Datalogic SG-M User manual

SG-M
INSTRUCTION MANUAL
System is compatible with all Datalogic SG safety light curtains with muting function feature.
For correct use and safety prescriptions refer to the user manual of Datalogic safety light curtains where
muting kit is installed.
With modular muting systems it is possible to arrange multiple configurations.
MODEL DESCRIPTION ORDER NUMBER
SG-ML-S8-L Kit for L Muting, left side: 2 sensors S8-PR-3-B01-PP with a 0.7m
cable with M12 connector; 2 reflectors; 1 active arm; 1 passive
arm; 2 cable-lockers 95ASE2600
SG-ML-S8-R Kit for L Muting, right side: 2 sensors S8-PR-3-B01-PP with a
0.7m cable with M12 connector; 2 reflectors; 1 active arm; 1
passive arm; 2 cable-lockers 95ASE2370
SG-ML-S8-200-L Kit for L Muting, left side: 2 sensors S8-PR-3-B01-PP with a 2m
cable with M12 connector; 2 reflectors; 1 active arm; 1 passive
arm; 2 cable-lockers 95ASE2590
SG-ML-S8-200-R Kit for L Muting, right side: 2 sensors S8-PR-3-B01-PP with a 2m
cable with M12 connector; 2 reflectors; 1 active arm; 1 passive
arm; 2 cable-lockers 95ASE2340
SG-ML-S100-L Kit for L Muting, left side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2x 700mm cables with M12 connectors 95ASE2620
SG-ML-S100-R Kit for L Muting, right side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2x 700mm cables with M12 connectors 95ASE2430
SG-ML-S100-200-L Kit for L Muting, left side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2 x 2000mm cables with M12 connectors 95ASE2610
SG-ML-S100-200-R Kit for L Muting, right side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2 x 2000mm cables with M12 connectors 95ASE2400
MODEL DESCRIPTION ORDER NUMBER
SG-MT-S8 Kit for T Muting: 4 sensors S8-PR-3-B01-PP with a 0.7m cable
with M12 connector; 4 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2380
SG-MT-S8-200 Kit for T Muting: 4 sensors S8-PR-3-B01-PP with a 2m cable with
M12 connector; 4 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2350
SG-MT-S100 Kit for T Muting: 4 sensors S100-PR-5-B10-PK;
4 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
4 x 700mm cables with M12 connectors 95ASE2440
SG-MT-S100-200 Kit for T Muting: 4 sensors S100-PR-5-B10-PK;
4 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
4 x 2000mm cables with M12 connectors 95ASE2410
MODEL DESCRIPTION ORDER NUMBER
SG-MX-S8 Kit for X Muting; 2 sensors S8-PR-3-B01-PP with a 0.7m cable
with M12 connector; 2 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2390
SG-MX-S8-200 Kit for X Muting; 2 sensors S8-PR-3-B01-PP with 2m cable with
M12 connector; 2 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2360
SG-MX-S100 Kit for X Muting; 2 sensors S100-PR-5-B10-PK;
2 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
700mm pigtail cables with M12 connectors 95ASE2450
SG-MX-S100-200 Kit for X Muting; 2 sensors S100-PR-5-B10-PK;
2 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
2000mm pigtail cables with M12 connectors 95ASE2420
MOUNTING
Put the arm slider (1) into the column slot (2).
Fix the arm (3) in the desired position by screws (4), 1 Nm recommended tightening torque.
Rotate sensors/reflectors support (5) in the desired position ; if necessary, translate support removing
and spacing cable-locker (6) and fix by screws (7), 2 - 3 Nm recommended tightening torque.
Loosen the two screws (8) and rotate/set the sensor/reflector as desired, then fix by screws (8),
1Nm recommended tightening torque.
NOTE:
For It is recommended to use the Datalogic SG-M-CB connection box for electrical connections of the
SG-M kit to the Datalogic safety curtains.
For each muting system kit it is recommended to use the same sensors type kit.
Sensors must be set on Dark Mode.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product disposal at the end of its life. Datalogic
recommends disposing of the product in compliance with local laws or contacting authorised waste collection centres.
© 2015 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks and brands are property of their
respective owners. Datalogic reserves the right to make modifications and improvements without prior notification.
821003472 Rev.B
“R”
“L”
L-MUTING
T-MUTING
X-MUTING
SG-M-CB
CONNECTION BOX
ISTRUCTION MANUAL
GENERAL INFORMATION
The SG-M-CB Connection Box is part of SG-M
accessories for muting, to be used with DATALOGIC
safety light curtains of SG series, with integrated muting
function (i.e. SG BODY REFLECTOR MUTING).
Muting sensors can be connected to SG-M-CB
Connection box via M12 cables.
The signals are connected to Safety light curtain
dedicated muting connector via approx. 0.5m long pigtail
cable with M12 female connector.
Aside from the green LEDs* (to indicate sensors output
status), the SG-M-CB does not contain any electronic
elements and is therefore not subject to any safety
classification.
Features:
Supply and switching voltage +24V DC
M12 connection
Simple connection to safety light curtains.
* For correct operation of LED indicators, it is mandatory to connect
identical sensors to the four M12 sockets.
TECHNICAL DATA
Power supply &
Switching voltage: +24 VDC ±20%
Current load max.: 1 A
Insulating resistance: >1009 Ω
Mechanical protection: IP 65
Operating temperature: -10°C....+55°C
Storage Temperature: -25°C....+70°C
Housing material: PVC, Black (UL Recognized)
Housing Cable (C2): PVC, Black (UL Recognized)
Housing Connector (C1): Plug M12-5P A-Coding Female
Housing Connectors
(A1;A2;B1;B2): Sockets M12-5P A-Coding Female
Pin assignment:
PIN C1 A1 A2 B1 B2
1 24V 24V 24V 24V 24V
2 MUT2 - - - -
3 0 V 0 V 0 V 0 V 0 V
4 MUT 1 MUT 1 MUT 1 MUT 2 MUT 2
5 - - - - -
ORDER GUIDE
Model Description Order number
SG-M-CB CONNECTION BOX 95ASE2500
SG-M-CB-KIT MOUNT. KIT 95ASE2830
For each muting system kit is recommended to use same
sensors type.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales
for further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in
compliance with local laws or contacting authorised waste collection centres.
© 2015 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without
limiting the rights under copyright, no part of this documentation may be reproduced, stored in
or introduced into a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A. and the E.U. All other trademarks and brands are property of their respective
owners. Datalogic reserves the right to make modifications and improvements without prior
notification.
821003681 Rev. A
DIMENSIONS
dimensions in mm
C1

Other Datalogic Rack & Stand manuals

Datalogic BASIC HOLDER Technical manual

Datalogic

Datalogic BASIC HOLDER Technical manual

Datalogic 94ACC0175 User manual

Datalogic

Datalogic 94ACC0175 User manual

Datalogic JoyaTouch Owner's manual

Datalogic

Datalogic JoyaTouch Owner's manual

Datalogic VMK-8000 User manual

Datalogic

Datalogic VMK-8000 User manual

Datalogic VMK-P096 User manual

Datalogic

Datalogic VMK-P096 User manual

Popular Rack & Stand manuals by other brands

PEERLESS PED 410 Installation and assembly

PEERLESS

PEERLESS PED 410 Installation and assembly

Monstertech MTS CENTER JOYSTICK instruction manual

Monstertech

Monstertech MTS CENTER JOYSTICK instruction manual

Vivo MOUNT-CR70C instruction manual

Vivo

Vivo MOUNT-CR70C instruction manual

Pulsar ZRS2266GD installation guide

Pulsar

Pulsar ZRS2266GD installation guide

Vivo STAND-V102BB instruction manual

Vivo

Vivo STAND-V102BB instruction manual

Kontron R4U8S Installation and user manual

Kontron

Kontron R4U8S Installation and user manual

Panther TTS-160 user manual

Panther

Panther TTS-160 user manual

KSL SIMPLER 28EN manual

KSL

KSL SIMPLER 28EN manual

Global Truss ST-157 Setting up

Global Truss

Global Truss ST-157 Setting up

FONESTAR STV-668N instruction manual

FONESTAR

FONESTAR STV-668N instruction manual

Manfrotto 126U instructions

Manfrotto

Manfrotto 126U instructions

Mounting Dream MD2268-MK-02 installation instructions

Mounting Dream

Mounting Dream MD2268-MK-02 installation instructions

Whalen WSCSC48SB-W manual

Whalen

Whalen WSCSC48SB-W manual

Athletic FM3-A42S instruction manual

Athletic

Athletic FM3-A42S instruction manual

Maclean Brackets MC-880 installation instructions

Maclean Brackets

Maclean Brackets MC-880 installation instructions

Rose electronics GTN II Mounting instruction

Rose electronics

Rose electronics GTN II Mounting instruction

Vivo STAND V001L instruction manual

Vivo

Vivo STAND V001L instruction manual

UNIRAC 4012 Series installation manual

UNIRAC

UNIRAC 4012 Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.