easyRAID Q24P2-U4R4 User manual

easyRAID Q24P2-U4R4
Hardware Manual
42-30000-5105
SCSI Channel to Serial ATA II
Disk Array System
Version 1.0


easyRAID Q24P2-U4R4
U320 SCSI Channel to Serial ATA
II
Disk Array System
Hardware User Manual


i
TableofContents
Preface................................................................................................................... i
Chapter1 SystemRequirements
Operating Environment ....................................................................................1
VT100 Terminal Settings ..................................................................................1
Host Interface ...................................................................................................2
Chapter2 BasicConfiguration
Unpacking .............................................................................................................3
Components ..........................................................................................................5
Closed Front Panel ...........................................................................................5
Open Front Panel .............................................................................................6
Disk Tray ..........................................................................................................7
Rear View .........................................................................................................8
Installing Disks ......................................................................................................9
Making Connections ...........................................................................................11
Connecting the Host Interface ........................................................................11
Connecting a network .....................................................................................12
Connecting and Turning on the Power ...........................................................12
Mounting in a Rack .............................................................................................13
Installing the Rail Extenders ...........................................................................14
Chapter3 Maintenance
Replacing a Disk .................................................................................................15
Replacing a Power Supply ..................................................................................16
Upgrading Memory .............................................................................................19
Appendix
Hardware Specifications .....................................................................................21


i
Preface
AboutthisManual
This manual is designed to make the disk array system as easy to use as possible. Information
contained in this document has been checked for accuracy, but no guarantee is given that the con-
tents are correct. Information and specifications are subject to change without notice.
CopyrightNotice
© Copyright 2008
All rights reserved. This disk array system and related documentation are protected by copyright
and are distributed under licenses restricting their use, copying, and distribution. No part of this
documentation may be reproduced in any form by any means without prior written authorization
and its licensors, if any.
Conventions
Caution
This symbol is used to remind users to pay attention to important
descriptions regarding usage and maintenance (repair) or additional
important information related to this disk array system.
Note
This symbol is used to remind users of useful information that can make
procedures such as configuration easier to accomplish.

ii
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
Preface– Important Safety Instructions, Care and Handling
ImportantSafetyInstructions,CareandHandling
Before starting, take a few minutes to read this manual.
Read all of these instructions and save this manual for
later reference.
Protect the disk array system from extremely high or low
temperatures. Let the disk array system warm (or cool)
to room temperature before using it.
Protect the disk array system from being bumped or
dropped. Do not place the disk array system on an
unstable cart, stand, or table. It may fall, causing serious
damage to the product.
Keep the disk array system away from magnetic forces.
Do not use the disk array system near water.
Keep the disk array system away from dust, sand, or dirt.
Gaps and openings in the cabinet are provided for venti-
lation. Never block or cover these openings, because
the disk array system may overheat and become unreli-
able. Don’t place the disk array system on a bed, sofa,
rug, or other similar surface.
Do not place the disk array system near or over a radia-
tor or other heat source.
Refer to the rating plate for the correct voltage and
ensure that the appliance voltage corresponds to the
supply voltage.
V

easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
iii
Preface– Important Safety Instructions, Care and Handling
The appliance must be grounded. The disk array system
is equipped with a 3-wire grounded type of power cord.
This power cord will only fit into a grounded type of
power outlet.
If an extension cord or a power center is used with the
disk array system, make sure that the total current con-
sumption of all products plugged into the wall outlet
does not exceed the ampere rating.
Do not place the disk array system where the cord will
be walked on.
Never push any kind of object into the disk array system
through cabinet gaps and openings, since they may
touch dangerous voltage points and cause a risk of fire
or electric shock.
Unplug the power cord from the wall outlet before clean-
ing. Keep the disk array system dry. Do not use liquid
cleaners, aerosol cleaners, or a wet cloth. Use a damp
cloth for cleaning.
Except as specifically explained in this User Manual, do
not attempt to service the disk array system by yourself.
Opening or removing the covers may expose you to
dangerous voltages.
Unplug this product from the wall outlet and refer servic-
ing to qualified service personnel under the following
conditions.
• If the disk array system has been exposed to
water or any liquid.
• If the disk array system has been dropped or the
cabinet damaged.
Users should not remove the cover.
Disconnect all power supply cords before servicing.
Fan1
Power1
oGGwGGY

iv
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
Preface– Important Safety Instructions, Care and Handling
Placement Notes
• The disk array system LCD panel can be damaged by exposure to
direct sunlight. Limit exposure to subdued or indirect sunlight only.
• The disk array system should be used only in clean environments
that are free from airborne contaminants such as dust, dirt, and
smoke. Excessive moisture or oil particles in the air can also hinder
disk array system performance.
• To reduce the possibility of data errors caused by electromagnetic
interference, locate the disk array system at least five feet away
from electrical appliances and equipment that generates magnetic
fields.
Power Supply Safety Notes
• To avoid electric shocks, do not use an extended power cord or an
outlet that does not match the disk array system plug or leaves the
plug exposed.
• The disk array system has a 3-wire grounded plug. The third pin
connects to ground; do not remove it.
• If the power cord or plug is damaged or worn, unplug it immediately
and contact a qualified service technician for maintenance.
• To avoid fire or electric shocks, do not overload electric power out-
lets.
CAUTION : MULTIPLE POWER SOURCES
Disconnect all AC power cords to completely power from the unit
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
CAUTION
The thumbscrews on the rear surface shall be secured by the screw-
driver, which cannot be loosened by bare hands to prevent the uninten-
tional access to the hazardous parts inside the equipment.

1
1 System Requirements
Ensure that the following requirements are met before installing the disk array system.
Operating Environment
• 15 cm (6-inches) of space around the disk array system for proper ventilation
• ambient temperature of 5°C to 40°C (40°F to 104°F)
• ambient non-condensing relative humidity of 20% to 80%
• dust, smoke, and oil free environment
• no large magnetic fields, such as those generated by a high voltage power cables and
motors, etc.
• no direct sunlight
• a flat, stable surface capable of supporting the disk array system
VT100 Terminal Settings
Refer to the following table for a summary of VT100 terminal settings required to communicate
with the disk array system. Refer to your system manual for instructions on setting up the VT100
terminal settings.
Item Required Setting
Connection Serial Port (COM1 or COM2)
Protocol RS232 (Asynchronous)
Cabling Null Modem cable
Baud Rate 115200
Data Bits 8
Stop Bit 1
Parity None

2
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
1
System Requirements –
Host Interface
The disk array system has dual SCSI interfaces. Refer to the following sections to understand
host interface system requirements.
Small Computer Systems Interface
The easyRAID Q24P2-U4R4 has dual U320 SCSI interfaces that are compatible with previous
SCSI standards. Refer to the following table to understand SCSI bus requirements.
Note
Subtract the internal cable length (30 cm) from the maximum SCSI bus
length to calculate the maximum external SCSI cable length.
SCSI
Standard
Maximum
SCSI Bus Length
in Meters
Data Rate
in Megabytes
per Second
Maximum
Number of Devices
Ultra320 12 320 15
Ultra160 12 160 15
Ultra2 12 80 15
Ultra Wide 1.5 40 7
Fast Wide 3 20 15
Ultra 1.5 20 7

3
2 BasicConfiguration
This chapter describes disk array system connections and disk installation.
Unpacking
Contact your supplier if any of the following items are missing or damaged.
Caution
The disk array system is heavy. Be careful when lifting and moving it.
Item qty
Disk Array System 1 pcs
Hard Disk Tray 24 pcs
Hardware and Software User Manuals 1 set
Rails 1 set
Rail Extenders 1 set
PowerP/SFailAccess
EnterESC
easyRAID Q24P2-U4R4
Ultra320SCSItoSerialATA
DiskArraySystem
HardwareUserManual
PowerP/SFailAccess
EnterESCPri/Sec
easyRAID Q24P2-U4R4
Ultra320SCSItoSerialATA
DiskArraySystem
SoftwareUserManual
PowerP/SFailAccess
EnterESCPri/Sec

4
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
2 Basic Configuration – Unpacking
VHDC to VHDC Ultra320 SCSI Cable 1 pcs
HPD to VHDC Ultra320 SCSI Cable 1 pcs
Terminator VHDC 1 pcs
Front Panel Keys 2 pcs
Power Cables 3 pcs
Screw pack 2 pack
Fix Screw pack M5 2 pack
Fix Scwer pack M6 2 pack
Fix Scwer pack UNC #10-32 2 pack
RS-232 cable 1 pcs
CD-ROM (option) 1 pcs

easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
5
2 Basic Configuration – Components
Components
ClosedFrontPanel
No. Name Description
1LCD panel Displays warning, operating, and configuration
information.
2Power-on indicator Indicates the disk array system power is on.
3Power supply fail indicator Indicates a failed power supply.
4Host computer access indicator Indicates data transfer between the disk array sys-
tem and the host computer.
5Up function button Moves up in the LCD menus.
6Down function button Moves down in the LCD menus.
7Enter function button Selects a menu item or confirms a choice or entry.
8Escape function button Returns to the previous LCD menu without making
changes.
9Lock Locks front cover.
Power P/S Fail Access
Enter ESC
1
34
57
2
68
9

6
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
2 Basic Configuration – Components
OpenFrontPanel
No Name Description
1-24 Disk trays 1-24 Removable hot swap disk trays
25 Front panel door Protects the disks and houses the LCD panel
Disk Mapping
Color Status
Bule Access
Green Disk Online
Red No Disk
Tray LED Indication
1
2
3
4
5
6
7
8
9
10
11
12
13 15 17 19
25
14 16 18 21 23
20 22 24

easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
7
2 Basic Configuration – Components
DiskTray
No. Name Description
1Power/Error indicator LED Different colors indicate different disk states:
• Green – Disk online
• Orange – Disk full
• Red – No disk
2Access indicator LED This blue LED indicates that the disk is being
accessed.
3Tray handle Releases the disk tray.
21
Front
3

8
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
2 Basic Configuration – Components
RearView
No. Name Description
1Cooling fan 1 System cooling fan.
2Ethernet Port Used for browser-based configuration.
3Host Port 2
(Secondary SCSI channel) Connects to the host server.
4Cooling fan 3 System cooling fan.
5Host Port 1
(Primary SCSI channel) Connects to the host server.
6RS-232 Port Connects to a VT100 terminal or equivalent.
7Cooling fan 4 System cooling fan.
8Cooling fan 2 System cooling fan.
9Power Supply Handle For power supply removal.
10 Power Supply 2 Removable redundant power supply 2.
11 Power Supply AC In Connects to a 100-240 VAC power source.
12 UPS port Data port for uninterruptable power supply.
13 Power Supply Handle For power supply removal.
14 Power Supply 3 Removable redundant power supply 1.
15 Power Supply AC In Connects to a 100-240 VAC power source.
16 Power Supply Switch Switches the power on or off.
17 Power Supply Handle For power supply removal.
18 Power Supply 1 Removable redundant power supply 1.
19 Power Supply AC In Connects to a 100-240 VAC power source.
LAN COM
Host Port 2 Host Port 1
P/S 3 P/S 2P/S 1
Fan 1 Fan 3 Fan 4 Fan 2
1
13
823 4 56 7
9101112141516171819

easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
9
2 Basic Configuration – Installing Disks
InstallingDisks
This section describes how to install disks in the disk array system.
1Unlock the front panel door, then pull it open.
2Push the button (A) to release the disk tray handle. Pull the handle (B) to release the tray.
3Align the rear of the disk with the rear of the disk tray.
4Insert the disk into the disk tray and fix into place with screws supplied with the disk.
DiskMapping
Color Status
Bule Access
Green Disk Online
Red No Disk
TrayLED Indication
AB

10
easyRAID Q24P2-U4R4 Serial ATA II Disk Array System
2 Basic Configuration – Installing Disks
5Slide the disk tray back into the empty slot (A), then slowly close the disk tray handle
(B).
6Repeat steps 2 to 5 until all of the required disks have been installed.
7Push the front panel door closed, and lock it.
AB
Disk Mapping
Color Status
Bule Access
Green Disk Online
Red No Disk
Tray LED Indication
Table of contents
Other easyRAID Network Storage Server manuals
Popular Network Storage Server manuals by other brands

HP
HP J3278B - SureStore CD-ROM Server/Tower 7 NAS... Quick setup guide

Thecus
Thecus N16000 series user manual

Synology
Synology DS216play Quick installation guide

SMC Networks
SMC Networks TigerStore SMCNAS04 Specification sheet

Proware
Proware EP-1401-C3A user manual

Western Digital
Western Digital WDBACH0030HAL user manual

Conceptronic
Conceptronic CH3SNAS Grab'n'GO Media Store user manual

Buffalo
Buffalo LINKSTATION HS-DGL Quick setup guide

Digital Watchdog
Digital Watchdog Blackjack NAS quick start guide

NETGEAR
NETGEAR RNDP600E - ReadyNAS Pro Pioneer Edition NAS... installation guide

Western Digital
Western Digital Sentinel DX4000 Administrator's guide

Thecus
Thecus 1U4500R user manual