Dexing NDS3508B User manual

NDS3508B Tuner to IP Gateway
User’s Manual
DEXIN DIGITAL TECHNOLOGY CORP. LTD.

DIRECTORY
CHAPTER 1 PRODUCT OUTLINE.................................................................................................. 1
1.1 Outline............................................................................................................................................................ 1
1.2 Features.......................................................................................................................................................... 1
1.3 Inner Principle ............................................................................................................................................... 1
1.4 Specifications .................................................................................................................................................. 2
1.5 Appearance and Description.......................................................................................................................... 2
CHAPTER 2 INSTALLATION GUIDE............................................................................................ 5
2.1 Acquisition Check .......................................................................................................................................... 5
2.2 Installation Preparation................................................................................................................................. 5
2.3 Wire’s Connection .......................................................................................................................................... 7
CHAPTER 3 WEB NMS OPERATION............................................................................................ 8
3.1 login................................................................................................................................................................ 8
3.2 Operation ....................................................................................................................................................... 8
CHAPTER 4 TROUBLESHOOTING............................................................................................ 18
CHAPTER 5 PACKING LIST.......................................................................................................... 19

NDS3508B Tuner to IP Gateway User’s Manual
1
Chapter 1 Product Outline
1.1 Outline
NDS3508B Tuner to IP Gateway is a head-end interface conversion device which
supports MPTS and SPTS output switchable. It supports 16 MPTS or 512 SPTS output
over UDP and RTP/RTSP protocol. It is integrated with tuner demodulation (or ASI input)
and gateway function, which can demodulate the signal from 16 tuners into IP package,
or directly convert the TS from ASI input and tuner into IP package, then output the IP
package through different IP address and ports. BISS function is also embedded for tuner
input to descramble your tuner input programs.
1.2 Features
Support 16 FTA DVB- S/S2/S2X input, 2 ASI input
Support BISS descrambling
Support DisEqc function
16 MPTS or 512 SPTS output (MPTS and SPTS output switchable)
2 GE mirrored output (IP address and port number of GE1 and GE2 are different), up to
850Mbps---SPTS
2 independent GE output port, GE1 + GE2---MPTS
Support PID filtering, re-mapping (Only for SPTS output)
Support “Null PKT Filter” function (Only for MPTS output)
Support Web operation

NDS3508B Tuner to IP Gateway User’s Manual
2
1.3 Inner Principle
Tuner 1
Tuner 2
Tuner 3
Tuner 15
Tuner 16
IP Output
ASI Input1
ASI Input2
NDS3508B
GE1
GE2 IP Output
1.4 Specifications
Input
Optional 1:16 tuners input +2 ASI input---SPTS output
Optional 2:14 tuners input +2 ASI input --- MPTS output
Optional 3:16 tuners input --- MPTS output
Tuner Section
DVB-S
Frequency In
950-2150MHz
Symbol rate
0.5~45Msps
Signal Strength
- 65- -25dBm
FEC
1/2, 2/3, 3/4, 5/6, 7/8
Constellation
QPSK
Max input bitrate
≤125 Mbps
DVB-S2
Frequency In
950-2150MHz
Symbol rate
QPSK/8PSK /16APSK :0.5~45 Msps
32APSK: 0.5~34Msps;
FEC
QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
16APSK: 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
32APSK: 3/4, 4/5, 5/6, 8/9, 9/10
Constellation
QPSK, 8PSK, 16APSK, 32APSK
Max input bitrate
≤125 Mbps
DVB-S2X
Frequency In
950-2150MHz
Symbol rate
QPSK/8PSK /16APSK :0.5~45 Msps
8APSK: 0.5~40Msps
32APSK: 0.5~34Msps
FEC
QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10, 13/45,
9/20, 11/20
8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
8APSK: 5/9-L, 26/45-L
16APSK: 2/3, 3/4, 4/5, 5/6, 8/9, 9/10, 1/2-L, 8/15-L,
5/9-L, 26/45, 3/5, 3/5-L, 28/45, 23/36 , 2/3-L, 25/36,

NDS3508B Tuner to IP Gateway User’s Manual
3
1.5 Appearance and Description
Front Panel Illustration:
13/18, 7/9, 77/90
32APSK: 3/4, 4/5, 5/6, 8/9, 9/10, 2/3-L, 32/45, 11/15,
7/9
Constellation
QPSK, 8PSK, 8APSK, 16APSK, 32APSK
Max input bitrate
≤125 Mbps
BISS
Descrambling
Mode 1, Mode E (Up to 850Mbps) (descramble individual program)
Output
512 SPTS IP mirrored output over UDP and RTP/RTSP protocol through GE1 and GE2
port (IP address and port number of GE1 and GE2 are different) , Unicast and Multicast
16 MPTS IP output (for Tuner/ASI passthrough) over UDP and RTP/RTSP protocol
through GE1 and GE2 port, Unicast and Multicast
System
Web based management
Ethernet software upgrade
Miscellaneous
Dimension
482mm×410mm×44mm (W×L×H)
Approx weight
3.6kg
Environment
0~45℃(work);-20~80℃(Storage)
Power requirements
100~240VAC, 50/60Hz
Power consumption
20W
1
Power indicator
2
Reset: Reset webmaster IP address, recover it to default IP address
3
USB port for upgrade
4
NMS port: Network management interface
5
Data port(GE1&GE2): IP out port
6
ASI input port

NDS3508B Tuner to IP Gateway User’s Manual
4
Rear Panel Illustration
1
16 channels RF IN Interface
2
Integrated power switch and socket
3
Grounding Wire

NDS3508B Tuner to IP Gateway User’s Manual
5
Chapter 2 Installation Guide
2.1 Acquisition Check
When users open the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
NDS3508B Tuner to IP Gateway
Grounding Cable
RF In and Loop Out Cable
Power Cord
If any item is missing or mismatching with the list above, please contact local dealer.
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will be
described at the rest part of this chapter. Users can also refer rear panel chart during the
installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing gateway
Connecting signal cables
Connecting communication port (if it is necessary)
2.2.1 Device’s Installation Flow Chart Illustrated as following:
Connecting
Grouding
Wire and
Power
Cord
Acquisition
Check Fixing
Device Setting
Parameter Running
Device
Connecting
Signal Wire
2.2.2 Environment Requirement

NDS3508B Tuner to IP Gateway User’s Manual
6
Item
Requirement
Machine Hall Space
When user installs machine frame array in one machine hall, the
distance between 2 rows of machine frames should be 1.2~1.5m
and the distance against wall should be no less than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative
Temperature
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual level
glasses for window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires AC
power 100V-240V 50/60Hz 2A. Please carefully check before
running.
2.2.3 Grounding Requirement
All function modules’ good grounding designs are the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
Coaxial cable’s outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be

NDS3508B Tuner to IP Gateway User’s Manual
7
antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no less
than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and avoid circling. The area of the conduction between
grounding wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is
on the left ,power supply socket is on the right and the fuse is just between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end toAC power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to NDS3508B Tuner to IP Gateway, user should set the
power switch to “OFF”.

NDS3508B Tuner to IP Gateway User’s Manual
8
Chapter 3 WEB NMS operation
User can only control and set the configuration in computer by connecting the device to web
NMS Port. User should ensure that the computer’s IP address is different from the
NDS3508B’s IP address; otherwise, it would cause IP conflict.
3.1 login
The default IP of this device is 192.168.0.136.
Connect the PC and the device with net cable, and use ping command to confirm they are on
the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx
can be 0 to 255 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting this device’s IP address in the
browser’s address bar and press Enter.
It displays the Login interface as Figure-1. Input the Username and Password (Both the
default Username and Password are “admin”.) and then click “Login” to start the device
setting.
Figure-1
3.2 Operation
Summary →Status
When we confirm the login, it displays the status interface as Figure-2.

NDS3508B Tuner to IP Gateway User’s Manual
9
Figure-2
Parameter→Tuner input (DVB-S2/S2X)
From the menu on top side of the webpage, click “Tuner Input”, it displays the interface
where users can check the 16 DVB-S/S2/S2X Tuners input status. (Figure-4)
Figure-4
User can click any item here to enter
the corresponding interface to check
information or set the parameters.
System information
16 DVB-S-S2-S2X
Tuner input status

NDS3508B Tuner to IP Gateway User’s Manual
10
Parameter→ASI input
From the menu on top side of the webpage, click “ASI Input”, it displays the interface where
users can check the 2 channels of ASI input status. (Figure-5)
Figure-5
Parameter→TS Config
Clicking “TS Config”, it displays the interface where users can set the output TS and
configure TS ID and ON ID (Figure-6).
Figure-6
Parameter→BISS
From the menu on left side of the webpage, clicking “BISS”, it displays the interface where
users can configure BISS and descramble the input channels (Figure-7).

NDS3508B Tuner to IP Gateway User’s Manual
11
Figure-7
Parameter →SPTS Select:
From the menu on left side of the webpage, clicking “SPTS Select”, it displays the interface
where users can choose 16 DVB-S/S2/S2X Tuner input and 2 ASI Input programs to output
from IP (max 512 SPTS). (Figure-8)
Figure-8
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as
below:
: To filter/not filter the source CA information
: To enable/disable the PID remapping
To refresh the input program information
Input Area
Output Area
Operation Area

NDS3508B Tuner to IP Gateway User’s Manual
12
To refresh the output program information
Select one input program first and click this button to transfer the selected
program to the right box to output.
Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs
To parse programs time limitation of parsing input programs
Program Modification:
The multiplexed program information can be modified by clicking the program in the ‘output’
area. For example, when clicking , it triggers a dialog box (Figure 9) where users
can input new information.
Figure-9
Note: NDS3508B support 16 Tuner input and 2 ASI input with 512 SPTS output, the
parameter interface is different from MPTS. When users switch SPTS to MPTS, new mode
will work after reboot the device.
Parameter→BISS:
From the menu on left side of the webpage, clicking “BISS”, it displays the interface where
users can configure BISS and descramble the input channels (Figure-10).

NDS3508B Tuner to IP Gateway User’s Manual
13
Figure-10
Parameter→Program Parse
From the menu on left side of the webpage, clicking “Program Parse”, it displays the interface
where users can parse the program from the input channels.
When users disable the ASI input, NDS3508B can support 16 Tuner input with 16 MPTS IP
output (Figure-11).
Figure-11
When users enable the ASI input, NDS3508B can support 14 Tuner input and 2 ASI input
with 16 MPTS IP output (Figure-12).
Select the output carrier
Enable and Disable the
ASI input

NDS3508B Tuner to IP Gateway User’s Manual
14
Figure-12
Parameter→IP Stream
NDS3508B supports TS to output in IP (16*MPTS) format through the GE1 or GE2 port.
Clicking “IP Stream”, it displays the interface where to set IP out parameters (Figure-13).
Figure-13
System → Network:
Clicking “Network”, it displays the interface as Figure-14 where to set network parameters.

NDS3508B Tuner to IP Gateway User’s Manual
15
Figure-14
System → Date &Time:
Clicking “Date & Time”, it displays the interface as Figure-15 where to set date and time.
Figure-15
System → Password:
From the menu on left side of the webpage, clicking “Password”, it displays the screen as
Figure-16 where to set the login account and password for the web NMS.
Set GE1 IP address
Set NMS IP address, the
default IP address is
192.168.0.136
Set GE2 IP address

NDS3508B Tuner to IP Gateway User’s Manual
16
Figure-16
System → Save/Restore:
From the menu on left side of the webpage, clicking “Save/Restore”, it displays the screen
as Figure-17 where to save or restore your configurations.
Figure-17
System → Backup/Load:
From the menu on left side of the webpage, clicking “Backup/Load”, it displays the screen
as Figure-18 where to backup or load your configurations.

NDS3508B Tuner to IP Gateway User’s Manual
17
Figure-18
System → Firmware:
From the menu on left side of the webpage, clicking “Firmware”, it displays the screen as
Figure-19 where to update firmware for the device.
Figure-19
Select IP output
Mode, click “Apply”
and reboot the device
then the new mode
can start to work.

NDS3508B Tuner to IP Gateway User’s Manual
18
Chapter 4 Troubleshooting
DEXIN’s ISO9001 quality assurance system has been approved by CQC organization. For
guarantee the products’ quality, reliability and stability. All DEXIN products have been passed
the testing and inspection before ship out factory. The testing and inspection scheme already
covers all the Optical, Electronic and Mechanical criteria which have been published by
DEXIN. To prevent potential hazard, please strictly follow the operation conditions.
Prevention Measure
Installing the device at the place in which environment temperature between 0 to 45 °C
Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores
if necessary
Checking the input AC within the power supply working range and the connection is
correct before switching on device
Checking the RF output level varies within tolerant range if it is necessary
Checking all signal cables have been properly connected
Frequently switching on/off device is prohibited; the interval between every switching
on/off must greater than 10 seconds.
Conditions need to unplug power cord
Power cord or socket damaged.
Any liquid flowed into device.
Any stuff causes circuit short
Device in damp environment
Device was suffered from physical damage
Longtime idle.
After switching on and restoring to factory setting, device still cannot work properly.
Maintenance needed
Table of contents
Popular Gateway manuals by other brands

OpenVox
OpenVox Analog Gateway Series user manual

Patton electronics
Patton electronics SmartNode 4130 user manual

Helmholz
Helmholz WALL IE 700-860-WAL01 quick start guide

COTX
COTX X3 quick start guide

Mioty
Mioty Premium Gateway user manual

ProSoft Technology
ProSoft Technology ProLinx 5604-RIO-PDPMV1 Setup guide