Dantel 46032-16 User manual

CAUTION
•Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.
•Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).
•Keep circuit boards in their antistatic bags when they are not in use.
•Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.
•For more complete information on electrostatic discharge safety
precautions, refer to BellcoreTM Technical Reference # TR-NWT-000870.
Copyright 1999 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered
Printed in the U.S.A.
INSTALLATION & OPERATION MANUAL
46032-16-0199<90-00149>
46032-16
RELAY MODULE
About this Practice:
This practice has been reissued to:
• Meet ISO 9001 requirements.
Issue date: January 1999
Reissued Practices: Updated and
new content can be identified by a
banner in the outside margin.
UPDATED
Table of Contents
Ordering Information ........................................................................... 2
General Description.............................................................................. 2
Circuit Description ............................................................................... 2
Installation............................................................................................ 4
Operation .............................................................................................. 5
Technical Specifications ....................................................................... 5
Warranty ............................................................................................... 6
46032-16
Relay
Module
B11-46032-16 REV__
CKT 1
CKT 3
CKT 5
CKT 7
CKT 9
CKT 11
CKT 13
CKT 15
CKT 2
CKT 4
CKT 6
CKT 8
CKT 10
CKT 12
CKT 14
CKT 16

PAGE 2 46032-16-0199 <90-00149>
ORDERING INFORMATION
NOTE: This section lists the different options available for this product. To order any of the avail-
able options, contact Dantel Inside Sales through our toll-free number, 1-800-432-6835.
OPTION NUMBER FEATURES
B11-46032-16 Relay Module
GENERAL DESCRIPTION
This practice decribes the 46032-16 Relay module and sup-
ports installation and maintenance to the change-out level.
The 46032-16 Relay Module uses 16 Form-A (normally open)
relays to control external switching operations. Each relay is
operated by the presence of a ground.
The front panel provides 16 LED indicators to visually monitor
the internal relay activity.
This module operates on -21 to -56 VDC input power.
CIRCUIT DESCRIPTION
The 46032-16 Relay Module functional schematic is shown in
Fig. 1. Refer to Table A for the individual relay pin-outs.
Relays K1 through K16 have Form-A (normally open) contacts
which provide controlled switching for external applications.
Relay activity is monitored separately by 16 LEDs on the front
panel which light when the corresponding circuit is energized.
Each circuit provides a constant current source for the relay
through the resistor, zener diode, and transistor over the DC
voltage range of -21 to -56 VDC.

46032-16-0199<90-00149> PAGE 3
A
C
B
-Batt
Relay
Coil Contact
Contact
Front Panel LED
NOTE: Circuit shown is typical for all circuits.
FIG. 1 - FUNCTIONAL SCHEMATIC, 46032-16 RELAY MODULE
TABLE A - PC PIN NUMBER, 46032-16 RELAY MODULE
RELAY NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
-Battery
Ground
RELAY COIL C
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
35
17
CONTACT A
1
3
5
7
9
11
13
15
19
21
23
25
27
29
31
33
CONTACT B
2
4
6
8
10
12
14
16
20
22
24
26
28
30
32
34
CIRCUIT DESCRIPTION

PAGE 4 46032-16-0199 <90-00149>
INSTALLATION
Install the module in the proper slot in the shelf. The shelf is
normally pre-wired at the factory. If necessary, refer to Figs. 1
and 2 and Table A for edge connector pin designations.
FIG. 2 - EDGE CONNECTOR PIN DESIGNATION, 46032-16
56 55
54 53
52 51
50 49
48 47
46 45
44 43
42 41
40 39
38 37
36 35
34 33
32 31
30 29
28 27
26 25
24 23
22 21
20 19
18 17
16 15
14 13
12 11
10 9
87
65
43
21
CIRCUIT SIDE
OF PC BOARD
COMPONENT SIDE
OF PC BOARD
K15K16
K13K14
K11K12
K9K10
K7K8
K5K6
K3K4
K1K2
-Battery
K16AK16B
K15AK15B
K14AK14B
K13AK13B
K12AK12B
K11AK11B
K10AK10B
K9AK9B
+Ground
K8AK8B
K7AK7B
K6AK6B
K5AK5B
K4AK4B
K3AK3B
K2AK2B
K1AK1B
Operating
Inputs
All relay
outputs are
normally-open

46032-16-0199<90-00149> PAGE 5
OPERATION
The relays operate on presence of a ground signal. There is no
latching capability. The relay contacts open when that
ground is removed. The individual LED should light on the front
panel as power is applied to each relay. This, however, does not
verify correct relay contact operation — only that ground is
applied to that individual relay coil.
TECHNICAL SPECIFICATIONS
DESCRIPTION
Input Voltage Range
Current Requirements
No relays Operating
One Relay Enabled
All Relays Enabled
Heat Dissipation
One Relay Enabled
All Relays Enabled
Current per Input to Operate
Resistance per Control Lead
Relay Contacts
Current Rating
Resistance
Operating Temperature
Physical Dimensions
Weight
DESCRIPTION
-21 to -56 VDC
@ -21VDC @ -24 VDC @ -48 VDC @ -56 VDC
0.0 mA 0.0 mA 0.0 mA 0.0 mA
6.7 mA 7.0 mA 8.6 mA 9.0 mA
106.0 mA 112.0 mA 140.0 mA 148.0 mA
@ -21VDC @ -24 VDC @ -48 VDC @ -56 VDC
0.48 Btu/Hr 0.58 Btu/Hr 1.41 Btu/Hr 1.72 Btu/Hr
7.68 Btu/Hr 9.28 Btu/Hr 22.56 Btu/Hr 27.52 Btu/Hr
6.0 mA
5.0K @ 24VDC; 1.5K @ 48VDC
1 Amp @ 30 VDC
0.1 Ohm
0° to 55° C.
1.4" x 6.0" x 5.6"
7.5 Ounces

PAGE 6
6 PAGES 46032-16-0199<90-00149>
LIMITED WARRANTY
The Seller warrants that the standard hardware products sold will be free from defects in material and work-
manship and perform to the Seller’s applicable published specifications for a period of 18 months for hardware,
and 3 months for software, from the date of the original invoice. The liability of the Seller hereunder shall be
limited to replacing or repairing, at its option, any defective products which are returned F.O.B. to the Seller’s
plant, (or, at the Seller’s option, refunding the purchase price of such products). In no case are products to be
returned without first obtaining permission and a customer return authorization number from the Seller. In
no event shall the Seller be liable for any consequential or incidental damages.
Equipment or parts which have been subject to abuse, misuse, accident, alteration, neglect, unauthorized
repair or installation are not covered by warranty. The Seller shall make the final determination as to the
existence and cause of any alleged defect. No warranty is made with respect to custom equipment or products
produced to the Buyer’s specifications except as specifically stated in writing by the Seller in the contract for
such custom equipment.
This warranty is the only warranty made by the Seller with respect to the goods delivered hereunder, and may
be modified or amended only by a written instrument signed by a duly authorized officer of the Seller and
accepted by the Buyer.
Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the
respective manufacturer. THE SELLER MAKES NO OTHER WARRANTY OF ANY KIND WHATSOEVER,
EXPRESSED OR IMPLIED; AND ALL IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PUR-
POSE WHICH EXCEEDS THE AFORESAID OBLIGATIONS IS HEREBY DISCLAIMED BY THE SELLER.
INCASE OF DIFFICULTY
If you experience difficulty with this equipment, check the following, as appropriate:
1. Switch settings
2. Signal levels
3. Software configuration
4. Connections between Dantel’s equipment and your equipment.
If there is still a problem, substitute equipment that is known to be good. For additional assistance, call
Dantel’s Technical Field Service Department weekdays, 6 A.M. to 5 P.M. pacific time:
1-800-4DANTEL(1-800-432-6835).
If a thorough checkout shows a piece of equipment has malfunctioned, you may return it to the factory. For
repairs and emergency replacements, obtain a Return Material Authorization (RMA) number from the Cus-
tomer Service Representative at 1-800-4DANTEL (1-800-432-6835).
To ensure expedient processing of your order, provide a purchase order number and shipping and billing
information when requesting an RMA number. Also, when the units are returned to Dantel, include a descrip-
tion of the failure symptoms for each unit returned. Send defective equipment to:
Dantel, Inc. • 2991 North Argyle Avenue • Fresno, California 93727-1388
P.O. Box 55013 • Fresno, CA 93747-5013 Phone (559) 292-1111 Fax (559) 292-9355 http://www.dantel.com