Ebyte E103-W05 User manual

E103-W05 User Manual
W600 20dbm WIFI Module

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
1
Contens
1. OVERVIEW.............................................................................................................................................................2
1.1 BRIEF INTRODUCTION.................................................................................................................................................. 2
1.2 FEATURES..................................................................................................................................................................... 2
1.3 APPLICATIONS ............................................................................................................................... 2
1.4 CONNECTION MODE.....................................................................................................................................................3
1.5 PARAMETERS................................................................................................................................................................ 3
1.6 ELECTRONIC PARAMETERS...........................................................................................................................................4
2. HARDWARE PARAMETERS...............................................................................................................................5
2.1 PIN DEFINITION............................................................................................................................................................ 5
2.2 POWER CONSUMPTION.................................................................................................................................................6
2.3 DIAGRAM..................................................................................................................................................................... 6
3. QUICK START........................................................................................................................................................7
3.1 BEFORE TESTING..........................................................................................................................................................7
3.2 STEPS FOR MODULE TO WORK IN AP MODE AS TCP SERVER...................................................................................... 8
3.2.1 Brief Introduction................................................................................................................................................. 8
3.2.2 Network model..................................................................................................................................................... 8
3.2.3 Setting...................................................................................................................................................................8
3.3 STEPS FOR MODULE TO WORK IN STA MODE AS TCP CLIENT.................................................................................. 11
3.3.1 Brief Introduction............................................................................................................................................... 11
3.3.2 Network model................................................................................................................................................... 11
3.3.3 Setting.................................................................................................................................................................12
3.4 GUIDE FOR AIRKISS APP FOR ANDROID.................................................................................................................... 15
3.4.1 APP Setting.........................................................................................................................................................15
3.4.2 WIFI RF Setting Software Setting......................................................................................................................16
3.5 GPIO SETTING........................................................................................................................................................... 16
3.5.1 AT+CIOMODE to Set GPIO working mode......................................................................................................16
3.5.2 AT+CIOWRITE to set GPIO Level....................................................................................................................17
3.5.3 AT+CIOREAD to Read GPIO Level..................................................................................................................17
3.5.4 Pin AT Command Example................................................................................................................................ 17
3.6 SERIAL PORT BAUD RATE SETTING............................................................................................................................. 18
4. NOTICE................................................................................................................................................................. 19
4.1 RELATION OF AP,STA AND SERVER CLIENT...........................................................................................................19
4.2 TRANSPARENT TRANSMISSION................................................................................................................................... 19
4.3 MAXIMUM NUMBER OF AP CONNECTIONS AND SERVER CONNECTIONS.................................................................... 19
4.4 AT COMMAND............................................................................................................................................................20
5. HARDWARE NOTICE........................................................................................................................................ 20
6. FAQ......................................................................................................................................................................... 21
6.1 COMMUNICATION RANGE IS TOO SHORT.................................................................................................................. 21
6.2 MODULE IS EASY TO DAMAGE................................................................................................................................. 21
6.3 BIT ERROR RATE IS TOO HIGH.................................................................................................................................. 21
7. REVISION HISTORY..........................................................................................................................................22
8. ABOUT US............................................................................................................................................................. 22

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
2
1. Overview
1.1 Brief introduction
E103-W05 is a cost-effective 100mW (20dBm) wifi module. It works in the
2.4~2.483GHz frequency band, the module is small, has an onboard PCB antenna and
low power consumption, and the data transmission is fast. The module can use the
serial port to send and receive data and use AT commands to set parameters which are
mostly compatible with the E103-W01 module. Both former and new users can
quickly use it, making it a good data transmission partner in IoT applications.
The E103-W05 module was developed by Ebyte based on the WinnerMicro
W600 chip. The module integrates transparent transmission function, ready to use,
supports serial AT command set, server AT command set, users can use the Internet through the serial port. This module
is widely used in IoT applications such as smart appliances, smart homes, wireless audio and video, smart toys, medical
monitoring, industrial control, etc.
1.2 Features
Support transparent transmission at boot, automatic connection when disconnected
Support multiple baud rates
Support SmartConfig configuration function
Support TCPServer, TCPClient, UDP
Three working modes STATION, AP, STATION&AP
Support 14mA low power data reception
Support serial port transparent transmission
Support multiple encryption methods
Support module serial AT command configuration
Built-in watchdog, never crash
Parameter memory, save after power off
1.3 Applications
Wireless meter reading
Wireless sensing
Smart home
Industrial remote control and telemetry
Intelligent buildings and intelligent buildings
High-voltage line monitoring
Environmental Engineering
Highway

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
3
Small weather station
Automated data collection
Consumer Electronics
smart robot
Street light control
1.4 Connection Mode
NO.
Connection
Description
0
Module to
Module
Module 1 is set to AP mode as a TCP or UDP server. Module 2 is set
to STATION mode and connected to AP No. 1 for communication,
through TCP or UDP Client mode.
1
Module to
Server
The Wi-Fi module is connected to the Internet through a wireless
router, and communicates with servers on the network (LAN or
Internet) via TCP Client or UDP. To connect to the Internet server,
users need to configure the correct port mapping on the wireless
router.
2
Module to
Client
The Wi-Fi module connects to the Internet through a wireless router
to establish a TCP or UDP Server to listen for connection signals. The
Client module communicates with the module server by connecting to
it.
For more usage methods, please refer to Section 5 Networking Instructions.
1.5 Parameters
No.
Name
Value
Note
1
RF chip
W600
Beijing WinnerMicro
2
Dimensions
19*13*0.8mm
(L*W*H)
3
PCB process
2 layers
Impedance debugging
4
Working frequency
2.4~2.4835 GHz
-
5
Production Process
Immersion gold process, half
hole process, machine SMT
Wireless products must be machine-attached
to ensure batch consistency and reliability
6
Interface Type
1.27mm
Stamp hole
7
Supply voltage
3.0 ~ 3.6V DC
Voltage higher than 3.6V will cause
permanent damage to the module
8
Communication level
3.6(max)
The voltage difference should be less than
0.3V to reduce power consumption
9
Tested range
100m
open and clear sky, no obstacles, maximum
power, antenna height 1.6m
10
Transmit power
20dBm
100mW
11
AT support
Built-in intelligent processing
Can be read by AT command
12
Wi-Fi version
802.11 b/g/n
-
13
Communication
Interface
UART serial port
-
14
RF interface
PCB onboard antenna
50Ω characteristic impedance
15
Operating temperature
-40 ~ +85℃
Industrial grade
16
Working humidity
10% ~ 90%
Relative humidity, no condensation
17
Storage temperature
-40 ~ +125℃
Industrial grade
18
product weight
0.8±0.1g
-

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
4
1.6 Electronic Parameters
Para.
Condition
Min
Typical
Max
Unit
Storage temperature
range
-
-40
Normal
temperature
125
℃
Welding temperature
IPC/JEDECJ-STD-
020
-
-
260
℃
working Voltage
-
3.0
3.3
3.6
V
Any IO
VIL/VIH
-
-0.3/0.75VIO
-
0.25VIO/3.6
V
VOL/VOH
-
N/0.8VIO
-
0.1VIO/N
IMAX
-
-
-
12
mA
Electrostatic discharge
(human body model)
TAMB=25℃
-
-
2
KV
Electrostatic discharge
(machine model)
TAMB=25℃
-
-
0.5
KV

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
5
2. Hardware Parameters
2.1 Pin Definition
Pin No.
Name
I/O
Function
1
GND
P
GND pin
2
GND
P
GND pin
3
VCC
P
Power supply VDC: 3.0V-3.6V (above 350mA)
4
PA0/GPIO0
IO
I/O pins
5
PA1/GPIO1
IO
I/O pins
6
PA4/GPIO4/TX
O
TXD pin, used as UART serial port output pin, support AT command
7
PA5/GPIO5/RX
I
RXD pin, used as UART serial input pin, support AT command
8
PB13/GPIO13
IO
I/O pins
9
PB14/GPIO14
IO
I/O pins
10
PB15/GPIO15
IO
I/O pins
11
PB16/GPIO16
IO
I/O pins
12
PB17/GPIO17
IO
I/O pins
13
PB18/GPIO18
IO
I/O pins
14
PB6/GPIO6
IO
I/O pins
15
PB7/GPIO7
IO
I/O pins
16
PB8/GPIO8
IO
I/O pins
17
PB9/GPIO9
IO
I/O pins
18
PB10/GPIO10
IO
I/O pins
19
PB11/GPIO11
IO
I/O pins

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
6
20
PB12/GPIO12
IO
I/O pins
21
WAKE
I
Wake up pin, high level will wake up the chip to work
22
RST
I
Reset pin, low level will reset
I = input, O = output, P = power
2.2 Power Consumption
Mode
Min
Typical
Max
Unit
Tx802.11b,CCK 11Mbps,POUT=+19dBm
-
230
-
mA
Tx802.11g,OFDM 54Mbps,POUT=+13.5dBm
-
210
-
mA
Tx802.11n,MCS7,POUT=+12dBm
-
210
-
mA
IEEE802.11b/g/n receivig
-
100-110
-
mA
Sleep
-
0.9
-
mA
Deep Sleep
-
12
-
uA
2.3 Diagram

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
7
3. Quick Start
The E103-W05 module is simple, easy to use, and easy to access the network. It is compatible with most AT
commands of E103-W01 so that it can use E103-W01 controller to easily set the parameters of E103-W05. Users can
refer to several working modes of the module to use the module: module to module, module to server, module to client.
When configuring the parameters of the module, the user first needs to ensure that the operating voltage of the
module is 3.0~3.6V (typical value is 3.3V), and then confirm that the serial port pins have been correctly connected with
the relevant serial port tools and can communicate normally.
3.1 Before Testing
Hardware needed:
1
E103-W05 model Wi-Fi module
2
E103-W05 model Wi-Fi module test board
3
one PC
4
1 router (can be replaced by mobile Wi-Fi hotspot)
The software Needed (with download link)
1
AccessPort/XCOM serial debugging tool
2
TCP&UDP test tool
3
"AirkissDebug" APP for Andriod
4
E103-W05 software

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
8
3.2 Steps for Module to work in AP mode as TCP server.
3.2.1 Brief Introduction
1. The user searches the hot spot of the E103-W05 module through the computer and connects to it.
2. The user establishes a TCP Client on the PC and connects to the listening port of the module TCP Server to achieve
communication.
3.2.2 Network model
3.2.3 Setting
A. Open the E103-W01 configuration software, select the serial port number(1) and baud rate(2) (default 115200), query
the version information(3), and check whether the receiving box(4) has version-related data. If there is, it means that the
communication is normal. As shown below:

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
9
B. Set the working mode of the module to AP, and set the relevant AP parameters, such as AP name, password,
encryption method, channel number, etc.
C. After the setting is successful, we can search through the WIFI in the lower right corner of the computer to search out
our module and connect it.

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
10
D. When connected, the module will display the following information, the MAC address of the access STA and the
assigned IP address.
E. Now we create a TCP Server in the module, listening port

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
11
F. We establish a client on the PC and connect the client of the module, and then can send data. Here, if the server needs
to send data to the client, it can be sent by the AT+CIPSEND instruction. Here users can download the AT instruction
manual of E103-W05 in the data download.
3.3 Steps for Module to work in STA mode as TCP Client.
3.3.1 Brief Introduction
We use the E103-W05 module as the STA working mode to search for nearby WIFI and connect it. At the same time, the
computer is also connected to the same WIFI, so that the E103-W05 and the computer are in the same local area network.
Create a TCP Client on the module side and create on the computer side TCP server, and then communicate.
3.3.2 Network model

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
12
3.3.3 Setting
A. Set the module to STA mode and connect to the relevant WIFI hotspot (router). When the connection is successful,
the following information is received in the data box. At this time, we can query the assigned IP information through IP
information query.
B. Connect our computer to the same wifi as the module and keep them in a local area network.

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
13
C. Create a server on the computer and listen to the relevant port.
D.Set up the module and connect to the server. When the connection is successful, the receiving box has the following
prompt information.

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
14
E.After successfully connecting to the server, we can communicate data between the server and the client, but here, in
order to achieve simple transparent transmission of data, we also need to make some settings to enter the transparent
transmission mode, so that we can avoid specifying each time you send data Awkward operation of width. After the
client connects to the server, perform the following operations to enter transparent transmission.
⑥. Transparent Data Transceiving.

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
15
3.4 Guide for Airkiss APP for Android
The E103-W05 module has a smart network configuration function. Users can use this function to configure the module
to connect to the network quickly. When the module is in STA mode, click SmartC Open to enter the one-key network
configuration mode. If the matching is successful, the module will access the same target WIFI as the mobile phone
without entering the password and SSID.
3.4.1 APP Setting
Installed the Airkiss App on a Android Phone.

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
16
3.4.2 WIFI RF Setting Software Setting
We click SmartC Open on the host computer to start the network configuration. After the configuration is successful, the
module is connected to the same WIFI as the mobile phone, and the following information will be printed in the
receiving box.
3.5 GPIO Setting
In E103-W05, GPIO0/1/6/7/8/9/10/11/12/13/14/15/16/17/18 are used for general GPIO, when we want to open the control by AT
command When reading the output level of the relevant pin, or reading the status of the relevant level, we can use the following
command:
3.5.1 AT+CIOMODE to Set GPIO working mode
Command Format:
AT+CIOMODE =<pin>,<mode>
<pin>: Pin label;
<mode>: working mode;
1: output mode
0: input mode

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
17
3.5.2 AT+CIOWRITE to set GPIO Level
Command Format:
AT+CIOWRITE=<pin>,<level>
<pin>: Pin label;
<mode>: working mode;
1: output mode
0: input mode
3.5.3 AT+CIOREAD to Read GPIO Level
Command Format:
<pin>: Pin label;
3.5.4 Pin AT Command Example
1.Use GPIO18 as output and output low level
AT+CIOMODE=18,1
AT+CIOWRITE=18,0
②. Use GPIO18 as input and read the level
AT+CIOMODE=18,0
AT+CIOREAD=18
The module replies as follows:

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
18
3.6 Serial port baud rate setting
E103-W05 supports the following baud rates:
2000000,1500000,1250000,1000000,921600,406800,230400,115200,57600,38400,19200,9600,4800,2400,
1800,1200,600;
In the setting software, we only provide 115200 and 9600 buttons. For other braud rate, users can use related AT
commands to set, and the settings will take effect immediately.

Chengdu Ebyte Electronic Technology Co., Ltd E103-W05 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
19
4. Notice
4.1 Relation of AP,STA and Server Client
In the process of two network access examples in 3.2 and 3.3 above, it is not only in AP mode that users can establish
TCP Server. Similarly, it is not only when the module is in the STA mode that the user can establish a TCP Client. AP
and STA are just a working mode for the module to access the network. TCP Server, TCP Client and UDP can create the
network chain in any mode of the module.
4.2 Transparent Transmission
The transparent transmission mode can be used only when the module works in TCP Client and UDP. The TCP Server
cannot enter the transparent transmission mode. After entering the transparent transmission mode, you must remember to
manually use AT+CIPSEND to activate the transparent transmission. For transparent transmission, you need to make
relevant settings in the following interface;
4.3 Maximum number of AP connections and server connections
When setting up TCP Server and TCP Client, pay attention to the options of opening and closing multiple connections;
When the module is used as an AP, it can be connected by at most 5 STAs. When the module works in TCP Server mode,
it can be connected by at most 5 TCP Clients. Therefore, customers are recommended to use it when performing short
packet data or not considering packet loss. UDP performs related communications.
Other manuals for E103-W05
1
Table of contents
Other Ebyte Network Card manuals
Popular Network Card manuals by other brands

Samil Power
Samil Power UL3-10K WIFI user manual

Toshiba
Toshiba RemotEye III user manual

Silicon Graphics
Silicon Graphics Ethernet Card user guide

Fn-Link
Fn-Link F89FTSM13-W3 user manual

National Instruments
National Instruments Network Adapter NI PXIe-6672 user manual

EverAccess
EverAccess EA-LAN1 instruction manual