GB
1. General
1.1 Application
Various electric loads such as incandescant lamps, HV-halogen lamps, electronic
ballast and inductive loads can be switched with the Easyclick receiver.
The receiver is operated with Easyclick transmitters (radio signal). Before use, the
transmitters must be assigned to the receiver (max. 30 receivers). Every transmitter
can control an unlimited number of receivers.
Note: Read through the operating instructions carefully before putting the device
into service.
1.2 Warranty conditions
These operating instructions are an integral part of both the device and our terms
of warranty. They must be handed over to the user. The technical design of the
appliance is subject to change without prior notification. PEHA products are manuf-
actured and quality-checked with the latest technology according to applicable nati-
onal and international regulations. Nevertheless, if a product should exhibit a defect,
PEHA warrants to make remedy as follows (regardless of any claims against the
dealer to which the end-user may be entitled as a result of the sales transaction):
In the event of a justified and properly-established claim, PEHA shall exercise its
prerogative to either repair or replace the defective device. Further claims or liability
for consequential damage are explicitly excluded. A justifiable deficiency is one in
which the device exhibits a structural, manufacturing, or material defect that makes it
unusable or substantially impairs its utility at the time it is turned over to the end-user.
The warranty does not apply to natural wear, unintended usage, incorrect connec-
tion, device tampering or the effects of external influences. The warranty period is
for 24 months from the date of purchase by the end-user from a dealer and ends not
later than 36 months after the device’s date of manufacture. German law shall be
applicable for the settlement of warranty claims.
1.3 Disposal of the device
The device must be disposed of in compliance with the laws and standards of the
country in which it is operated!
2. Safety
CAUTION! Danger of electrical shock!
The housing contains current-carrying components. Contact can
lead to personal injury! All work on the mains network and the device
may only be done by an authorised electrician.
•Disconnectpowersupplyfromthedevicepriortoperforminganyworkonit.
•Securethedeviceagainstbeingpoweredonagain.
•Checkthatthedeviceispoweredoff.
•Closethehousingsecurelybeforeapplyingpower.
The following must be observed:
•Prevailingstatutes,standardsandregulations.
•State-of-the-arttechnologyatthetimeofinstallation.
•Thedevice’soperatinginstructions.
•Operatinginstructionscanonlycitegeneralstipulations.Thesearetobeviewed
in the context of a specific system.
This device is only intended to be used for its stated application. Unauthorised con-
versions, modifications or changes are not permissible!
This device may not be used in conjunction with other devices whose operation
could present a hazard to persons, animals or property.
3. Technical specifications
General data
Transmit frequency 868,3 MHZ
Power supply 230V~ / 50 Hz
Outputs (potential-free) 2 NO contacts
2 Changeover contact
Power line protection Circuit breaker (max. 16 A)
Ambient temperature -20° to +40°C
Storage temperature -40° to +85°C
Test specifications EN 60669-2-1
Identication CE ; KEMA/KEUR
Protection type IP20
Note: The strength of the radio signal between sender and receiver decreases with
increasing distance. The visually unobstructed range is about 30 m in passageways
and 100 m in open rooms. The range can be increased through the use of an Ea-
syclick repeater.
4. Installation and commissioning
4.1 Safety information
Installation and commissioning may only be done by an authorised electrician. Mains
power (230 V ~/50 Hz) to electrical equipment must be switched off during installa-
tion. Applicable laws and standards of the country in which the device is operated
must be observed!
4.2 Installation information
• NEVERinstallEasyclickreceiversinametalenclosureorintheimmediatevicinity
of large metal objects.
•Installationclosetofloorleveloronthefloorisnotrecommended.
4.3 Installation
The receiver is designed for mounting on a 35mm top hat rail acc. EN 50022 in in-/on-
wall distribution housing. The devices can be mounted directly next to each other.
The receiver has 4 potential-free relay contacts. Outputs 1-4are normally open
contacts. Outputs Care normally-closed contacts.
•Installthereceiveratasuitablelocation.
•Protectpowersupplylinewithanautomaticcircuitbreaker(max.F=16A)!
•Installconnectioncablesaccordingtotheconnectiondiagram
4.4 Commissioning
•Switchonpowersupplyafterinstallation.
•Programthereceiver(seePoint5).
Load specifications per output
Load types NO contact 1 – 4Break contact C
Incandescent lamps(Ω) 2300 W 1000 W
HV-halogen lamps 1250 W 500 W
Inductive 600 VA 250 VA
Electronic ballast 3 items 1 item
Range in buildings
Masonry 20 m, through 3 walls max.
Reinforced concrete 10 m, through 1 wall / ceiling max.
Plasterboard / wood 30 m, through 5 walls max.
Caution! The contacts may not be operated at different voltages
(such as 12V DC and 230V AC).
Caution! If the distribution chassis is made of metal, an external antenna
(460 ANT) must be mounted outside the distribution.
N L
Supply connection
230V~ / 50Hz