HYDRUS
Performance of volume test
•Activate the test mode as described under General procedure.
•After activating the meter display alternately indicates “Out 4” and the high-resolution
volume, e.g. 0.000000 m³ (Fig. D).
Fig. D Meter display with activated test mode
•HYDRUS now provides an output of the test pulse value for 3 hours shown in the display.
The value depends on the nominal size of the meter (Fig. E).
TEST PULSE VALUES:
Q3 TEST PULSE VALUES PULSE DURATION
OPTOHEAD
Fig. E Test pulse values
•To end the test, briefly press button (
Optical test pulses OFF
) by holding the remote
control via the optical interface.
•The yellow “ACT” LED on the device (see Fig. C) glows to indicate that the remote control is
in operation.
•HYDRUS display no longer indicates “Out 4”.
•To prevent accidental discharge of the battery, always end the test by pressing button
(
Optical test pulses OFF)
and check that "Out 4” is no longer indicated on the display of
HYDRUS.