A. CONNECTING THE GTP-32 UNIT TO THE BREAKOUT PANEL.
Look at the back of the GTP-32 unit and note the legend under the 37 pin I/O connectors. The breakout panel
has two sets of 37 pin connectors, one set is labeled GPI & GPO and the other set is labeled GPIO. Connect the
furnished 37 pin interconnect cable to the matching connector on the breakout panel and the GTP-32 unit.
Connect all 4 cables to their respective connectors.
Example 1:
Legend on GTP-32 unit = GPOI 1-8; connect to GPOI 1-8 connector on breakout panel.
Legend on GTP-32 unit = GPOI 9-16; connect to GPOI 9-16 connector on breakout panel
Legend on GTP-32 unit = GPOI 17-24; connect to GPOI 17-24 connector on breakout panel.
Legend on GTP-32 unit = GPOI 25-32; connect to GPOI 25-32 connector on breakout panel
Example 2:
Legend on GTP-32 unit = GPI 1-16; connect to GPI 1-16 connector on breakout panel.
Legend on GTP-32 unit = GPI 17-32; connect to GPI 17-32 connector on breakout panel
Legend on GTP-32 unit = GPO 1-16; connect to GPO 1-16 connector on breakout panel.
Legend on GTP-32 unit = GPO 17-32; connect to GPO 17-32 connector on breakout panel
B. CONNECTING THE EXTERNAL INPUTS AND OUTPUTS
1) PHOENIX TWO PIN CONNECTORS.
Each GPI and each GPO has its own 2 pin connector. The GPOs are on the top row and the GPIs are on
the bottom row. Each GPI and GPO may be configured for Wet or Dry mode using jumpers below the
phoenix connector. When using the WET mode, only use a switch closure across the pins.
2) SET GPI WET/DRY MODE
Configure Wet/Dry mode for each individual GPI using the jumpers below the GPI connector. The DRY
mode uses only one jumper across the two center pins (D). The wet mode uses two jumpers across the
two outside pins (WW).
3) SET GPO WET/DRY MODE
Page 2 of 5
G
GT
TP
P-
-3
32
2-
-B
BP
P
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
G
Gu
ui
id
de
e

Configure Wet/Dry mode for each individual GPO using the jumpers below the GPO connector. The DRY
mode uses only one jumper across the two center pins (D). The wet mode uses two jumpers across the
two outside pins (WW).
C. GPI/GPO CONNECTOR PINOUT
DRY MODE = DNF DOES NOT PROVIDE POWER
WET MODE = DNF PROVIDES POWER
1) GPI CONNECTOR
Dry Mode:
Pin #1: Anode ( + )
Pin #2: Cathode ( - )
Wet Mode:
Pin #1: Cathode ( - )
Pin #2: Ground
2) GPO CONNECTOR
Dry Mode:
Pin #1: N.O.
Pin #2: Relay Common
Wet Mode:
Pin #1: N.O.
Pin #2: Ground
Pin #2: Ground
D. CONNECTING TO A USP3-8/AIB-2 USING ADAPTOR BOARDS
When connecting a USP3-8 or AIB-2 to a GTP-32 breakout panel the use of a adaptor board is required. The
adaptor board connectors are as follow:
J1 Connector DB25 GPIO 1-8
J2 Connector DB25 GPIO 9-16
J3 Connector DB37 GPIO 1-16
GPI CONNECTION
1) Using a DB25 cable, connect one end of the cable into the GPO 1-8 port of the USP/AIB.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Connect the adaptor board into the DB37 GPI 1-16 connector on the GTP-32 breakout panel.
GPO CONNECTION
1) Using a DB25 cable, connect one end of the cable into the GPI 1-8 port of the USP/AIB.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Connect the adaptor board into the DB37 GPO 1-16 connector on the GTP-32 breakout panel.
Page 3 of 5
G
GT
TP
P-
-3
32
2-
-B
BP
P
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
G
Gu
ui
id
de
e

E. CONNECTING TO A USP3-16/AIB-3/AIB-4 USING ADAPTOR BOARDS
When connecting a USP3-16, AIB-3 or AIB-4 to a GTP-32 breakout panel the use of a adaptor board is required.
The adaptor board connectors are as follow:
J1 Connector DB25 GPIO 1-8
J2 Connector DB25 GPIO 9-16
J3 Connector DB37 GPIO 1-16
GPI CONNECTION
1) Using a DB25 cable, connect one end of the cable into the GPO 1-8 port of the USP/AIB.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Using a second DB25 cable, connect one end of the cable into the GPO 9-16 port of the USP/AIB.
4) Connect the other side of the DB25 cable into the J2 connector of the adaptor board.
5) Connect the adaptor board into the DB37 GPI 1-16 connector on the GTP-32 breakout panel.
GPO CONNECTION
1) Using a DB25 cable, connect one end of the cable into the GPI 1-8 port of the USP/AIB.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Using a second DB25 cable, connect one end of the cable into the GPI 9-16 port of the USP/AIB.
4) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
5) Connect the adaptor board into the DB37 GPO 1-16 connector on the GTP-32 breakout panel.
F. CONNECTING MULTIPLE USP3-16’S/AIB-3’S/AIB-4’S USING ADAPTOR BOARDS
When connecting multiple USP3-16’s, AIB-3’s or AIB-4’s to a GTP-32 breakout panel the use of a adaptor board
is required. The adaptor board connectors are as follow:
J1 Connector DB25 GPIO 1-8
J2 Connector DB25 GPIO 9-16
J3 Connector DB37 GPIO 1-16
GPI CONNECTION
1st USP/AIB PANEL
1) Using a DB25 cable, connect one end of the cable into the GPO 1-8 port of the first USP/AIB panel.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Using a second DB25 cable, connect one end of the cable into the GPO 9-16 port of the first USP/AIB
panel.
4) Connect the other side of the DB25 cable into the J2 connector of the adaptor board.
5) Connect the adaptor board into the DB37 GPI 1-16 connector on the GTP-32 breakout panel.
2nd USP/AIB PANEL
1) Using a DB25 cable, connect one end of the cable into the GPO 1-8 port of the second USP/AIB panel.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Using a second DB25 cable, connect one end of the cable into the GPO 9-16 port of the second USP/AIB
panel.
4) Connect the other side of the DB25 cable into the J2 connector of the adaptor board.
5) Connect the adaptor board into the DB37 GPI 17-32 connector on the GTP-32 breakout panel.
Page 4 of 5
G
GT
TP
P-
-3
32
2-
-B
BP
P
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
G
Gu
ui
id
de
e

GPO CONNECTION
1st USP/AIB PANEL
1) Using a DB25 cable, connect one end of the cable into the GPI 1-8 port of the first USP/AIB panel.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Using a second DB25 cable, connect one end of the cable into the GPI 9-16 port of the first USP/AIB
panel.
4) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
5) Connect the adaptor board into the DB37 GPO 1-16 connector on the GTP-32 breakout panel.
2nd USP/AIB PANEL
1) Using a DB25 cable, connect one end of the cable into the GPI 1-8 port of the second USP/AIB panel.
2) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
3) Using a second DB25 cable, connect one end of the cable into the GPI 9-16 port of the second USP/AIB
panel.
4) Connect the other side of the DB25 cable into the J1 connector of the adaptor board.
5) Connect the adaptor board into the DB37 GPO 17-32 connector on the GTP-32 breakout panel.
Page 5 of 5
G
GT
TP
P-
-3
32
2-
-B
BP
P
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
G
Gu
ui
id
de
e
Table of contents
Popular I/O System manuals by other brands

Measurement Computing
Measurement Computing USB-1208HS user guide

Numatics
Numatics 580 Installation and maintenance instructions

M-system
M-system R3-SV16N instruction manual

National Instruments
National Instruments DAQ M Series user manual

Festo
Festo CPX Series manual

National Instruments
National Instruments PCI-6154 Note to Users

MG
MG Mini-M M2VV instruction manual

DAQ
DAQ DAQCard-1200 user manual

National Instruments
National Instruments PXIe-5764 SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

Allen-Bradley
Allen-Bradley ArmorBlock MaXum 4 installation instructions

Tews Technologies
Tews Technologies TPMC160 user manual

Artistic License
Artistic License vSplit mono xlr8-8 user guide