DEL CONTURA-L Owner's manual

CONTURA - L
AUTOMATIC ABOVE-GROUND COVER
TECHNICAL INSTRUCTIONS Installation / Use / Cleaning / Maintenance / Safety advice

2
Maximum pool size:
Length: 10 m + steps
Width: 5 m
information
NOTICE TO BE GIVEN TO THE USER AFTER INSTALLATION IS COMPLETE
PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE.
Automatic motorised above ground safety cover using either mains electricity power.
The opening or closure operation requires about 2 minutes for one person and about 3 minutes
to lock or unlock the attachment kits.

3
information
-The motor (compliant with electric standards) is located in the tube and can
be accessed from the exterior of the terminal.
- Adjustment of the “mechanical automatic stop” locking the cover in place once
it has been fully unrolled or rolled, is done
directly on the motor.
- The electrical control box is fitted in a technical room close to the pool. (see
page 13 for the box size)
Slats:
- The cover itself is made from unleaded PVC slats (this material conforms to
anti-ageing requirements as defined in the NF T 54 405-1 Standard), they are
watertight and hinged and will float on the surface of the water.
- The gap between the side and the cover must be <= 70 mm.
- The cover is connected to the tube using white straps that are attached to the
first slat of the cover.
- There are fixture straps at the start and end of the cover used to fix the cover
to the fastening kit fixed to the side of the pool.
Fastening kits:
Push-lock
3 fixture modes: (surface mount – insert mount – hanging mount)
- The fastening kits are positioned on each width of the pool.
(the number varies depending on the pool configuration)
- These fastening systems are triggered by a tool or a double action.
Optional:
- “Chlorinator coupling” :
Connected to the roller and chlorinator control box, this option is used
to automatically reduce chlorine production when the pool is closed in order
to avoid excess chlorine in the water.
The roller:
48 cm
41 cm 21 cm
32 cm at the shaft
Cover control:
- Wi-Key “wireless”
Or
- Key switch

4
x1 x1 x2
x1
x6 x2
x8 x4
x6 x6
x1 x1 x1
x1
M8 12x60
M8x80
M8
M6
M6x16
n°4
3x16
x4
M6
x6
M8x50
DELIVERED PARTS
OPTION - CHLORINE INHIBITOR
or
Description
Option Wi-Key

5
Ø8 - 12
n°10
n°13
n° 17
T22
PACKING LIST
e.g. - for a 4 x 8 m pool
1 0.80 x 0.60 x 0.55 pallet —- 40kg
1 4.30 x 0.20 m pack —– 25 kg
4 5 x 0.25 x 0.20 m packs —– 150 kg
Total weight: 205 Kg
TOOLS
ASSEMBLY INSTRUCTIONS
3 hours
Description

6
x8
M8x5 0
D
D + 6 cm
x2
ASSEMBLY / POSITIONING / FIXTURE
Installation
Remember to have a sheath
fitted to connect the electric
control box and the motor
terminal.
see positioning
rules 1
page 7
D = (measurement between the
terminal - pool width) / 2
Instructions before installation
Install the adjustment screw

7
x1 x1
x1
Installation
Assembly
Position 1
Depending on the pool corners and the fastener kits on the roller side
motor side
Sharp corner Rounded corners or cut-off corners
Max. = 60 cm
or

8
=
=
5 mm 5 mm
Installation
Position 2
centre of the width
motor side

9
nr.17
Ø12
x2
3x16
x6
x6 x6
M8
M8 12x60
M8x80
Installation
Fix
5 mm
Fix the adjustment bar
Before fixing, check that there is an operating gap of 5 mm on each side.
(see “positioning 2” previous page)
Levelling
ground

10
n°10
M6
M6
x4 x4
x8
Installation
ASSEMBLING THE MOTOR
Make small rotating
movements with the motor
to ease its fitting.

11
Installation

12 21
34
-+F
CO
25
20
10
Installation
230 V Power supply
(U1000RO2V in a sheath) compliant with applicable standards
2 x 4 mm² - up to 16 m in length.
2 x 6 mm² - from 16 to 25 m in length.
WIRING - ELECTRIC VERSION - WI-KEY
The electric control box must be fitted in a dry room.
The installation must comply with the NF C15-100
standard and et CEI 60364
(Last applicable version) ask your electrician for advice or
contact your electricity provider.
All our control boxes use a 230 Volt single phase (50Hz)
power supply.
The required power at the input terminals is 0.15 Kw.
Upstream from the control box a suitably sized circuit
breaker with a 30 mA ground fault device must be
provided.
+ 2 x 1 mm² - STOP SEL OPTION
Wiring - refer to the manual supplied with the product

13
25
20
10
21
34
Installation
(U1000RO2V in a sheath) compliant with applicable standards
2 x 4 mm² - up to 16 m in length.
2 x 6 mm² - from 16 to 25 m in length.
The electric control box must be fitted in a dry room.
The installation must comply with the NF C15-100
standard and et CEI 60364
(Last applicable version) ask your electrician for advice or
contact your electricity provider.
All our control boxes use a 230 Volt single phase (50Hz)
power supply.
The required power at the input terminals is 0.15 Kw.
Upstream from the control box a suitably sized circuit
breaker with a 30 mA ground fault device must be
provided.
+ 2 x 1 mm² - STOP SEL OPTION
Wiring - refer to the manual supplied with the product
230 V Power supply
WIRING - ELECTRIC VERSION

14
Installation
WI-KEY INSTALLING THE CONTROL BOX
- It must be located in a place from which it is possible to check
that no one enters the pool during the manoeuvre.
- It is mandatory to install the locking «strip».
- Before fixing the control box, check that the emitter is
communicating with the receiver.
”if the motor does not run => check the power supply polarity
The support must be attached to a fixed support
Closing
Opening Stops the current action
Keyboard lock
red / green flashing = emitter locked
Emitter unlocking procedure see «page 23»
The emitter must be located outside volume 0.
The distance between the emitter and the receiver must not exceed:
- 50 m in an obstacle-free zone.
- 25 m behind a basic wall.
- 15 m behind several walls or an especially thick wall.
We recommend checking emitter/receiver communication before fixing permanently.

15
1
2
45°
Slat assembly
COVER INSTALLATION
skid
Cover start (“début de volet”) pack
Steps (“escalier”) pack
End of cover (“fin de volet”) pack
“CLICK”
along the whole
length of the slat
Repeat the movement until all the slats are completely clipped together
Make sure the slats are in the right direction
Roller
water
Installation
By clipping
By sliding
remove the cap
35 cm
If necessary, cut
the sides to ease
the passage of the
cover and avoid
rubbing
strap

XX
16
notch
skid assembly
The skids are used to orient the cover at the start of closure.
The holes are drilled at the factory.
Installation
Assembly of the strap between the cover and the tube

17
I
0
II
I
0
II
ADJUST THE AUTOMATIC STOPS
Installation
Adjustment
The arrows indicate the
cover’s direction
of movement
Turning in the +, direction will increase
the extension of the cover
Turning in the -, direction will reduce the
extension of the cover
Checking the order logic
If the command logic is not
correct, reverse wires 1 and 2
on the motor output.
(see wiring diagram)
Pool opening
Pool closure

18
x* x x x
xxxx xxxx
x
Installation
The position of the fastener kits on
the cover is indicated on the drawings
shipped with the slats.
LOCKING KITS
Without steps With Roman
steps
kit at the end
of the steps
Roman
2 kits at max.
50 cm from the
edge
kit at max.
50 cm from
the edge
1 kit centred if < 1 m
1 kit at 50 cm from the edge if < 2 m
2 kits if > 2 m
* X must never exceed 2 m
With side
steps With
straight
or trapezoidal
steps
Positioning rules
All changes to the positioning of the kits must comply with the rules given below.
For other cases please contact us.

19
Ø8
5 cm
mini
For concrete and panel pools
PUSH-LOCK INSTALLATION
For concrete and panel pools
50 mm
water level
Acceptable limit of
level variation
50 mm
Hang mounted version
Insert mounted model
Installation
A water level regulator is mandatory
50 mm
50 mm
recommended
5 cm
mini
50 mm
50 mm
For concrete and concrete block pools, as well as pools with
wall thickness greater than or equal to 8 mm
Surface mounted model
60 mm “minimum” Once the resistance
point has been
reached stop screwing,
this would deteriorate
the fixture quality.
Concrete
After reaching the
resistance point, make
3 more turns of the
screwdriver
to finish tightening.
Concrete block
Plug Washer Washer
5 cm
Ø8
VBA TF Z pozi
stainless steel A4 Ø6
x 60 wood screw
Screw cap
Hollow white
Ø16 washer
Inserted
part
Screw cap
Hang mount support
Ø12 Nylon
plug
Stainless steel nut
A4 M10
Cale
13 mm
VBA TF Z pozi
stainless steel A4
Ø6 x 60 wood screw
Hollow white
Ø16 washer
INOX
M6 washer
water level
Acceptable limit of
level variation
recommended
water level
Acceptable limit of
level variation
recommended
Universal 8 x 40 plug
VBA TF Z pozi stain-
less steel A4 Ø6 x 60
wood screw
Hollow white Ø16
washer
Screw cap

20
I
0
II
I
0
II
OPENING/ CLOSURE OF THE POOL
ALWAYS KEEP AN EYE ON THE POOL DURING OPENING OR CLOSING OPERATIONS.
ALWAYS CHECK THAT THE POOL WATER LEVEL IS CONSTANT AND COMPLIANT WITH THE
RECOMMENDATIONS ON THE INSTRUCTIONS
- It is imperative not to halt the cover in an intermediate position, this can cause the risk of jamming a bather’s body
under the cover casing, if a bather uses the pool.
- When using an automatic cleaner under the cover, check that the hose does not affect the movement of the slats
when opening and closing the cover.
- It is essential to remove floating objects when opening and closing the cover.
- Do not block the cover while extending or retracting.
- Do not activate the automatic cover when it is iced in.
- The opening or closure operation requires about 2 minutes for one person and about 3 minutes to lock or unlock
the attachment kits.
Opening: Always release the cover before starting the motor.
- Unlock all the fastening systems.
- Operate the open control.
- Lock the WI-Key command and put away the key
Closure:
- Operate the close control
- Lock all the fastener systems.
- Lock the WI-Key command and put away the key
LOCKING AND RELEASING PUSH-LOCK
Locking
Releasing
Use
Never place products that were not designed for the purpose on slat covers, as this may warp the slats.
Never leave objects on the cover (towels, buoys, etc.) because, in direct sunlight, the slats would be locally expanded
and the warranty would be void.
«Solar polycarbonate slats are incompatible with bromine treatments and treatments containing bromine.
Do not put undiluted chemical products in direct contact with solar polycarbonate slats (e.g. algae protection products).
It is essential to first carry out a test on a small surface area).»
Table of contents
Other DEL Swimming Pool manuals
Popular Swimming Pool manuals by other brands

Bestway
Bestway Inflate Your Fun FAST SET owner's manual

Paramount Pools
Paramount Pools Poolquip Lido instruction manual

treesse
treesse Muse installation manual

Bestway
Bestway Hydro-Force Sunny Lounge Island owner's manual

BSVILLAGE
BSVILLAGE Piscine London Plus manual

Blue Wave
Blue Wave NB19790 instructions