Stand-Alone Power and Device Wiring : Connect 12 - 24 Volt AC or DC power to
terminals #1 and #2. Use minimum 18 AWG wire to power the receiver.
• If DC power is used (Transformer): Terminal #1 is NEGATIVE and Terminal #2 is POSITIVE.
• Connect the receiver relay contacts to the device to be activated.
- Receiver Terminal #3 is the relay contact Normally OPEN (N.O.)
- Receiver Terminal #4 is the relay contact Normally CLOSED (N.C.)
- Receiver Terminal #5 is the relay contact Common (C).
MODEL 8057 MicroCLIK™RF RECEIVER
Installation
Receiver Terminal Wiring
DoorKing Part Numbers
The model 8057 RF Receiver is designed for use with MicroCLIK™ transmitters. The receiver can store 10 facility codes and 50 to
16,000 unique transmitter codes depending on the model selected. It is also programmed to recognize only certain transmitter
buttons.
The 8057 has a built in programming keypad allowing transmitter codes to be block coded or individually added/deleted to its
memory. It is a stand alone receiver that activates a built-in dry contact form “C” relay when a programmed transmitter code is
received. The received code MUST match the programmed “Facility Code”, “Transmitter Code”, and “Transmitter Button Code”
before the receiver relay will activate.
The MicroCLIK™ system is compatible with
the HomeLink system found in many
automobiles.
This receiver is NOT designed to be installed outdoors without being protected from the weather. An outdoor enclosure is available for the receiver
if required (P/N 8057-110 - Metal Outdoor Box).
Install the 8057 receiver in a location so the antenna is NOT surrounded by metal and is in free air as high as possible above the ground.
A longer Coax Antenna kit is available for the receiver if required (P/N 1514-073 - Includes antenna, mounting “L” bracket and 15 feet of coax
cable).
The RF LED on the side of the case will blink as RF energy is received. If the LED blinks or is on continuously, this indicates that there may be
interference on the frequency (318 MHz) and short range may be the result. If this happens, try relocating the receiver or remove the source of
interference.
Note: Loop detectors and proximity card readers can cause receiver interference.
To Receiver Terminal #1 (Neg.)
To Receiver Terminal #2 (Pos.)
12-24 Volt
Transformer
P/N 8066-080 P/N 8067-080 P/N 8068-080
From “Low Voltage Common”
From “Radio Open”
From “Circuit Board” Power
1 Button
2 Button
3 Button
MicroCLIK™ Transmitters
Gate Operator: Connect the
3 wires from the gate operator
as indicated.
To Receiver Terminal #1
To Receiver Terminal #2
To Receiver Terminal #3
DC Polarity Matters!
Removable receiver
terminal for easy wiring.
8057-081
50 Transmitter Codes
8057-082
100 Transmitter Codes
8057-083
250 Transmitter Codes
8057-084
500 Transmitter Codes
8057-085
1000 Transmitter Codes
8057-086
5000 Transmitter Codes
8057-088
16,000 Transmitter Codes
F Connector
Coax Antenna Kit
(Included)
18” Coax Cable
3
2
1
6
5
4
9
8
7
#
0
*
8
7
0
*
9
#
2
13
5
46
Master Code Button
(See next page)
12345678
Receiver
Terminal
RF LED
#1 - Input Power 12-24 Volt AC, 12-24 Volt DC (Negative)
#2 - Input Power 12-24 Volt AC, 12-24 Volt DC (Positive)
#3 - Relay Contact (Normally Open)
#4 - Relay Contact (Normally Closed)
#5 - Relay Contact (Common)
#6-8 - Not Used
Terminals 3-4-5
rated for 30 volt,
1 amp max.
120 S. Glasgow Avenue
In
g
lewood
,
California 90301 U.S.A.
Programming
Program the Master Code: The master code is the four-digit number required to gain access to the
receiver memory for all programming. You MUST program a MASTER CODE first.
1st Digit 2nd Digit 3rd Digit 4th Digit
Write Down Your Master Code
? ? ? ?
any four numbers
then press “BEEP”
2. Choose and enter four-digits on the keypad
1. Press Master Code Button
Important Note: Keep this instruction sheet for future reference after writing down the master
code . There is NO way of retrieving the master code after it has been programmed in. If you
forget it, you will have to program in a new master code but all other previously programmed
information will remain intact.
Facility Codes: Unique code for transmitter and located on back of transmitter (Fc).
1. Press and the four-digit Master Code.
2. Press for the FIRST facility code.
3. Enter the two-digit facility code (01-10), then press
4. Repeat steps 2and 3to enter additional facility codes.
5. Press TOGETHER to end programming.
1 4 “BEEP”
“BEEP”
“BEEP”
“BEEEEEEEEEP”
1
0
Note: Be sure to increment this number each time another facility code
is entered - up to 10, use 0 for facility code 10 if required.
Transmitter Button Number: Used to identify the individual transmitter button that will activate the receiver (Up to 3 buttons).
1. Press and the four-digit Master Code.
3. Enter the button number that the receiver is to respond to (1-2-3), then press
5. Press TOGETHER to end programming.
3 2 “BEEP”
“BEEP”
“BEEEEEEEEEP”
0
Relay Strike Time: The amount of time the receiver relay activates.
1. Press and the four-digit Master Code.
2. Enter a two-digit number (00-99) for the relay activation in seconds, then press
3. Press TOGETHER to end programming.
0 3 “BEEP”
“BEEP”
“BEEEEEEEEEP”
0
Note: 00 programs the relay for 1/2 second.
01 programs the relay for 1 second etc.
Note: Receivers manufactured before Rev E (2/01) require
the receiver case to be opened to access the master code
button. All other programming steps remain the same for
the receivers.
8
7
0
*
9
#
2
13
5
46
Master Code Button
12345678
Keypad
120 S. Glasgow Avenue
In
g
lewood
,
California 90301 U.S.A.
Programming Continued
805
7-
065
-H-1
0
-14 Copyright 2014 DoorKing, Inc. All rights reserved.
This device complies with the FCC Rules Part 15. Operation is subject to the following two conditions:
1.) This device may not cause harmful interference.
2.) This device must accept and interference received, including interference that may cause undesired operation.
This class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada.
Program Transmitter Codes One at a Time: The five-digit unique code is located on the back of the transmitter (Tr).
1. Press and the four-digit Master Code.
2. Enter the five-digit transmitter code, then press
3. Repeat step 2to enter additional transmitter codes.
4. Press TOGETHER to end programming.
1 0 “BEEP”
“BEEP”
“BEEEEEEEEEP”
0
Delete Transmitter Codes One at a Time: The five-digit unique code is located on the back of the transmitter.
1. Press and the four-digit Master Code.
2. Enter the five-digit transmitter code to be deleted, then press
3. Repeat step 2to delete additional transmitter codes.
4. Press TOGETHER to end programming.
1 2 “BEEP”
“BEEP”
“BEEEEEEEEEP”
0
Delete ALL Transmitter Codes at Once: WARNING: Deleted codes CANNOT be retrieved.
1. Press and the four-digit Master Code.
2. Enter 9999, then press
3. After approximately 25 seconds, a long will be heard to end programming.
1 3 “BEEP”
“BEEP”
“BEEEEEEEEEP”
Program a Group of Transmitter Codes : The five-digit unique codes are located on back of the transmitters (In numeric sequence).
1. Press and the four-digit Master Code.
2. Enter the five-digit transmitter code for the LOWEST number transmitter in the group, then press
3. Enter the five-digit transmitter code for the HIGHEST number transmitter in the group, then press
4. A long tone will be heard when programming is complete.
1 1 “BEEP”
“BEEP”
“BEEP”
“BEEEEEEEEEP”

This manual suits for next models

7

Other DoorKing Receiver manuals

DoorKing 8059 RF User manual

DoorKing

DoorKing 8059 RF User manual

DoorKing MicroPlus Series User manual

DoorKing

DoorKing MicroPlus Series User manual

DoorKing MicroCLICK 8059 User manual

DoorKing

DoorKing MicroCLICK 8059 User manual

DoorKing 8054 MicroPlus Technical specifications

DoorKing

DoorKing 8054 MicroPlus Technical specifications

Popular Receiver manuals by other brands

Clarion DUB278RMP owner's manual

Clarion

Clarion DUB278RMP owner's manual

Avalon RF ODX402 User's guide & operating manual

Avalon RF

Avalon RF ODX402 User's guide & operating manual

Philips DSR2210 Technical specifications

Philips

Philips DSR2210 Technical specifications

Pioneer VSX-D850S Service manual

Pioneer

Pioneer VSX-D850S Service manual

Pioneer PRO-710HD Service manual

Pioneer

Pioneer PRO-710HD Service manual

Pioneer Elite VSX-81TXV-S operating instructions

Pioneer

Pioneer Elite VSX-81TXV-S operating instructions

Projecta EVAPT2T1 manual

Projecta

Projecta EVAPT2T1 manual

Alba STB102XI instruction manual

Alba

Alba STB102XI instruction manual

Eldat RCL03 Series quick start guide

Eldat

Eldat RCL03 Series quick start guide

Yamaha AV Receiver owner's manual

Yamaha

Yamaha AV Receiver owner's manual

FUTABA R6208SB quick start guide

FUTABA

FUTABA R6208SB quick start guide

Denon AVR-985 operating instructions

Denon

Denon AVR-985 operating instructions

DS18 DDX10.5AD owner's manual

DS18

DS18 DDX10.5AD owner's manual

AVANIT SXHD user manual

AVANIT

AVANIT SXHD user manual

Yamaha RX-V350 owner's manual

Yamaha

Yamaha RX-V350 owner's manual

MDN BTR006L user manual

MDN

MDN BTR006L user manual

CYP PUV-1830RX-AVLC manual

CYP

CYP PUV-1830RX-AVLC manual

PEHA 454 FU-E REG Installation and operating instructions

PEHA

PEHA 454 FU-E REG Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.