DVDO PrecisionSDI User manual

BY ANCHOR BAY TECHNOLOGIES
Installation Guide
How to install, set up, and use your module
precision
SDI
Serial Digital Interface
DVDO PrecisionSDI™
Serial Digital Interface Video Input Module for
the iScan™ HD/HD+Video Scaling Engine

Introduction 3
Installation and Set-Up 4
Updating your Software 7
Troubleshooting 13
Appendix - Error Codes 14
Warranty Information 15
TABLE OF CONTENTS
DVDO PrecisionSDI™ Video Input Module
Installation Guide

3
Thank you for purchasing the DVDO PrecisionSDI™Serial Digital Interface
Video Input Module. Upgrading your iScan™HD/HD+ for SDI digital video
input capability is simple, and this Installation Guide will step you
through the process.
This installation process is in two parts: hardware and software. For the
hardware installation, you will need a few basic tools, including a Phillips-
head screwdriver and a pair of long-nose pliers. For the software installa-
tion, you will need a PC or laptop computer running the Microsoft
Windows operating system, and this computer must also have an RS-232
serial data port on a 9-pin connector.
Should you have any issues or problems during installation, please
contact your Authorized DVDO Reseller for assistance.
You can also contact DVDO directly for help:
Email: Help@DVDO.com
Toll-Free (USA only): 1-866-423-DVDO
INTRODUCTION

4
• SDI Card
• Bulkhead BNC connector with nut and washer
• Stand-offs (qty. 2)
• BNC-to-BNC Cable
• Hole-plug screws (qty. 2)
• RS-232 serial data cable
1Remove the iScan HD/HD+ top cover. To do this,
a. Remove three screws on each side of the unit.
b. Remove two screws on the top of the unit.
c. Remove one screw at the rear
of the unit.
d. Lift the top cover from the rear of
the unit and set it aside.
2Remove the metal plate
that covers the hole for
the SDI BNC connector.
INSTALLATION AND SET-UP
Installing the PrecisionSDI module into your iScan HD/HD+
Contents
Step 1a Step 1b
Step 2
Step 1c

3Mount the bulkhead BNC connector. (a,b) Then plug the two screwholes
left after the plate removal, with round-head screws from the SDI kit.
4Locate the Expansion
Module connector (40 pin
IDC-type header) on the
Video Input board.
5Locate the mounting holes
to the right of the Expan-
sion Module connector.
6Snap the stand-offs into
each mounting hole.
7 Mount the SDI module
onto the Expansion
Module connector. Make
sure that the stand-offs
are lined up exactly with
the two mounting holes
on the SDI module. Steps 7 & 8
Installation and Set-Up (continued)
Steps 4 & 6
Step 3a Step 3b
Step 3c Step 3d
5

6
8 Make sure the 40-pin con-
nector on the SDI card is
aligned with the connector
on the Video Input board.
9Push the module down to
ensure a proper mate
with the stand-offs.
10 Connect one end of the BNC cable to the SDI module BNC connector.
11 Connect the other end of the BNC cable to the
bulkhead BNC connector inside the enclosure.
12 Mount the top cover back onto the unit.
13 Power up the iScan HD and upgrade the software, if required.*
Step 9
Step 11
Step 10
Installation and Set-Up (continued)
* Only iScan HDs with software versions earlier than 3.4-1.09A require
a software update to support the PrecisionSDI Video Input Module.
The iScan HD+is shipped with software that supports the
PrecisionSDI™ Video Input Module. No software update is necessary.

Display
PC
Serial CableiScan HD
VideoSources
PC
Serial CablePower Adaptor
iScan HD
Power Adaptor
7
The iScan HD firmware can be updated using a PC with a serial port.
We recommend a serial port terminal program called Tera Term Pro
(Version 2.3) that we provide on our website.
What’s needed:
• DB9 Male to Female extension (1:1) Serial Cable
• iScan HD with Power Supply
Set up the iScan HD as shown below.
Bring your PC to your iScan HD and
set up as shown here.
• Connect Serial Port cable between PC and iScan HD.
• Turn the PC and iScan HD on.
UPDATING YOUR SOF TWARE
iScan HD Software Update instructions
Hardware setup
If you have NOT already installed your iScan HD into
your home theater system:
If you HAVE already installed your iScan HD into your
home theater system:
for iScan HD only, see note on page 6

8
The CD that comes with your SDI kit includes the Tera Term Pro software
(teraterm_ext) and the .abt file that is needed to update your iScan HD.
You may want to check the www.dvdo.com website for the latest
software release.
1Double click on ‘tera_term.exe’.
2Click ‘Unzip’.
3This action upzips the program to a temporary folder.
4Click ‘OK’. This starts the Tera
Term Pro setup program.
5Select the preferred lan-
guage and click ‘Continue’.
6Click ‘Continue’ unless an
old version of Tera Term
Pro is currently running.
Software Update (continued)
To install Tera Term Pro on your PC

9
7Click ‘Continue’ to install
Tera Term Pro in the
default Program directory.
8Close this window and click ‘OK’ to exit the setup program.
Make sure that no other program is using the serial port that’s connected
to the iScan HD.
1Run Tera Term
Pro from the
Program Menu.
2Select ‘Serial
Port’ from the
Setup menu.
Software Update (continued)
Using Tera Term Pro

10
3Tera Term Pro has been configured to communicate directly with the
iScan HD through the serial port COM1. See below. Select the correct
COM port if the serial cable is not connected to COM1.
4Click ‘OK.’ Now the serial port
setup is completed.
5Tera Term Pro is now ready
to send the new software file
to the iScan HD.
There are two ways to perform software update: using the Front Panel
buttons or using the remote control and On-Screen Display (OSD).
If the iScan HD has not been installed in your home theater system,
just use the Front Panel buttons as described below.
Using the Front Panel buttons
1Press the Configuration button repeatedly until the display shows
“SWUP” (SoftWare UPdate).
2Press the Up or Down arrow buttons until the display shows “YES”.
3Press the Enter/Exit button to confirm the software update.
4The Front Panel Display will show ‘LOAD’.
Using OSD and Remote Control
1Press Menu button.
2Select Configuration -> Software Update -> Yes.
3Confirm by pressing the Enter button.
4The Front Panel Display will show ‘LOAD’.
Software Update (continued)
Setting up the iScan HD for software update

11
1On the Tera Term window, you will see the following message.
Important Note:
You can still cancel the download operation at this point.
There are two ways to do this.
• Do nothing for about 5 minutes. After this time the iScan HD will
revert back to normal operations with the current software.
• Unplug the power cord from the iScan HD and then plug it back
in again. The iScan HD will revert back to normal operations with the
current software.
2To update the system software select ‘Send File’ from the file menu.
Software Update (continued)
Completing the update process

12
3Make sure Binary mode is selected.
4Locate the ‘.abt’ file to download. Only files with a ‘.abt’ extension
should be loaded. If any other file is loaded, an error will occur.
If this happens see the troubleshooting section.
5Click the ‘Open’ button to send the file.
6 Data is now being transferred to your iScan HD. You should see the
word “BUSY” scrolling on the Front Panel. You will also see the
download status on your PC.
7When the update is complete you will see ‘VRFY’ momentarily dis-
played on the Front Panel Display. This is the iScan HD checking its
software to be sure it is correct. The download process may take up to
5 minutes to complete.
8When the update process is complete, the front panel light will turn
green.
9Your iScan HD with your new PrecisionSDI Input Module upgrade is
now ready to use. To select the SDI input, use the SDI button on the
remote control, or select the SDI input using the front panel button
labeled Input Select.
Software Update (continued)

13
The front panel displays ‘LOAD’ even after cycling the system power
by unplugging the iScan HD and plugging it in again.
If this problem occurs you must load a .abt file into your iScan HD.
Download a .abt file from www.dvdo.com and load it according to
the procedure above steps 4 through 6.
The front panel displays ERR2.
Check to be sure the correct file was chosen. Only files with the .abt
extension are valid for updating the iScan HD.
Once the correct file is located, reset the system by unplugging it
and plugging it in again. You can follow the software update proce-
dure again to update the system with a valid .abt file.
If after making a second attempt and the display still shows ERR2,
check the file to be sure it was not corrupted during download. To
check the file make sure the size of the file is correct. If you are not
sure it is suggested to download the file again.
The front panel displays ERR7.
This error means that the transmission of data to the iScan HD has
been interrupted. This could be caused by the terminal program
being paused or canceled. Another cause of this error is that the
serial port has become disconnected or has a faulty serial cable. If
you have paused the terminal you can just restart it and the down-
load will resume. Otherwise you must cycle the system power by
unplugging it and plugging it in again.
TROUBLESHOOTING

These error codes will appear in the front panel display (FPD) of the iScan HD.
14
APPENDIX A
iScan HD Bootloader Error Codes
FPD shows Type Description Possible causes
ERR0 Unknown Error An unknown error
occured.
1) Software bug.
ERR1 File checksum
error
Wrong checksum
received at the end
of an ASCII file record.
1) Wrong file loaded.
2) Corrupted file
loaded.
ERR2 Bad record type Record in ascii data
is incorrect.
1) Wrong file loaded.
2) Corrupted file
loaded.
ERR3 Flash program
error
Error programming
flash device
1) Wrong file loaded
2) Hardware failure
ERR4 Device 1
checksum error
Calculated checksum for
device 1 does not match
expected checksum
1) Firmware update
interrupted
2) Hardware failure
ERR5 Device 2
checksum error
Calculated checksum for
device 1 does not match
expected checksum
1) Firmware update
interrupted
2) Hardware failure
ERR6 Erase timeout Erasing flash device
took more than
30 seconds
1) Hardware failure
ERR7 Program timeout Programming a byte
in flash took more
than 500ms
1) Hardware failure
ERR8 Buffer empty
timeout
RS232 data buffer
was empty for more
than 500ms
1) RS232 communica-
tion broken.

WARRANTY
Disclaimer
This document is provided for technical informa-
tion for the user. It does not create any warranty
with respect to the product, and does not modify
or enhance the terms of the warranty that may
accompany this product. Anchor Bay Technologies,
Inc. reserves the right to modify the information
in this document as necessary. Anchor Bay
Technologies, Inc. holds no responsibility for any
errors that may appear in this document.
Customers should take appropriate action to
ensure their use of the products does not infringe
upon any patents. Anchor Bay Technologies, Inc.
respects valid patent rights of third parties.
Trademarks
The DVDO® and iScan™ trademarks are licensed
exclusively to Anchor Bay Technologies Inc., in
the United States of America and all other coun-
tries worldwide. All products bearing the ‘DVDO’
and ‘iScan’ trademarks are based upon technolo-
gies, architectures, and product designs originally
created and developed by Anchor Bay Technologies
Inc., Silicon Image Inc., and DVDO Inc. All product
or other names or marks referenced herein are
trademarks or registered trademarks of their
respective owners, and are the properties of their
respective owners, with all rights reserved.
LIMITED ONE-YEAR WARRANTY
Anchor Bay Technologies, Inc. warrants only to the initial purchaser of this product for a
period of one year from purchase from an Authorized DVDO Reseller, that the product will
be free of electrical and mechanical defects that materially affect the product‘s operation as
described in this Product Guide. Anchor Bay Technologies’ sole obligation shall be, at its sole
option, to repair or replace the product with equivalent or better, or to refund the net origi-
nal purchase price.
DISCLAIMER OF WARRANTY
ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
ARE LIMITED TO ONE YEAR FROM PURCHASE; ALL OTHER EXPRESS OR IMPLIED CONDITIONS,
REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF NON-INFRINGE-
MENT, ARE DISCLAIMED. Some jurisdictions do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you. This warranty gives you specif-
ic legal rights, and you may also have other rights, which vary by jurisdiction.
LIMITATION OF LIABILITY
TO THE EXTENT NOT PROHIBITED BY LAW, IN NO EVENT WILL ANCHOR BAY TECHNOLOGIES,
INC. OR ITS SUPPLIERS BE LIABLE FOR ANY LOST REVENUE, PROFIT OR DATA, OR FOR SPE-
CIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE DAMAGES, HOWEVER CAUSED
REGARDLESS OF THE THEORY OF LIABILITY, ARISING OUT OF OR RELATED TO THE USE OF OR
INABILITY TO USE THE PRODUCT, EVEN IF ANCHOR BAY TECHNOLOGIES, INC. HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL ANCHOR BAY TECH-
NOLOGIES, INC.’S LIABILITY TO YOU, WHETHER IN CONTRACT, TORT (INCLUDING NEGLI-
GENCE), OR OTHERWISE, EXCEED THE AMOUNT PAID BY YOU FOR THE PRODUCT. The forego-
ing limitations will apply even if any warranty or remedy provided to you fails of its essen-
tial purpose. Some jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.

Anchor Bay Technologies Inc.
300 Orchard City Drive, M/S 131
Campbell, California 95008
email support@dvdo.com
web www.dvdo.com
toll free 866.423.DVDO
fax 408.379.3845
DVDO PrecisionSDI™
Serial Digital Interface Video Input Module
for the iScan™HD/HD+ Video Scaling Engine
Installation Guide
December 2004
English
Installation Guide version 1.2
ABT P/N 75-0227-03
BY ANCHOR BAY TECHNOLOGIES
Table of contents