DENTIUM ICT MOTOR User manual

Operating Instruction

Operating Instruction iCTmotor 2
Dear Customers
The iCTmotor from Dentium is a driving engine for dental handpiece, designed for dentists to perform dental surgery
and implantology. The main unit is designed to operate a specific dental micromotor that drives dental handpiece
fitted with appropriate tools to cut hard and soft tissues in the mouth and to screw dental implants. This device is
optimized for dental implant procedure, featuring user-programmable controller to change parameters of dental
handpiece for every surgical steps of dental implant.
For the safety of both patient and dental practitioner, please read and understand this Operating Instruction prior to
the initial usage of this product. For technical support or any issues associated with this product, please contact the
authorized service center for prompt technical service.
1. Safety guidelines
2. Caution
3. Components
4. Technical specification
5. Components description
6. Product installation
7. Operation
3
3
4
5
6
7
7
8
8
9
9
11
11
11
12
Contents
5.1 Main body
5.2 Foot controller
5.3 Micromotor
6.1 Power connection
6.2 Configuration of irrigation components
6.3 Connection of irrigation tube of handpiece
6.4 Connection of components
7.1 Turn on the unit
7.2 Control panel functions
7.3 LCD display description
7.4 Program choice and modification
8. Sterilization
9. Cleaning and storage
10. Maintenance
11. Trouble shooting during operation
12. Labeling description
13. Electromagnetic compatibility
13
13
13
13
14
14
15
16
17
17
18
18
19
20
21
22
23
7.5 Program change and save
8.1 Micromotor sterilization
9.1 Main body and foot controller
9.2 Micromoto
12.1 Symbol description
12.2 Label-displaying position
Change STEP
Change RPM
Change torque
Change direction
Change the gear ratio
Change the irrigation amount
Foot controller

3 Operating Instruction iCTmotor
• The iCTmotor should be operated by dentists or authorized specialists.
• Read this User’s Manual thoroughly before operation for the first time, in order to avoid unintended incidents or accident.
• If repair or inspection is required, please contact the nearest authorized dealer.
• Sterilize all subcomponents that are subject to sterilization before each operation for disinfection.
Detailed sterilization instruction is included in this manual.
• Put the handpiece on the handpiece rack for idling during usage.
• If any abnormal condition occurs, such as unusual noise or overheated components, please stop using the device and
contact the nearest authorized dealer for support
• The foregoing warranty shall not apply to defects resulting from unauthorized disassembling or using ingenuine
components or parts. In the event of modifications by third parties, the warranty shall become null and void.
We recommend using only genuine spare parts for the operation and repair of the iCTmotor.
• Do not place similar medical electrical devices near the iCTmotor as these devices may disrupt the performance of this
device. To mitigate disruptive electromagnetic interference, position the iCTmotor away from RF transmitters and other
sources of electromagnetic energy.
• Dropping or exerting excessive forces onto the device may cause the device to malfunction or fail to meet the desired
performance standard.
• While the burr (cutting tool) is rotating, it should be handled with extra care to avoid injury of the user.
• Do not assemble or disassemble the handpiece with micromotor during operation. Before each usage, try to pull out the
handpiece from the micromotor to make sure they are well assembled.
• To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth
• Do not modify this equipment without authorization of the manufacturer
• Do not put your hand in to the irrigation pump gap
In order to avoid personal injury or property damage, please observe all safety precautions as specified in this
Operation instruction. Precautions are indicated as below.
2. Caution
The Dentium surgical micromotor iCTmotor and Implant system, are microprocessor driven surgical micromotors
used in implantology procedures. The Dentium surgical micromotors iCTmotor, consists of a microprocessor
controlled unit, foot pedal, electric micromotor, support rods and sterile, disposable, irrigation tubes.
DANGER
This symbol indicates hazadous situtions that might lead to serious physical injury or critical
property dama
1. Safety guidelines
WARNING
This symbol indicates dangerous siuation that might lead to physical harm or property damage.
NOTIFICATION
Indication for use
NOTIFICATION
This symbol indicates useful information or reference details for the user.

Operating Instruction iCTmotor 4
3. Components
※Actual components may look different with this drawing.
③
①
②
④ ⑤ ⑥ ⑦
No. Name Quantity
Main body(Including irrigation pump) 1
①Foot controller 1
②Micromotor(Including cable) 1
③Irrigation Stanchion 1
④AC power cable 1
⑤Sterilization cap 1
⑥Tube holder 10
⑦Handpiece rack 1

5 Operating Instruction iCTmotor
Dimension
Main body: 25(W)×17(D)×14(H) cm
Micromotor: Ø2.6×13.4 (L) cm
Foot controller: 18(W)×16(D)×3.8(H) cm
Material specification
Main body: Plastic
Foot controller: Plastic
Micromotor: Aluminum
Weight
Main body: 2.5 kg
Foot controller: 0.45 kg
Micromotor: 0.4 kg
Speed and torque range
of the handpiece
Rotational speed: 20 - 2000 rpm
Rotational torque: 5 - 70 N·cm
(Gear ratio 20:1)
Water-proof grade of foot controller IPX 1
Amount of inlet water
Level 1: 40 ※/min
Level 2: 50 ※/min
Level 3: 60 ※/min
Input power voltage and frequency AC100-240V~ 50/60Hz, 100VA
Operating environment
Temperature: 10 ~ 35 °C
Relative humidity: 80 % (Maximum)
Atmosphere pressure: 800 ~ 1,060 hPa
Delivery and storage
Temperature: -10 ~ +60 °C
Relative humidity: 85 % (Maximum)
Atmosphere pressure: 700 ~ 1,060 hPa
Warranty 1 year
4. Technical specification

Operating Instruction iCTmotor 6
5. Components description
5.1 Main body (iCTmotor(WH-1)
Program(STEP) up
Program(STEP) down
Handpiece connector
Mode / Memory
Data up
Data down
Irrigation pump stanchion hole
Open / Close lever
Power socket
Power switch Foot controller socket
※Actual components may look different with this drawing.

7 Operating Instruction iCTmotor
Foot switch
Program(STEP) shift
Foot connector
Micromotor connector
MicromotorHandpiece adaptor
5.2 Foot controller
5.3 Micromotor
5. Components description

Operating Instruction iCTmotor 8
6. Product installation
• Refer to the manual of the liquid and tube from the respective manufacturer to
use them properly
• The irrigation tubes are disposable. Please discard the tube after each usage.
❖Installation of the
irrigation stanchion
Place the flat part of the stanchion [Figure-3] to the top of the mainbody,andthen
insert the stanchion into the receptacle on themain body.
Plug the power connector into the socket [Figure-1] on the back of the main body
❖Power cord connection
6.1 Power connection
6.2 Configuration of irrigation components
[Figure-1] [Figure-2]
[Figure-3] [Figure-4] [Figure-5]
❖Insertion of the
irrigation tube
1) Rotate the OPEN/CLOSE lever to "OPEN” position to open the cover for tube
insertion. [Figure-6]
2) Insert the irrigation tube into the adapter by using both hands.
Place the irrigation tube right in the middle of the roller so that it is not kinked or
crushed. [Figure-7] Turn the OPEN/CLOSE lever to "CLOSE” after the irrigation
tube is placed properly in the tube guide
[Figure-6] [Figure-7]
• Dry your hand completely before connecting the power cable
• This product has the Free voltage function (AC100-240V~ 50/60Hz)
• To avoid risk of electric shock, this equipment must only be connected to a
supply mains with protective earth
WARNING
WARNING

9 Operating Instruction iCTmotor
6. Product installation
• More detailed information on the handpiece can be referred to the user manual
of handpiece or contra-angle provider
• The irrigation tube is a disposable. Do not reuse it.
6.3 Connection of irrigation tube of handpiece
• Before plugging or unplugging the connectors, be sure to turn “OFF” the power
of the main body.
• Make sure the mark [㎖] imprinted on the connector is facing up and then plug it
into the connector socket
• The life-time of micromotor and handpiece may rapidly be reduced by over heat
from continuous operation. It is recommended to follow operation time specified
below.
LCD will show this error message if the handpiece is disconnected or not con-
nected well. Check the connection for normal usage.
LCD will show this error message if the foot connector is disconnected or not
connected well. Check the connection for normal usage.
6.4 Connection of components
[Figure-8] [Figure-9]
Locate the marking [㎖] of the connector joint upward and push it into the micromo-
tor socket to connect. [Figure-8]
※It will make a "click” sound at the joint when correctly connected.
❖Micromotor
connection
When disconnecting, grab and pull the connector joint.
❖Micromotor
disconnection
WARNING
Maximum duration of non continuous usage (Load Time): 3 Minutes,
Cooling interval between each procedure (Colling Time): 10 Minutes
WARNING
WARNING

Operating Instruction iCTmotor 10
6. Product installation
1) Align the foot connector key with the socket and then insert it.[Figure-10]
2) Turn the tightening nut clockwise.
[Figure-10]
❖Connection of
foot controller
1) Turn the tightening nut counterclockwise.
2) When disconnecting, Grab and pull the tightening nut.
[Figure-11]
❖Foot controller
disconnection

11 Operating Instruction iCTmotor
7. Operation
Power switch (I/O) can be found in the back side of the product. Press “I” side
down.
7.1 Turn on the unit
7.2 Control panel functions
Button Description of Function
Move the user program (“STEP”) up
Move the user program (“STEP”) down
Activate the data mode to initiate program modification and save the changed data
Increase the data cursor is on
Decrease the data cursor is on.
7.3 LCD display description
A
B
C
D
F
E
G
A) Displays the current STEP. (STEP 1 ~ 6)
B) Displays the rpm currently set. (It displays the real-time rpm while the motor runs.)
C) Displays the torque currently set. (It displays the real-time torque while the motor runs.)
D) Displays the rpm gauge setting as the ratio graphic.
E) Displays the rotational direction of the handpiece.
(The letters F and R stand for "FORWARD” and "REVERSE” respectively)
F) Displays the gear reduction ratio of the handpiece.
G) Displays the irrigation flow rate.

STEP Ratio Process rpm Torque Pump Direction
1 20 : 1 Drilling 1000 35
2 20 : 1 Countersinking 300 35
3 20 : 1
Implant Insertion
or
Tapping
20 35
4 20 : 1 Cover & Healing con-
nection 100 5
5 20 : 1 Removal 20 55
6 20 : 1 Spare 20 5
Operating Instruction iCTmotor 12
[Table-1]
❖PROGRAM(STEP) INFORMATION
iCTmotor provides you with the optimized program solution for each STEP of protocol for the Dentium implant
installation as default from the factory as below <Table-1>. This program can be changed by the user according to
preferences.
7. Operation
7.4 Program choice and modification
Please note that the above details are not the standard guidance for every implant system.
NOTIFICATION

13 Operating Instruction iCTmotor
1) Program button “ ” will move the steps upward (STEP 1-2-3-4-5-6)
- If you press the button continuously, steps will rotate.
(The Program move key in the Foot pedal unit will make the same change.)
2) Program button “ ” will move the steps downward (STEP 6-5-4-3-2-1)
- If you press the button continuously, steps will rotate.
⇔The rpm will increase / decrease by the increment value specified in the below
Table-2.
⇔The torque will increase / decrease by the increment
value of 5 N∙cm
❖Change STEP
1) Press the SELECT “ ” button to activate the cursor.
2) Move the cursor to the rpm change sector by
pressing the “SELECT” button repeatedly.
3) Press “ ” or “ ” button set the target rpm value.
4) Press "SELECT” to save the rpm value displayed on
the LCD display.
(It will save the value automatically if the value is not
changed in 5 seconds)
❖Change RPM ※Torque may become fluctuated(+/- 10%) in the torque below 5 N∙cm.
1) Press the SELECT “ ” button to activate the cursor.
2) Move the cursor to the torque change sector by
pressing the “SELLECT” button repeatedly.
3) Press “ ” or “ ” button to set target torque value.
4) Press “SELLECT” to save the torque value displayed
on the LCD Display.(It will save the value automatically
if the value is not changed in 5 seconds)
❖Change torque
Setting rpm Increment
15 - 50 5
60 - 100 10
200 - 2000 100
(Unit: rpm)
※Rotation speed may become fluctuated (+/- 10%) in the speed below 25 rpm.
[Table-2]
7. Operation
7.5 Program change and save
All program changes completely after stopping the operation of the machine must
be running.
WARNING

Operating Instruction iCTmotor 14 ※The available rpm and torque ranges respect to the gear ratio are shown as in
the Table-3.
1) Press the SELECT “ ” button to activate the
cursor.
2) Move the cursor to the Gear ratio change
sector by pressing the “SELECT” button
repeatedly.
3) Press “ ” or “ ” button to change the gear
ratio.
4) Press “SELECT” to save the gear ratio displayed
on the LCD display.
(It will save the value automatically if the value is
not changed in 5 seconds)
❖Change the gear ratio
Gear ratio rpm Torque(Ncm)
20 : 1 20 - 2000
5 - 70 Ncm27 : 1 15 - 1400
32 : 1 15 - 1200
[Table-3]
• Long beep sound will be given continuously if you put the rotation as reverse
direction by the conrtol panel, and short beep sound by the foot controller.
• “F” stands for Forword, and “R” stands for Reverse.
1) Press the SELECT “ ” button to active the
cursor
2) Move the cursor to the rotating direction
change sector by pressing the “SELECT”
button repeatedly.
3) Press “ ” or “ ” button to change direction.
4) Press “SELECT” to save the direction displayed
on the LCD display.
(It will save the value automatically if the value is
not changed in 5 seconds)
❖Change direction
7. Operation
NOTIFICATION

15 Operating Instruction iCTmotor
Step marking Irrigation amount(Max)
OFF
40 ※
50 ※
60 ※
[Table-5]
(unit: ※/min)
※Water irrigation can be disabled by pressing the “ ” or “ ” button.
※Irrigation amount can be adjusted in 3 steps. Please refer to the below table
for the amount of irrigation in each step.
1) Press the “SELECT ” button to activate the
cursor.
2) Move the cursor to the Irrigation amount
change sector by pressing the “SELECT”
button repeatedly.
3) Press “ ” or “ ” button to change the irrigation
amount
4) Press “SELECT” to save the irrigation amount
displayed on the LCD display.
(It will save the value automatically if the value is
not changed in 5 seconds.)
❖Change the irrigation
amount
7. Operation
This compatibility chart is subject to change without notice in advance. The brand
and product names are trademarks or their respective companies.
Manufacturer Model Gear ratio Maximum torque
W&H(Austria ) WI–75 E/KM 20 : 1 5 - 70 Ncm
Bien-Air(Swiss) CA20 : 1 20 : 1 5 - 55 Ncm
[Table-4]
⑧Compatible contra-angles are summarized in the Table-4. Follow the instructions
of respective manufacturer for the maintenance or detailed practical usage.
WARNING

Operating Instruction iCTmoto 16
7. Operation
⑧The device makes short beep sounds when the actual torque value reaches
90% of the target torque value. Once torque value reaches 100% of the target
torque, the device makes long beep sound and the Micromotor will stop in 0.5
second.
⑧The device will make short beep sounds if the handpiece is working in reverse
direction.
⑧The parameters can be adjustable (STEP change) only if the device has come
to complete stop.
❖Foot controller
Standard Option
Other genuine optional components can be used after proper configuration fuided
by the manufacturer.
NOTIFICATION

17 Operating Instruction iCTmotor
8. Sterilization
[Figure-12]
1) Block the handpiece connector's opening with a sterilization cap to avoid steam penetration into the device.
[Figure-12].
2) Pack and seal the micromotor (including cable) in the high-pressure sterilization pouch.
3) Sterilize using high-pressure steam.
8.1 Micromotor sterilization
Please follow the instructions in the below to prevent secondary infection due to contamination of the equipment.
• If sterilized without the sterilization pouch, the equipment may get damaged.
• The parts that can be sterilized using high-pressure steam are Micromotor (including
cable) and the handpiece rack.
• Sterilize and clean the equipment before operation.
• When sterilizing with high-pressure steam, wrap and seal the equipment with the sterilizing
pouch.
• Please cool off sufficiently and dry the parts stenilized by high-pressure steam before use.
WARNING
DANGER
Working condition of high-pressure steam:
Maximum 134, more than 5 minutes and less than 20 minutes
The manimum number of Sterilization: 100 times
WARNING

Operating Instruction iCTmotor 18
9. Cleaning and storage
1) Wash outside of the equipment body only by using 80% of ethylic alcohol or the exclusive cleaning solution for
prevention of microbial infection. Be careful not to let the buttons be damaged by excessive force or sharp
object.
2) Please do not let alien substances such as detergent or water get into the main body.
9.1 Main body and foot controller
1) Please do not let any liquid substance permeate in the micromotor connector.
2) Store the micromotor and handpiece separately.
9.2 Micromotor
• Electrical components MUST be disconnected with the A/C power when cleaning.
• DO NOT bend the power cabel, micromotor cable or foot controller cable.
• AVOID cleaning the device and sub-components using the compressed air by nozzle.
WARNING
• DO NOT disassemble the micromotor itself.
(The foregoing warranty shall not apply to defects resulting from disassembling)
WARNING

19 Operating Instruction iCTmotor
10. Maintenance
• Make it sure that the sheath of the cables has not been peeled off. Please coil the cables round to store.
• In case any abnormal condition occurs, such as unusual noise or over-heating of the components, please stop
using the product and contact the nearest authorized Dentium dealer for technical support.
• It generally applies that disposal of this product must comply with the relevant national regulations.
Unit Check list
Main Body
1) Is the power switch of the idling equipment set as "O"?
2) Is there any damage in the display panel and buttons?
3) Are the display color and data being displayed vividly?
Micromotor
1) Is the micromotor cable not damaged?
2) Is there any damage in the micromotor connector?
3) Has any screw loosened in the micromotor?
Foot-controller 1) Is the foot connector not damaged?
2) Is the foot controller running smoothly when operating up and down?
10.1 Daily check point

Operating Instruction iCTmotor 20
11. Trouble shooting during operation
Troubles Cause & Solution Page
Display not working
Cause A. Power supply is not stable.
9
Solution
a1. Plug out the power socket from the consent, wait for 5 sec-
onds and plug in.
a2. Press the power button On (“I”).
Buttons not working
Cause
A. Device is in working mode or previous orders are not
processed.
B. Designated value has not been activated. 15~17
Solution a. Wait until the device gets to a complete stop and try again.
b. Use the “SELECT” button to activate the selected value.
Handpiece not working
Cause A. Handpiece got dirt or out of order.
B. Foot controller or Motor connector is improperly connected
10~11
Solution
a. Refer to the manual for the handpiece from the manufacturer.
b. Remove and reconnect the connectors or check the
connections
Irrigation not working
Cause
A. Irrigation tube is damaged or blocked.
B. Irrigation stopper is tightened.
C. Irrigation mode is not activated.
D. Irrigation tube is improperly connected.
9~10
Solution
a. Replace the tube or clean the handpiece nozzle.
Refer to the manual of the handpiece for cleaning.
b. Open the stopper.
c. Activate the Irrigation mode.
d. Disconnect and reconnect the foot controller or micromotor.
[Table-6]
• Device check up must be done in the environment of no water or moisture.
• Power must be off for trouble shooting process.
• Below <Table-6> shows simple troubles thats user can fix. If none of the below optipons
correct the problem, please contact the nearest authorized dealer.
WARNING
Table of contents
Popular Dental Equipment manuals by other brands

Amanngirrbach
Amanngirrbach Stemaer X3 operating instructions

i-onyx
i-onyx LOCAPEX FIVE Operation instructions

mectron
mectron STARJET Use and maintenance manual

Renfert
Renfert AUTO spin Instructions for use

KaVo
KaVo INTRA LUX KL 703 LED Instructions for use

DENTAURUM
DENTAURUM Titan-hyrax Maxi - 12 Instructions for use