R CAN-interface, connect to K2/2 for 120Ωtermination
K2/4 0VDC The power ground (internally connected to K1/2 and K1/3)
K3 Ethernet
K3 Ethernet RJ-45 connector