Hotshot Gas Fireplace Insert
P/N XG0511
Introduction
About the Hotshot:
Thank you for choosing a Delray Gas Prontigo.
The Hotshot (Model DHS) is a vented gas fireplace for installa-
tion in a masonry fireplace equipped with a double burner, glowing
embers and a 6-piece fibre logset.
The DHS is rated for Natural Gas at 25,000 BTU/H (7.4 Kilowatts)
Input or Propane at 25,000 BTU/H (7.4 Kilowatts) Input.
How to use this manual:
This manual covers installation, operation and maintenance. Light-
ing, operation and care of this fireplace can be easily performed by
the homeowner. However, all installation and service work should be
performed by a qualified or licensed contractor, plumber, gasfitter, or
installer who is qualified or licensed by the state, province, region, or
governing body in which the appliance is being installed.
Warranty and Installation Information:
The DelRay warranty will be voided by, and DelRay disclaims any
responsibility for, the following actions:
Modification of the fireplace and/or components including Direct-
Vent assembly or glass doors.
Use of any component part not manufactured or approved by
DelRay in combination with this DelRay fireplace system.
Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation require-
ments for factory-built gas fireplaces. Installations & repairs should
be done by a qualified contractor.
Installations in Canada must conform to the current CAN/CGA
B-149.1 and .2 Gas Installation Code and local regulations. If the
optional air-circulating fan kit is installed, it must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in
the absense of local codes to the National Fuel Gas Code, ANSI
Z223.1-1988. If the optional air-circulating fan is installed, it must be
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70-1987.
See Appendix A for replace installations within the State of
Massachusetts.
Table Of Contents
Introduction ............................................................................ 2
Installation
Before You Begin
Fireplace Dimensions ........................................ 3
Clearances ........................................................ 3
Installing the Gasline...................................................... 3
Chimney Liner Installation.............................................. 4
Installing the Hood ......................................................... 5
Face Plate, Trim and Louvres
Face Plate Installation ....................................... 5
Lower Louvre Assembly .................................... 6
Face Plate Trim ................................................. 6
Upper Louvre Assembly .................................... 6
Wiring for the Air Circulating Fan ................................... 7
Removing and Installing the Door.................................. 7
Installing the Logset ....................................................... 8
Operation .........................................................................9 - 10
Maintenance .................................................................. 10 - 11
Warranty ................................................................................ 12
Appendix
A. Spare Parts.............................................................. 18
B. Termination Locations.............................................. 19
CAUTIONS
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.