Dnake A416 User manual

Model: 280SD-C12
280SD-R2
280SD-R5
Quick Start Quide
Door Station
The picture is only a schematic diagram. The actual product shall prevail.
USER MANUAL
A416

Please follow the user manual for correct installation and
testing. If there is any doubt please call our tech-supporting
and customer center.
Our company applies ourselves to reformation and
innovation of our products. No extra notice for any change.
The illustration shown here is only for reference. If there is
any difference, please take the actual product as the
standard.
The product and batteries must be handled separately from
household waste. When the product reaches the end of
service life and needs to be discarded, please contact the
local administrative department and put it in the designated
collection points in order to avoid the damage to the
environment and human health caused by any disposal. We
encourage recycling and reusing the material resources.
REMARK

CATALOG
Product Features .....................................................1
Technical Parameters .............................................1
Package Contents...................................................2
Pictures.....................................................................2
Operations ...............................................................3
Web Settings..........................................................21
System Configuration ..........................................25
System Diagram ...................................................26
Installation .............................................................28
Troubleshooting ...................................................30
Safety Instructions ................................................31

PRODUCT FEATURES
1. Building intercom application:
Talkback: Support video call, monitoring, unlocking, and checking of
call records.
Security: Support 8 alarm zones with three states, zone and scene
setup.
Smart: Support smart home extension by RS485 communication.
2. Operating system: Android.
TECHNICAL PARAMETERS
Voltage: DC 12V
POE
Rated power: 10W
Standby power consumption: 3W
Display screen: 7-inch IPS LCD
Touch screen: Capacitive touch screen
Resolution: 1024x600
Working Temperature: -10℃ to +55℃
Storage Temperature: -10℃ to +60℃
Working Humidity: 10% to 90% (non-condensing)
1

Package Contents
MODEL: A416
Please make sure the package contains the following items:
PACKAGE CONTENTS
2
PICTURES
:
Quick Start Guide
Screw
Indoor Monitor Bracket
Speaker
7'' capacitive
touch screen
Camera
Microphone

3
OPERATIONS
Main menu: Call, Monitor, Camera, Phonebook, Message, DND, QR Code,
Security, Security, Concierge, Lift Control, SOS, Settings.
Click “Call” icon on the main interface, the system will enter the following
interface:
1.Call

1.1 Call Logs
Click “Call Logs” icon, the system will enter the following interface:
refers to call-out record; refers to call-in record; refers to missed
call record. It can save up to 60 records.
Select one record and click icon to call; click icon to delete it.
If there is any snapshot image, click icon to view it.
1.2 Dial
Click “Dial” icon, the system will enter the following interface:
1.2.1 Call Resident
Input 1-3 digits building No.+ “Building” + 2-digit Unit No. + “Riser” +4-digit
room No., then click icon to call.
The system will enter into the following interface:
4

When the call is answered, the system will enter into call state:
1. If there is a camera, the caller’s image will be displayed on the screen;
2. When the call is answered, the video will be uploaded into the indoor
monitor.
5
click icon to end the call.
You can make audio and video recording during communication (TF card
should be inserted into indoor monitor ). Click icon to take a snapshot;
click icon to save the video and image for current communication.
The system’s default call duration is 120s.
1.2.2 Call Master Station
Click “ ” icon to call master station, the system will call master station
No.1-No.5 successively. If the master station cannot be searched or call
failed, the system will automatically call next master station. When the
master station answers, it will ring and stop calling next one.
Click icon to end the communication.
When calling, the indoor monitor will ring; if there is no answer within 25
seconds, the call will be ended.
1.2.2 Door station call
Clicking “ ” icon to call management center(namely master station),
the system will call management center No.1-No.5 successively. If the
management center cannot be searched or call failed, the system will
automatically call next management center. When the management center
answers, it will ring and stop calling next one.
Click icon to end the communication.

1.3 Phonebook
Click “Phonebook” icon, the system will enter the following interface:
6
1.2.3 Receive Call from Door Station
When the door station, wall station or secondary door station calls, the
indoor monitor will ring; when door station calls indoor monitor, the image
from door station will be displayed on the indoor monitor; if there is no
answer within 25 seconds, the call will be ended.
click icon to end the call; click icon to unlock the door.
Remark: Click icon to switch between answering interface and
monitoring interface of IP camera. After numeric keypad shows, press
number key "2" to "9" to select the IP camera and press "1" to return to
previous page.
You can make audio and video recording during communication (TF card
should be inserted into indoor monitor ). Click icon to take a snapshot of
the visitor; click icon to save the video and image for current
communication.
The system’s default call duration is 120s.

Click “ ” icon to search for the contact. Click “ ” icon to edit and save
the contact
Click “Monitor” icon on the main interface, the system will enter the
following interface:
2.Monitor
Click “Door01” icon to switch the type of door station, then click or icon
to select the area you want to monitor. Click icon to end monitoring. Click
icon to unlock the door.
Remark: The system’s default monitoring time is 25s.
7

Click “Camera” icon on the main interface, the system will enter the
following interface:
3.Camera
Click “ ” or “ ” button to select the camera. To cancel monitoring, click
to stop it.
2.2.1 IP Camera Setting
Login the webpage of indoor monitor by username: user, password:1234, to
access the following webpage:
8

Fill in with the RTSP format: rtsp:// user: password@ Camera IP, which may
differ because of the manufacturer. IP is the IP address of your IP Camera.
Then you can monitor IP Camera on your indoor monitor.
Click “Message” icon on the main interface, the system will enter the
following interface:
4.Message
Note: Indoor monitor can only receive the message sent by the
management software installed on the computer which is usually located
at guard center.
Up to 64 records can be received in SMS.
Click “QR Code” icon on the main interface, the system will enter the
following interface:
5.QR Code
Scanning the QR code with DNAKE Smart Life APP, it will be synchronized
with the indoor monitor.
9

Click “Security” icon on the main interface, the system will enter the
following interface:
6.Security
6.1 ON/OFF
Click “ON/OFF” icon, the system will enter into the following interface:
6.1.1 ON
Click “Out”, “Home”, or “Sleep” icon to activate the alarm sensors, the icon
on the main interface will light up with a beep and stay lit.
6.1.2 OFF
(1) During delay time of the alarm, click “OFF” icon, the system will beep to
distable the alarm.
(2) Input user password(the default password is 1234) to disable the alarm
under alarm ON status.
10

6.2 Zone
Remark: the settings should be made when alarm is OFF.
Click “Zone” icon and input 1-16 digits password(the default password is
1234), the system will enter into the following interface:
6.2.1 Alarm Type
Click Type, it will show as the following. In this interface, you can set alarm
Type as: Normal, Emergency or 24H. 24H and Emergency types are always
active.
6.2.2 Mode
Click mode, it will show the following interface. In this interface, you can
set mode as: 3C, NO, NC or BELL.
11

6.2.3 Delay Time
It refers to the delay time of giving an alarm. Click Delay setting, it will
show the following interface with selections: 0s, 5s, 15s, 20s, 25s, 40s or 60s
as the desired delay time. For example, select the delay time: 5s. Once the
alarm sensor is triggered, the indoor monitor will issue the sirens after 5
seconds.
6.2.4 Sensor Type
Click sensor type, it will show the following interface. Each sensor type can
be set up as: Smoke, Gas, PIR, Door, Window, Panic, Flood, Pull Cord.
12

6.3 Scene
Click “Scene” icon, the system will enter into the following interface:
refers to Alarm ON, refers to Alarm OFF. To set the sensor of alarm
stations, you can click the corresponding station with icon. Click
"Activation Time" to select the corresponding time. The options of
activation time include NONE, 30s, 40s, 60s, 100s and 300s.
13

6.4 Settings
Click “Settings” icon, the system will enter into the following interface:
You can set the new system password with 1-16 digits (the default
password is 123456). System password is used for system settings.
Click “Concierge” icon on the main interface, the system will enter the
following interface:
7.Concierge
Call the master station directly.
Click “Lift Control” icon on the main interface, the system will enter the
following interface:
8.Lift Control
14

Click or icon to summon the elevator to go up and down. Click
“Permit” icon to allow access to the floor where the indoor monitor is
located.
Remark: To support this function, your system must connect with “Elevator
Control” module. Kindly check with your system provider.
This function allows making an emergency call to master station with one
button.
9.SOS
10.Settings
Click “Settings” icon on the main interface, the system will enter the
following interface:
10.1 Display
“Brightness level” and “Sleep” mode time can be set.
15

10.2 Sounds
Click “Sounds” icon, the system will enter into the following interface:
“Auto Answer”, “Ring Vol”, “Intercom Vol” and "Ringtone" can be set.
10.3 Date & Time
Click “Date & Time” icon, the system will enter into the following interface:
This interface can set “Automatic date & time”, “Time Zone”, “12H/24H” and
“NTP”.
10.4 Language
Click “Language” icon, the system will enter into the following interface:
16

The system language can be switched.
10.5 Version
Click “Version” icon, the system will enter into the following interface:
This interface can view “FW”, “IP”, “WiFi IP” and “MAC”.
10.6.1 Ethernet
Click “Ethernet” icon, the system will enter into the following interface:
10.6 More
Click “More” icon, then input 1-16 digits password (the default password is
123456 ) to make the following settings:
17
Other manuals for A416
1
Table of contents
Other Dnake Monitor manuals