DKS 8040 microplus User manual

120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
Installation Wiegand Access Controller
Connection
Power
DoorKing Part Number
To Receiver Terminal #1 (Neg.)
To Receiver Terminal #2 (Pos.)
12-24 Volt
Transformer
DC Polarity Matters!
Removable receiver
terminal for
easy
wiring.
8040-080
Compatible with
MicroPLUS or MicroCLIK
Transmitters
Separate Power Source: Connect 12 - 24
Volt AC or DC power to terminals #1 and #2.
Use minimum 18 AWG wire to power the receiver.
• If DC power is used (Transformer): Terminal #1
is NEGATIVE and terminal #2 is POSITIVE.
• Power can be supplied to the receiver by the
wiegand access controller instead of a separate
power source.
#1 - Input Power Common (Negative)
#2 - Input Power 12-24 Volt AC, 12-24 Volt DC (Positive)
#3 - Relay N.O. Normally Open
#4 - Relay N.C. Normally Closed
#5 - Relay Common
#6 - Wiegand Common
#7 - Wiegand Data 0
#8 - Wiegand Data 1
(Red Wire)
(Black Wire)
(Green Wire)
(White Wire)
MODEL 8040 MicroPLUS®/ MicroCLIK™ RF RECEIVER
MicroPLUS® Transmitter Codes
MicroCLIK®Transmitter Codes
The 8040 is a High Security Encrypted “Rotating Code” RF Receiver that will output MicroPLUS transmitter codes to a wiegand access controller
in 26, 30 or 31-bit wiegand format.
The 8040 RF receiver will output MicroCLIK transmitter codes to a wiegand access controller in 26, 30 or 31-bit wiegand format.
P/N 8069-080 P/N 8070-080 P/N 8071-080
1Button
2Button
3Button
MicroPLUS Transmitters
12345678
Program LED
Receiver
Terminal
Be sure the
antenna, coax
shield and F
connector are
completely
isolated from
the ground.
F Connector
Wiegand Access Controller Wiring:
Receiver terminal #2 is INPUT POWER (12-24 V).
Receiver terminal #6 is wiegand input power COMMON.
Receiver terminal #7 is wiegand DATA 0.
Receiver terminal #8 is wiegand DATA 1.
Use 22 AWG shielded wire, maximum 200 feet, for wiegand access
controller wiring. Connect these terminals to the corresponding
terminals on the wiegand access controller. Refer a DoorKing wiegand
access controller installation manual for specific wiring information.
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
P/N 8066-080 P/N 8067-080 P/N 8068-080
1Button
2Button
3Button
MicroCLIK Transmitters
This receiver is NOT designed to be installed outdoors
without being protected from the weather. An outdoor
enclosure is available for the receiver if required, (P/N
8057-110 - Metal Outdoor Box).
Install the 8040 receiver in a location so the antenna is NOT
surrounded by metal and is in free air as high as possible
above the ground. A longer Coax Antenna kit is available for
the receiver if required (P/N 1514-073 - Includes antenna,
mounting “L” bracket and 15 feet of coax cable). An antenna
amplifier kit (P/N 8058-080) or a Yagi directional antenna kit
(P/N 1514-072) is also available for the receiver if required.
The Program LED on the side of the case will blink as RF
energy is received. If the program LED blinks or is on
continuously, this indicates that there may be interference on
the frequency (318 MHz) and short range may be the result.
If this happens, try relocating the receiver or remove the
source of interference. An antenna amplifier or a directional
antenna may be needed.
Coax
Antenna
Kit
(Included)
DO NOT use.
26, 30 or 31-Bit
Wiegand Access
Controller connection.
18”
Coax
Cable
The model 8040 RF Receiver is designed for use as a Wiegand RF receiver using either MicroPLUS®or MicroCLIK®
transmitters. A single transmitter can be setup to quickly put the RF receiver into “Learn Mode” to program in additional
transmitter codes. The 8040 receiver current draw may be reduced to about 1 milliampere average for solar gate operator
applications.
A single transmitter MUST be programmed into the receiver’s
memory. Any additional transmitters with the same Facility Code
and Transmitter Button Code will automatically be Learned by the
receiver when it’s button is pressed. The transmitter code will be
output in a wiegand format to the access controller.
A single transmitter MUST be programmed into the receiver’s
memory. Any additional transmitters with the same Facility Code
and Transmitter Button Code will automatically be Learned by the
receiver when it’s button is pressed. The transmitter code will be
output in a wiegand format to the access controller.
Copyright 2014 DoorKing, Inc. All rights reserved.
Note: Receiver has a built-in relay for limited Stand-Alone operations (100 transmitters MAX) using a
normally open or closed access device if desired, see page 3 for more information.
1
8040 065-E-7-14
How Receiver Functions
12345678
Change Mode (MicroPLUSor MicroCLIK)
Check if Receiver is set for MicroPLUS or MicroCLIKMode
1A. Turn the Programming Selector to “Position B” will change to MicroPLUS mode.
1B. Turn the Programming Selector to “Position C” will change to MicroCLIK mode.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once. Press and hold button again, LED will flash
and receiver will beep. Press and hold button a third time until LED continually flashes and beeps.
Note: If receiver does not emit a continuous beep after pressing the button 3 times, try repeating step 2 faster or slower until it does.
3. Turn power OFF, then back ON. Receiver will BEEP twice for MicroCLIK mode (1B) or three times for MicroPLUS mode (1A).
1A. Turn the Programming Selector to “Position 2” will change to 26-Bit Wiegand (Factory Setting).
1B. Turn the Programming Selector to “Position 3” will change to 31-Bit Wiegand.
1C. Turn the Programming Selector to “Position 4” will change to 30-Bit Wiegand.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver is now changed to “Your Selected Wiegand Bit Size Chosen in Step 1”.
1. Turn receiver’s power OFF then back ON.
2. Receiver will BEEP twice for MicroCLIK mode. Receiver will BEEP three times for MicroPLUS mode (Factory Setting).
If you need to change the receiver’s mode, follow the steps below.
CAUTION: Changing an EXISTING programmed receiver from one mode to the other will erase ALL EXISTING MEMORY that has been previously
programmed in the receiver. This cannot be UNDONE.
Programming Selector’s 11 positions:
1. Learn Single Transmitter
2. 26-bit Wiegand Mode (Factory Setting)
3. 31-bit Wiegand Mode
4. 30-bit Wiegand Mode
5. Match Facility Code
6. Ignore Facility Code (Factory Setting)
7. Not Used
8. Low-Power Mode (Stand-Alone Setup ONLY)
9. Normal-Power Mode (Factory Setting)
A. Erase ALL Memory
B. Set Receiver to MicroPLUS Mode (Factory Setting)
C. Set Receiver to MicroCLIK Mode
D-F. Not Used
Wiegand LED’s: Will blink
as wiegand data is being
transmitted.
Program LED: Will flash
sequences during
programming and
flashes during normal
operation or frequency
interference.
The 8040 receiver responds to the MicroPLUS or MicroCLIK transmitter’s “Transmitter
Code” that is defined by “Transmitter Button Codes” and “Facility Codes”. For
example: an 8040 receiver can be programmed to respond to only the first button on a
multiple button MicroPLUS or MicroCLIK transmitter while a second 8040 receiver
can be programmed to respond to only the second button of the same multiple
button MicroPLUS or MicroCLIK transmitter. Thus allowing a single multiple button
MicroPLUS or MicroCLIK transmitter to activate two different receivers without
fear of both receivers responding to the same transmitter code.
In wiegand output mode (Program selector setting 2, 3 or 4), you have the option of
having the receiver match (Program selector setting 5) or ignore (Program selector
setting 6) the facility code to allow the receiver to activate. One receiver can be
programmed to respond to a specific facility code while another receiver can be programmed
for a different facility code.
Program Button
Program
Selector
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Learn a Single Transmitter for Wiegand Output
26, 30 or 31-Bit Wiegand Output
1. Turn the Programming Selector to Position 1.
2. Press and HOLD Program Button until the Program LED flashes ONCE and receiver will BEEP once. Receiver is now in “Learn Mode” and will
flash and beep for 10 seconds.
3. Press a specific button on the desired transmitter to be “Learned” within 10 seconds, wait for the receiver to time-out.
All desired transmitters with matching facility/button codes will now operate when their button is pressed.
Only a single transmitter needs to be programmed (Learned) into the receiver memory. All other transmitters that match the Learned transmitter’s
Facility Code and Transmitter Button Code will be output in wiegand format to the access controller.
Important: This programming is for wiegand output to an access controller ONLY and will NOT work when using the Stand-Alone setup (Relay
connection). Low power mode can only be used in Stand-Alone setup.
The receiver can be changed from the factory set 26-Bit to 30 or 31-Bit wiegand output if desired.
2
8040 065-E-7-14
Match or Ignore Facility Code
Change to LOW -Power Mode
1. Turn the Programming Selector to Position 8.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver will be put into LOW-Power mode which consumes LESS power than NORMAL-Power mode.
The receiver can be changed from normal-power to LOW-Power mode. LOW-power mode is used in DoorKing solar gate operator applications.
Wiegand output will NOT work in LOW-Power mode.
NORMAL -Power Mode (Factory Set)
1. Turn the Programming Selector to Position 9.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver will be put into NORMAL-Power mode which consumes MORE power than LOW-Power mode.
The receiver comes from the factory already set in NORMAL-Power mode. It can be changed from LOW-Power back to NORMAL-Power mode.
The receiver contains a built-in relay that can operate an access device such as a gate operator or door lock. Connect receiver terminals #3 and #5
to a normally open access device or terminals #4 and #5 to a normally closed access device. The memory of the receiver can ONLY store 100
MicroPLUS or MicroCLIK transmitters MAXIMUM. The relay will activate when the correct Facility Code and Transmitter Button Code match the
codes that have been stored in the memory from a single transmitter (Learned).
Erase ALL Memory - This CANNOT be UNDONE
STAND-ALONE RECEIVER SETUP - RELAY CONNECTION
1. Turn the Programming Selector to Position A.
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once. Press and hold button again, LED will flash
and receiver will beep again. Press and hold button a third time, LED will flash and receiver will beep a third time.
3. The receiver will then emit a long flash and long beep indicating ALL memory, including master transmitters have been erased from memory.
Note: If receiver does not emit a continuous beep after pressing the button 3 times, try repeating step 2 faster or slower until it does.
1A. Turn the Programming Selector to “Position 5” will MATCH the Learned transmitter’s facility code.
1B. Turn the Programming Selector to “Position 6” will IGNORE the Learned transmitter’s facility code (Factory Setting).
2. Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3. Receiver LED will then give a long flash and beep.
4. This indicates receiver is now changed to “Your Selection in Step 1”.
The receiver can be programmed to MATCH or IGNORE the Learned transmitter’s facility code.
Access Device Relay
Connection
12345678
Receiver
Terminal
Be sure the
antenna, coax
shield and F
connector are
completely
isolated from
the ground.
F Connector
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Coax
Antenna
Kit
(Included)
18”
Coax
Cable
Programming Selector’s 8 positions that can be used:
1. Learn Transmitters (See below)
5. Match Facility Code
6. Ignore Facility Code (Factory Setting)
8. Low-Power Mode (Stand-Alone Setup ONLY)
9. Normal-Power Mode (Factory Setting)
A. Erase ALL Memory
B. Set Receiver to MicroPLUS Mode (Factory Setting)
C. Set Receiver to MicroCLIK Mode
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1. Turn the Programming Selector to Position 1.
2. Press and HOLD Program Button until the Program LED flashes ONCE and
receiver will BEEP once. Receiver is now in “Learn Mode” and will flash and
beep every second for 10 seconds.
3. Press a specific button on the desired transmitter to be “Learned” within
10 seconds. Receiver will reset 10 second timer after each transmitter button
has been pressed.
4. Press other desired transmitter buttons to be learned, each within 10 seconds.
5. After all desired transmitters have been learned by the receiver, wait 10
seconds for the receiver to time-out and end programming.
DO NOT Use.
#1 - Input Power Common (Negative)
#2 - Input Power 12-24 Volt AC, 12-24 Volt DC (Positive)
#3 - Relay N.O. Normally Open
#4 - Relay N.C. Normally Closed
#5 - Relay Common
#6 - Wiegand Common
#7 - Wiegand Data 0
#8- Wiegand Data 1
Learn Up to 100 Transmitters
Program LED Program Button
3
8040 065-E-7-14

This manual suits for next models

1

Other DKS Receiver manuals

DKS MicroPLUS 8055 User manual

DKS

DKS MicroPLUS 8055 User manual

DKS 8057 Installation guide

DKS

DKS 8057 Installation guide

DKS 8040 microplus User manual

DKS

DKS 8040 microplus User manual

Popular Receiver manuals by other brands

Univers by FTE U5000 user manual

Univers by FTE

Univers by FTE U5000 user manual

KEC LSMD-121 Installation information & operating instructions

KEC

KEC LSMD-121 Installation information & operating instructions

SECO-LARM Enforcer SK-910R Series quick start guide

SECO-LARM

SECO-LARM Enforcer SK-910R Series quick start guide

Pyle PT696BT user manual

Pyle

Pyle PT696BT user manual

AIRTRONICS M11 operating manual

AIRTRONICS

AIRTRONICS M11 operating manual

Dension DAB+A Installation and user manual

Dension

Dension DAB+A Installation and user manual

T+A K2 M manual

T+A

T+A K2 M manual

Samsung HT-AS720S instruction manual

Samsung

Samsung HT-AS720S instruction manual

Inovonics INOmini 673 Installation & user guide

Inovonics

Inovonics INOmini 673 Installation & user guide

Microzone MC7RB-V2 product manual

Microzone

Microzone MC7RB-V2 product manual

Bellman & Symfon Visit user manual

Bellman & Symfon

Bellman & Symfon Visit user manual

Venstar T1100REC installation instructions

Venstar

Venstar T1100REC installation instructions

Vicon V702R-R Installation and operation manual

Vicon

Vicon V702R-R Installation and operation manual

Phonak Dynamic SoundField DigiMaster X installation instructions

Phonak

Phonak Dynamic SoundField DigiMaster X installation instructions

FaVal Aquila T 200 user manual

FaVal

FaVal Aquila T 200 user manual

Pioneer SC-LX82 Service manual

Pioneer

Pioneer SC-LX82 Service manual

Denver DVBT-1 user manual

Denver

Denver DVBT-1 user manual

Lars Thrane LT-300 Product sheet

Lars Thrane

Lars Thrane LT-300 Product sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.