SAFETY AND INSTALLATION
FOLLOW THESE INSTRUCTIONS CAREFULLY
Proper installation of the Parallel Cable is essential for safe and reliable
operation.
WARNING!
This Parallel Cable Kit must ONLY be used between two identical Inverter
Generators. Never connect cables between two different inverter generators,
this may cause low voltage output, which can permanently damage the
electrical devices connected to the inverter generators. Before use, read and
understand the installation and operation instructions in this manual to
become familiar with how this Parallel Cable Kit works with two Inverter
Generators with parallel ports. Periodically inspect the cables for damage,
replace cable if its insulation is broken or cracked.
INSTALLATION
1) Connect the two parallel connectors (A)
Fig.1 from one cable to the parallel inputs
(B) on the control panel of the first
Inverter Generator.
2) Connect the two parallel connectors
from the other cable to the parallel inputs on the control panel of the second
Inverter Generator.
3) Attach the ground wire (C) Fig.1 to the ground terminal (D) on the control
panel of the first Inverter Generator.
4) Attach the second ground wire to the ground terminal on the control panel
of the second Inverter Generator.