3
General
XG0226 - 042220
Contents
Safety Alert Key.................................................................................. 2
Introduction ....................................................................................... 2
Efficiency............................................................................................. 2
Section A: Before You Begin .......................................................................4
Installation Checklist ......................................................................................4
Standard Installation Checklist....................................................................5
Rating Plate Sample .......................................................................................6
Section 1: Dimensions ....................................................................... 7
DelRay Dimensions ........................................................................................7
Section 2: Framing ............................................................................ 8
In Wall and Corner Dimensions..................................................................8
Clearances........................................................................................................9
Recommended flooring considerations ...................................................9
Standard installation....................................................................................10
TV over fireplace installation......................................................................10
Vented installation .......................................................................................11
Section 3: Venting ............................................................................ 12
Section 3-3-1: Venting Layout ......................................................... 13
Wall and Roof mounted venting ...............................................................13
Co-linear venting into existing masonry chimney ................................14
Framing with Cool Wall Advantage...........................................................15
Sidewall louvers (horizontal and vert.) ..................................................15
Sidewall plenum (horizontal and vert.) .................................................15
Section 3-2: Installing a Roof Mounted Direct Vent Termination
for4''/7''(MVTK-1)............................................................................ 16
Section 3-2-1: Venting Layout ...................................................................16
Section3-3:InstallingaWallMountedTermination4''/7'' .........17
Section 3-3-2: Venting Components........................................................18
Section 3-3-2.2: 4” x 7” Venting Components........................................19
Flexmaster as alternate venting................................................................20
Section3-3-3:HeatShields4''/7''.................................................... 21
Section 4: Wiring .............................................................................. 22
DRL**13 (N/L) I Wiring Diagram ...............................................................22
Installation of the wall switch.....................................................................22
DRL**13 (N/L) I-2 Wiring Diagram ...........................................................23
Installation of Electrical Supply .................................................................23
Section 5: Installing the gas line.....................................................24
Fuel Type.........................................................................................................24
Gas Pressure .................................................................................................24
Section 5-3: GAS CONNECTION................................................................24
Finishing Safety Zone...................................................................................24
Section 6: Finishing .......................................................................... 25
Finishing Around the Fireplace .................................................................25
Finishing when using cool wall kit or vented chase .............................25
Chase venting (optional) .............................................................................26
Sidewall clearances......................................................................................27
Cement Board Install...................................................................................27
Section8:Removing&InstallingtheScreen/Door .................... 28
Removing the Screen...................................................................................28
Reinstalling the Screen................................................................................28
Removing the door ......................................................................................28
Reinstalling the door....................................................................................28
PropaneConversion ........................................................................ 29
Section 9: Installing the Accessories.............................................. 31
Installing the Fireglass or Optional Glass Media...................................31
DelRay 36" Optional Log Kit Installation .................................................31
Propane Driftwood Layout.........................................................................31
Natural Gas Driftwood Layout...................................................................31
DelRay 48" Optional Log Kit Installation .................................................32
Propane Driftwood Layout.........................................................................32
Natural Gas Driftwood Layout...................................................................32
Section 10: Cleaning and Maintenance ........................................ 34
General............................................................................................................34
Cleaning ..........................................................................................................34
Pilot Burner Adjustment. ............................................................................34
POD - Pilot on Demand.................................................................... 35
What is POD mode?.....................................................................................35
Remote Continuous Pilot (CPI) Selection ...............................................35
Installing the POD Jumper Cable ..............................................................35
Troubleshooting............................................................................................36
Indoor fireplace in protected outdoor applications ................... 37
See through fireplace..................................................................................37
Notes ...............................................................................................................37
Single sided fireplace...................................................................................37
Appendix A: Venting Terminations................................................ 38
Appendix B: Warranty ..................................................................... 39
Appendix B: Warranty Continued .................................................. 40
Appendix C: Amendment ................................................................ 41
(GasFireplace/EquipmentsoldintheStateofMassachusetts)41
DRL3613*I BASIC Exploded Parts.................................................... 42
DRL3613*I-2 FULL LOAD Exploded Parts ....................................... 43
DRL4813*I BASIC Exploded Parts.................................................... 44
DRL4813*I-2 FULL LOAD Exploded Parts ....................................... 45
Thisappliancemaybeinstalledinanaftermarket,
permanently located, manufactured home (USA
only)ormobilehome,wherenotprohibitedby
local codes.
This appliance is only for use with the type of gas
indicatedontheratingplate.Aconversionkitis
availableforthisappliance.