Dometic Comfort Control Center 2 Thermostat Quick Start-Up
The basic steps for operating your Air Conditioner, Heat Pump or Dehumidier (herein
after referred to as the “unit”), are described in this User’s Guide. For more detailed
information on modes of operation and special features refer to the Operating Instruc-
tions Manual.
Quick reference to control buttons
Press to display
inside temperature
Press to select
temperature format
Press to decrease
temperature or
humidity set-point
Press to increase temperature
or humidity set-point
Press to display
relative humidity set-
point (Select Models)
Press to select zone
Press to select
On and OFF
Press to select fan
speed
Press to set
clock
Press to
select mode
Press to select
program 1 or 2
REVISION
Form No. 3314150.016 10/11
(Replaces 3314150.000)
(French 3314170.014)
©2011 Dometic, LLC
LaGrange, IN 46761
3314150.016
1. To turn ON the CCC 2 thermostat
when the back light is off, rst press
any button to wake up the CCC 2
thermostat. Then press and release
the ON/OFF button.
2. Press the MODE button to cycle
through the mode options. A mode is
an operation that can be performed
by the unit and is controlled by
the Dometic CCC thermostat. The
available modes are: OFF, COOL,
HP (HEAT PUMP), HS (Heat Strip),
FAN, FURN (Furnace), and AUTO.
The available modes are determined
by your system options.
3. Press the ZONE button to cycle
through the available zones to be
programmed. Each zone signies a
unit designated to cool, heat or de-
humidify a specic area of an RV.
The Dometic CCC 2 thermostat can
control up to four units (zones).
4. Press the UP or DOWN but-
tons to increase or decrease the room
air temperature (hereinafter referred
to as the set-point). The set-point
is the desired inside room air tem-
perature.
5. Press the FAN button to select the
fan speed. The options are AUTO, HI,
MED, or LO.
7. Press and hold the INSIDE TEMP
button and the LCD will display the
current inside temperature recorded
at the CCC 2 Thermostat (or at the
optional remote indoor temperature
sensor) instead of the temperature
set-point. The LCD will also display
“IN” to indicate that the inside tem-
perature is being displayed. When the
INSIDE TEMP button is released, the
LCD will return to the programmed
temperature set-point.
6. Press the CLOCK button to initiate
the clock setting sub-menu on the
CCC 2 thermostat. When entering
this menu, the “hour” digits will ash
rst. Press the CLOCK button again
and the “minutes” digits will ash.
Press it a third time and the “AM” or
“PM” icon will ash.
Press the UP and DOWN but-
tons to set the “hour”, “minute”, and
“AM/PM” setting.
Press the CLOCK button one more
time to store the new time in memory
and exit the clock setting sub-menu.
E3 Shorted Indoor Temperature Sensor.
All heat, cool, and dehumidify opera-
tion will be locked out. Manual fan op-
eration can continue.
E4 Open circuit or out of range Outdoor
Temperature Sensor (Select Models).
Heat pump and dehumidication op-
eration will be locked out. Air condi-
tioner, furnace, heat strip, and fan op-
eration can continue to operate.
E5 Open circuit or out of range Freeze
Sensor (Select Models). Air condition-
er and dehumidication operation will
be locked out. Heat pump, furnace,
heat strip, and fan operation can con-
tinue to operate but displays the last
temperature set-point.
E6 Open circuit Humidity Sensor (Select
Models). Air conditioner and dehu-
midication operation will be locked
out. Heat pump, furnace, heat strip,
and fan can continue to operate.
E7 Loss of 120 VAC power to all power
module boards on the system. The
system will shut down.
E8 Invalid zone conguration. The heat
pump and heat strip DIP switches
are both set to the ON position in one
zone. Heat pump, heat strip, air con-
ditioner, and dehumidify operation
will be locked out in the affected zone.
E9 Invalid zone conguration. The dehu-
midier DIP switch and either the heat
pump or heat strip DIP switches are
set to the ON position in one zone.
Heat pump, heat strip, air condition-
er, and dehumidify operation will be
locked out in the affected zone.
In the unlikely event you experience a system failure, refer to the “SERVICE” section of the Operating
Instructions furnished with your unit.
Special Features:
●Auto Fan
● Stage Select (Two air conditioners/
heat pumps or models equipped with
two compressors)
●Programs 1 & 2
● Auxiliary Heat (heat pump models
only)
●Load Shed
● Automatic Generator Start (optional)
See Operating Instructions Manual
for more information on special fea-
ture.
LCD Error Code
When the system determines that one of
the faults listed below has occurred an
error code will be displayed in the LCD
for the zone in which the error occurred.
During normal operation, a blinking zone
number indicates a fault has occurred.
The error code is displayed in place of the
temperature set-point.
Error Code:
E1 Loss of communication between the
CCC 2 thermostat and all system
power module boards. System will
shut down.
E1 Loss of communication between the
CCC 2 thermostat and an individual
system power module board. The
LED will display error code E1 and
the zone number that lost communi-
cation. Any additional zones that lose
communication will blink in addition to
the current zone.
E2 Open circuit or out-of-range Indoor
Temperature Sensor. All heat, cool,
and dehumidify operation will be
locked out. Manual fan operation can
continue.

Other Dometic Thermostat manuals

Dometic 3316420 Series User manual

Dometic

Dometic 3316420 Series User manual

Dometic 3312026 series User manual

Dometic

Dometic 3312026 series User manual

Dometic Comfort Control Center 2 User manual

Dometic

Dometic Comfort Control Center 2 User manual

Dometic 3314081.XXX User manual

Dometic

Dometic 3314081.XXX User manual

Dometic 3313192 Series User manual

Dometic

Dometic 3313192 Series User manual

Dometic Single Zone LCD Thermostat User manual

Dometic

Dometic Single Zone LCD Thermostat User manual

Dometic 3312026.XXX User manual

Dometic

Dometic 3312026.XXX User manual

Dometic 3316462.000 User manual

Dometic

Dometic 3316462.000 User manual

Dometic 3314080.000 BLACK User manual

Dometic

Dometic 3314080.000 BLACK User manual

Popular Thermostat manuals by other brands

Habitat HTE-01 Programming guide

Habitat

Habitat HTE-01 Programming guide

Johnson Controls T9500 owner's manual

Johnson Controls

Johnson Controls T9500 owner's manual

ensto eVahti Operation & installation instructions

ensto

ensto eVahti Operation & installation instructions

Honeywell Tradeline T8024D Product data

Honeywell

Honeywell Tradeline T8024D Product data

Lightstat e-stat Hardware installation and operation manual

Lightstat

Lightstat e-stat Hardware installation and operation manual

Hugo Müller GS 10.00 PRO instruction manual

Hugo Müller

Hugo Müller GS 10.00 PRO instruction manual

Honeywell Tradeline Chronotherm IV installation instructions

Honeywell

Honeywell Tradeline Chronotherm IV installation instructions

GE RAK160W2 Owner's Manual & Installation Instructions

GE

GE RAK160W2 Owner's Manual & Installation Instructions

Powerley Powerley Thermostat Installation & operation guide

Powerley

Powerley Powerley Thermostat Installation & operation guide

Ingersoll-Rand TRANE NEXIA TZEMT500BB32MAA Installation and user instructions

Ingersoll-Rand

Ingersoll-Rand TRANE NEXIA TZEMT500BB32MAA Installation and user instructions

Perfect Sence PS2110 Series owner's manual

Perfect Sence

Perfect Sence PS2110 Series owner's manual

Giacomini K470H quick start guide

Giacomini

Giacomini K470H quick start guide

ClimateMaster ATA32V01 Owner's Manual & Installation Instructions

ClimateMaster

ClimateMaster ATA32V01 Owner's Manual & Installation Instructions

Warmup tempo operating guide

Warmup

Warmup tempo operating guide

Salus ST880ZB installation guide

Salus

Salus ST880ZB installation guide

Grohe 34 123 quick start guide

Grohe

Grohe 34 123 quick start guide

Honeywell Home RLV3120 owner's manual

Honeywell Home

Honeywell Home RLV3120 owner's manual

HBX THM-0500 installation manual

HBX

HBX THM-0500 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.