Direct Air RG57A3/BGEF User manual

CR103-RG57A3
Thank you very much for purchasing our products.
Please read this manual carefully before using the
remote controller.
The design and specifications are subject to change without
prior notice for product improvement. Consult with the sales
agency or manufacturer for details.
REMOTE CONTROLLER ILLUSTRATION
(Function selection)

1
2
2
4
Handling the remote controller ...................................
Remote controller specification...................................
Features of remote controller buttons .......................
How to set up the funcitons.........................................
CONTENTS
Keep the remote controller where its
signals can reach the receiver of the
indoor unit. (a distance of 8m is allowed).
Location of the remote controller.
8m
CAUTIONS
The air conditioner will not operate if curtains, doors or other
materials block the signals from the remote controller to the indoor
unit.
Prevent any liquid from falling into the remote controller. Do not
expose the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct
sunlight, the air conditioner may not function properly. Use curtains
to prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller, either
move these appliances or consult your local dealer.
The remote controller uses two
alkaline dry batteries (R03/LR03X2)
(1) Slide the cover of the battery
compartment off according to the
arrow direction, then replace the
old batteries with new ones.
(2) Insert the new batteries, making
sure that the(+) and (-) of battery
are installed correctly.
(3) Reattach the cover by sliding it
back into position.
NOTE:
Do not mix old and new batteries
or batteries of different types.
Do not leave the batteries in the
remote controller if they are not
going to be used for 2 or 3 months.
Do not dispose batteries as
unsorted municipal waste.
Collection of such waste separately
for special treatment is necessary.
Replacing batteries
Handling the remote controller
1
POWER
OFF
MODIFY
ADJUST
CONFIRM

2
3
Model
Rated Voltage
RG57A3/BGEF
。 。
-5 C 60 C
8m
3.0V(Dry batteries R03/LR03×2)
~
Remote Controller Specification
Environment
Signal Receiving Range
Features of Remote Controller buttons
ON/OFF
MODE
TEMP
TIMER ON
TIMER OFF
POWER OFF button: Press this button to turn off
the unit
TIMER ON button:Press this button to confirm the
setting parameter and transmit the singal to the
machine.
FAN & TIMER OFF button: On parameter setting
interface, pressing FAN & TIMER OFF button to
select parameter to be modified.
TEMP & button: Used to choose
functions or adjust parameters. On parameter
unadjustable interface, press the &
button to select the specified function in a
range of F1 ~ F9 and E1~E9. Then pressing the
MODE button to enter the parameter modifying
interface, the relevant parameter flashes, pressing
& button to adjust the paramter.
MODE button: Used to modify the selected
function. Press this button to enter the parameter
setting interface, and the parameter to be modified
will be kept flashing. Using TEMP &
button to modify the parameter or choosing the
other parameter in conjuction with FAN & TIMER
OFF button.
LOCK button: Hold and press this two buttons for
2 seconds, all current settings of indoor unit are locked
in and the remote controller does not accept any
operation except that of the LOCK.
NOTE: After installing the batteries,
period, please holding down the MODE, FAN and TIME ON
buttons together for 5 seconds, the remote controller will enter
function reset state, and LCD window displays F1 .
during the first 30 seconds
IMPORTANT: The remote controller is only enabled within10
minutes after the indoor unit is powered on, and the indoor unit
must be switched off.
MODE
FAN
FAN
TEMP
SLEEP FRESH
SLEEP FRESH
LED FOLLOW ME
TURBO SELF CLEAN
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF

4
5
Auto-start function
Heating temperature compensation
1. Press & button to choose F2.
1. Press &
button to choose F1.
2. Press MODE button. Then
press & button to
choose On or Off .
2. Press MODE button. Then press & button to
choose the parameter. The parameters can be adjusted
O O
within a range of -6 C~6 C.
How to set up the functions
TEMP
TEMP
ADJUST
MODE
MODE
3. Press TIMER ON button, and the Auto-start function on/off
setting has finished.
3. Press TIMER ON button.
TIMER ON
TIMER ON
NOTE: The indoor unit will beep for 2 seconds indicating the
function being set up successfully.
Anti-cold air function
Intelligent anti-cold air function setting:
1. Press & button to choose F3.
TEMP
NOTE: The parameter of intelligent anti-cold air is changed with the
room temperature. After the room temperature raised, the temperature
of anti-cold air would raise too, which can make you feel more comfortable.
After the room temperature decreased, the anti-cold air temperature
would decrease too, which can improve the fan speed and bring fast
heating operation.
-
---
--.... ....
....
....
Flashing
Flashing
3.Press TIMER OFF button to adjust the parameter. The parameter
keeps flashing. Then press & button to adjust the
O O
parameter in the range of 17 C~21 C.
2. Press MODE button. Press FAN button to to choose
parameter . Then press & button to select 1 .
MODE
TIMER OFF
FAN
4. Press TIMER ON button to confirm.
TIMER ON
TEMP
TEMP

6
7
Flashing
Flashing
3.Press TIMER OFF button to adjust the parameter. The parameter
keeps flashing. Then press & button to adjust the
O O
parameter in the range of 8 C~28 C.
1. Press & button to choose F3.
TEMP
TEMP
TEMP
2. Press MODE button. Press FAN button to to choose
parameter . Then press & button to select 2 .
MODE
TIMER OFF
FAN
4. Press TIMER ON button to confirm.
TIMER ON
General Anti-cold air function setting:
NOTE: The parameter of general anti-cold air is fixed regardless
of room temperature.
Speed control of indoor fan motor after the set
temperature reached
1. Press & button to choose F4.
TEMP
TEMP
2. Press MODE button. Then press & button to
select 1 , 2 , 3 or 4 .
MODE
Indicates stopping fan motor
Indicates operating at lowest fan speed
Indicates operating at setting fan speed
Indicates Termal function
3. Press TIMER ON button.
TIMER ON

8
9
1. Press & button to choose F6.
1. Press & button to choose F5.
TEMP
TEMP
TEMP
TEMP
2. Press MODE button. Then press & button to
select HH or CH. (HH: Heating only, CH: Cooling
& Heating)
2. Press MODE button. Then press & button to
select 1 , 2 or 3 .
MODE
Indicates cancelling memory function.
Indicates the louver angle memory function is enabled
under switching off or power failure.
Indicates the louver angle memory function is enabled
under switching off, disabled under power failure.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
TIMER ON
Heating only or Cooling & heating setting
Louver angle memory function
Cooling temperature compensation
Refrigerant leakage detection
1. Press & button to choose F7.
1. Press & button to choose F8.
2. Press MODE button. Then press & button to
O O
choose the parameter in a range of -2 C~2 C.
2. Press MODE button. Then press & button to
choose on or of .
TEMP
TEMP
MODE

10
11
Cleaning Filter Reminder
Filter Replacement Reminder
Lowest temperature setting
High temperature setting
1. Press & button to choose F9.
1. Press & button to choose E1. 1. Press & button to choose E4.
1. Press & button to choose E5.
1. Press & button to choose E2.
1. Press & button to choose E3.
TEMP
TEMP TEMP
TEMP
TEMP
TEMP
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm. 3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press & button to
choose on or of .
2. Press MODE button. Then press & button to
choose on or of . 2. Press MODE button. Then press & button to
choose on or of .
2. Press MODE button. Then press & button to
choose H or C.
2. Press MODE button. Then press & button to
O O
set the temperature in a range of 17 C to 24 C.
2. Press MODE button. Then press & button to
O O
set the temperature in a range of 25 C to 30 C.
Special Anti-cold air function setting:
Priority setting of heating or cooling
(applicable for multi models)
: Heating mode first
: cooling mode first

12
13
Network Address setting
Capacity code selection
Twins setting
1. Press & button to choose E6.
1. Press & button to choose E7.
1. Press & button to choose E9.
1. Press & button to choose E8.
TEMP
TEMP
TEMP
TEMP
3. Press TIMER ON button to confirm.
Some functions of the remote controller will not
be available when the unit does not support them!
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press & button to
choose the network address between 0 to 63 or .
Indicates cancelling the the adress modified by remote
controller (determined by code switch) .
2. Press MODE button. Then press & button to
choose the capacity code between 0~11.
(0~3: Reserved number), 4: 18K model, 5: 24K model,
7: 30K model, 8: 35K model, 9: 48K model, 10: 54K model
11: 60K model.
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press & button to
choose the value between 0 and 4.
2. Press MODE button. Then press & button to
choose 0(no twins), 1(main unit) or 2(subsidiary unit)
Static pressure setting
--
--
NOTES

14
15
Point check function
Enquiry information
Enquiry
information
Display
value Meaning Remark
Displaying code Meaning
T1 T1 T1 temp.
T2 T2 T2 temp.
T3 T3 T3 temp.
T4
T2B T2B temp.
Tb
TP TP temp.
TP
TH
Targeted Frequency Targeted Frequency
Actual Frequency Actual Frequency
Indoor fan speed Indoor fan speed
Outdoor fan speed Outdoor fan speed
EXV opening angle EXV opening angle
Compressor continuous
running time
Compressor continuous
running time
Causes of compressor stop
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Causes of compressor stop
TH temp.
TH
FT
Fr
IF
OF
LA
CT
ST
A0
A1
b1
b0
b2
b3
b4
b5
b6
dL
Ac
Uo
Td
T4 T4 temp.
Press the LED DISPLAY button( Mute button for some
remote controllers) of remote controller three times and then
press AIR DIRECTION button ( Swing button for some
remote controllers) three times within 10 seconds, the buzzer
ring last 2 seconds,the air conditioner will enter the information
enquiry status. After that, press the LED DISPLAY button to
enquiry the next one information and press the AIR
DIRECTION button to enquiry the last one information. When
the air conditioner enter the information enquiry status, it will
display the code name in 2 seconds, the details are as follows:
When the air condtioner enter the information enquiry
status, it will display the code value in the next 25s after
display name is displayed, the details are as follows,
T1,T2,T3,
T4,T2B,TP,
TH,
Targeted
Frequency,
Actual
Frequency
-1F,-1E,
-1d,-1c,
-1b,-1A
-25,-24,-23,-22,
-21,-20
-19-99
0
1,2,3,4
14-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-99
OFF
-19-99
A0,A1...A9 100,101......109
b0,b1...b9
c0,c1....c9
d0,d1...d9
E0,E1...E9
F0,F1...F9
110,111....119
120,121....129
130,131....139
140,141....149
150,151....159
1. All the displaying
temperature is actual
value.
O
2. All the temperature is C
no matter what kind of
remote controller is used.
3. T1,T2,T3,T4,T2B display
range:-25~70, TP display
range:-20~130.
4. Frequency display range:
0~159HZ.
5. If the actual value
exceeds the range, it will
display the maximum
value or minimum value.
Indoor fan
speed/
Outdoor
fan speed
Low speed,
Medium speed,
High speed,
Turbo
For some big capacity
motors.
Actual fan speed
=Display value
turns to decimal
value and then
multiply 10. The
unit is RPM.
For some small capacity
motors, display value is
from 14-FF(hexadecimal),
the corresponding fan
speed range is from
200-2550RPM.
EXV
opening
angle
Actual EXV
opening value=
Display value
turns to decimal
value and then
multiply 2.
Compressor
continuous
running
time
0-255 minutes If the actual value exceeds
the range, it will display the
maximum value or minimum
value.
Causes of
compressor
stop.
For the detailed
meaning, please
consult with
engineer
Decimal display
Other Direct Air Remote Control manuals
Popular Remote Control manuals by other brands

Contro l4
Contro l4 SR-260 Installation and setup guide

Silvercrest
Silvercrest SFB. 10.1 A1 operating manual

K-Rain
K-Rain Pro EX 2.0 Owner's manual and installation instructions

One Remote
One Remote RMB4 user guide

One Forall
One Forall Essence 6 Device manual

One Forall
One Forall URC1912-2 quick start guide

Sunfire
Sunfire OLE-2SF user manual

Paradox
Paradox PRK-315 Reference & installation manual

hisky
hisky X-65 instruction manual

Hobby-Wing
Hobby-Wing Xerun V10 G3R JMRCA user manual

One Forall
One Forall URC 1912 user manual

SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT Z-06 quick start guide